KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
2 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer augmentation in a circular tube with winglet vortex generators(2015-04-01) ;Chokphoemphun, Suriya ;Pimsarn, Monsak ;Thianpong, ChinarukPromvonge, PongjetThe article presents the influence of winglet vortex generators (WVGs) placed in the core flow area on thermal performance enhancement of a tube heat exchanger. The experiment was carried out in a uniform wall heat-fluxed tube by varying turbulent airflow for Reynolds number ranging from 5300 to 24000. In the present work, the WVGs with an attack angle of 30° were inserted into the test tube at four different winglet pitch ratios (R<inf>P</inf> = P/D) and three winglet-width or blockage ratios (R<inf>B</inf> = e/D). The experimental results at various R<inf>P</inf> and R<inf>B</inf> values were evaluated and compared with those for smooth tube and tubes with twisted tape or wire coil. The measurement reveals that the WVGs enhance considerably the heat transfer and friction loss above the plain tube, wire coil and twisted tape. The Nusselt number and friction factor increase with the increment of R<inf>B</inf> and Re but with the decreasing R<inf>P</inf>. The average Nusselt numbers for the WVGs with various R<inf>B</inf> are in the range of 2.03-2.34 times above the plain tube. The thermal performance for the WVGs is found to be much higher than that for the wire coil and twisted tape and is in a range of 1.35-1.59. Also, a numerical investigation is conducted to study the flow structure and heat transfer enhancement mechanisms in the winglet-inserted tube. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer augmentation in a round tube with 60° winglet pair inserts(2014-01-01) ;Chokphoemphun, Suriya ;Tongyote, Pattarapan ;Promvonge, Pongjet ;Jedsadaratanachai, WithadaChompookham, TeerapatThe experimental study on heat transfer enhancement in a tubular heat exchanger fitted with 60o winglet pairs is carried out by varying airflow velocity in turbulent region in the test section having a constant wall heat-flux. Effects of three blockage ratios (BR=e/D= 0.1, 0.15 and 0.2) and three pitch ratios (PR=P/D= 1, 1.5 and 2) of the winglet pairs on heat transfer rates in the terms of Nusselt number (Nu) and pressure loss in the form of friction factor (f) are examined. The experimental results illustrated that the tube with winglet pair insert provides the heat transfer rate higher than the smooth tube around 1.7 to 2.6 times, depending upon operating conditions. The thermal enhancement factor for using the winglet-pair turbulator is in a range of 1.03 - 1.31. © (2014) Trans Tech Publications, Switzerland.
