Item type:Publication, Simulation and experiment of microheater for a microfluidic polymerase chain reaction device(2004-12-01) ;Klaitabtim, Don ;Lomas, Tanom ;Wisitsora-At, AnuratTuantranont, AdisornIn this paper, we describe the simulation and experimental results of electroplated microheater for microfluidic-base polymerase chain reaction (PCR) device. This work used finite element analysis to simulate the temperature characteristics of a PCR device. The device consists of a reaction chamber using polydimethysiloxane (PDMS) with encapsulated micrhearter made of a nickel resistor wire. Design of the microheater mask layout using Tanner L-edit. Microheater can be made by low cost electroplating process. The temperature in the experiment was shown heating and cooling rates were 0.9°C/s and 0.8°C/s respectively. The thermal distribution of the device was also studied through finite elements modeling then compare to the experimental results. © 2004IEEE.