KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
2 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, The Development of An Adjustable Low-pass Filter for A Partial Discharge Detection System under Testing with The Power Frequency Converter(2019-09-01) ;Leelachariyakul, BanyatYutthagowith, PeerawutIn this paper presents the partial discharge detection system based on the power frequency converter as a low-voltage source and an adjustable low-pass filter which is constructed from variable inductor and fixed capacitor. The inductance is able to vary in the range of 8.69 mH to 18.82 mH. This adjustable low-pass filter circuit in partial discharge detection system is able to filter the undesired harmonic voltage and also reduce background noise. It is compatible with partial discharge detection system for high voltage equipment. The background noise of the commercial partial discharge detection system and the total harmonic distortion (THDv) of the testing voltage are improved. The results show that this low-pass filter that had been designed and constructed is capable for filtering the noise from a power frequency converter in the PD test and the undesired harmonic voltage sufficiently. The quality of the testing high voltage is good and sufficient for testing equipment such as potential transformers. Thus, application of this particular adjustable low-pass filter with variable cut-off frequency to the power frequency converter is a promising approach for generation of an AC sinusoidal voltage for the partial discharge detection system. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, The performance of a high frequency current transducer for partial discharge measurement under testing with a power frequency converter(2018-11-01) ;Leelachariyakul, Banyat ;Paophan, Busayapol ;Chaisiri, PunyaveeYutthagowith, PeerawutIn this paper, the performance of a high-frequency current transducer (HFCT) for partial discharge measurement under testing with a power frequency converter is presented. The performances of the HFCT in comparison with the conventional partial discharge detection system (Omicron MPD600) were investigated terms of the ability to classify partial discharges and the background noises in the system from PD test cells in case of corona discharge, internal discharge and surface discharge. It's found that the presented system provides the better performances (in terms of the background noise) than conventional PD detection system and it can also be used to distinguish type of partial discharges. In addition, the presented system has been used for the real partial test on the PD test cells successfully. The HFCT for PD detection is an attractive choice in the PD tests of high-voltage equipment.
