KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/kmitl/1
Browse
3 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, THz frequency generation using Gaussian pulse for medical applications(2013-03-01) ;Afroozeh, A. ;Innate, K. ;Ali, J.Yupapin, P. P.We propose a new design of THz frequency carrier generation for medical applications. The dense wavelength division multiplexing can be generated by using a Gaussian pulse propagating within a modified PANDA ring resonator and add-drop filter. Results obtained have shown that broad region of frequency band can be obtained between 30 and 100 THz. This area of frequency band can be useful for medical applications, in which the broad bandwidth of THz signals can be obtained and available for medical applications, for instance, the use of Terahertz pulse imaging (TPI) and signal transduction therapy, especially, for blood vessel extraction are discussed. © 2012 Elsevier GmbH. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Molecular diagnosis using multi drug delivery network and stability(2011-12-01) ;Jalil, M. A. ;Innate, K. ;Suwanpayak, N. ;Yupapin, P. P.Ali, J.By using a pair of tweezers to generate the intense optical vortices within the PANDA ring resonator, the required molecules (drug volumes) can be trapped and moved dynamically within the molecular bus networks, in which the required diagnosis or drug delivery targets can be performed within the network. The advantage of the proposed system is that the proposed diagnostic method can perform within the tiny system (thin film device or circuit), which can be available for a human embedded device for diagnostic use. The channel spacing of the trapped volumes (molecules) within the bus molecular networks can be provided. © 2011 Informa Healthcare USA, Inc. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Molecular network topology and reliability for multipurpose diagnosis.(2011-01-01) ;Moongfangklang, N. ;Jalil, M. A. ;Innate, K. ;Mitatha, S.Ali, J.This investigation proposes the use of molecular network topology for drug delivery and diagnosis network design. Three modules of molecular network topologies, such as bus, star, and ring networks, are designed and manipulated based on a micro- and nanoring resonator system. The transportation of the trapping molecules by light in the network is described and the theoretical background is reviewed. The quality of the network is analyzed and calculated in terms of signal transmission (ie, signal to noise ratio and crosstalk effects). Results obtained show that a bus network has advantages over star and ring networks, where the use of mesh networks is possible. In application, a thin film network can be fabricated in the form of a waveguide and embedded in artificial bone, which can be connected to the required drug targets. The particular drug/nutrient can be transported to the required targets via the particular network used.
