KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/kmitl/1
Browse
4 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Development of a Tannic Acid-Gelatin Modified Filter Paper Membrane for Trace Lead Detection in Water(2026-06-16) ;Rattanadechawan, Arinrada; ;Mantim, Thitirat ;Donpudsa, SuchaoKaruwan, ChanpenA novel membrane-based solid-phase extraction (SPE) device was developed using cellulose filter paper modified with a tannic acid–gelatin (TA/GE) composite for the preconcentration of lead (Pb(II)) ions from aqueous samples. The TA/GE sorbent layer was fabricated via cross-linking gelatin with tannic acid at pH 9, forming a stable, partially insoluble network that enhances the membrane’s mechanical strength and ion-binding capability. Characterization by SEM confirmed the successful modification, while micro-XRF analysis demonstrated the membrane’s effective adsorption and elution of Pb(II). After preconcentration, square wave anodic stripping voltammetry (SWASV) was used for quantitative determination. The method exhibited linear range of 10–100 μg·L<sup>–1</sup>, with a limit of detection (LOD) of 2.7 μg·L<sup>–1</sup>. Method validation using a certified reference material for trace metals in water produced a combined measurement uncertainty (U) of 9 μg·L<sup>–1</sup> at the 95% confidence level for a sample containing 61 μg·L<sup>–1</sup> Pb(II), showing no significant deviation from the certified value. The developed method was further applied to drinking water and river water samples, achieving recoveries of 82–110% for spiked samples. These results confirm that the TA/GE-modified membrane provides a simple, low-cost, and environmentally friendly platform for trace Pb(II) analysis, with performance meeting both WHO (10 μg·L<sup>–1</sup>) and Thailand Pollution Control Department (50 μg·L<sup>–1</sup>) regulatory standards for drinking and surface water. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis(2023-02-01) ;Somboonsuk, Thachkorn ;Saetear, Phoonthawee ;Mantim, Thitirat ;Ratanawimarnwong, NuanlaorWilairat, PrapinThis work presents the use of a transparent ‘Cross Injection Analysis’ (CIA) platform as a flow system for chemiluminescence (CL) measurements. The CL-CIA flow device incorporates introduction channels for samples and reagents, and the reaction and detection channels are in one acrylic unit. A photomultiplier tube placed above the reaction channel detects the emitted luminescence. The system was applied to the analysis of (i) Co(II) via the Co(II)-catalyzed H<inf>2</inf>O<inf>2</inf>-luminol reaction and (ii) paracetamol via its inhibitory effect on the catalytic activity of Fe(CN)<inf>6</inf><sup>3−</sup> on the H<inf>2</inf>O<inf>2</inf>-luminol reaction. A linear calibration was obtained for Co(II) in the range of 0.002 to 0.025 mg L<sup>−1</sup> Co(II) (r<sup>2</sup> = 0.9977) for the determination of Co(II) in water samples. The linear calibration obtained for the paracetamol was 10 to 200 mg L<sup>−1</sup> (r<sup>2</sup> = 0.9906) for the determination of pharmaceutical products. The sample throughput was 60 samples h<sup>−1</sup>. The precision was ≤4.2% RSD. The consumption of the samples and reagents was ca. 170 µL per analysis cycle.1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Microfluidic paper-based analytical device for determination of sucrose in sugarcane juice using Benedict’s reagent(2022-11-01) ;Ratanawimarnwong, Nuanlaor ;Suksomphot, Vanlada ;Sornpipatpong, Khemika ;Lengwan, SupamitDonpudsa, SuchaoThis work presents a microfluidic paper-based analytical device (μPAD) for the determination of sucrose using the Benedict’s test. An asymmetric dumbbell-shaped hydrophobic barrier was produced by rubber stamping the barrier pattern onto a laboratory filter paper. Hydrochloric acid and solution containing sucrose were successively deposited onto the sample reservoir of the μPAD attached to a glass slide. The device was placed in a plastic bag and dipped into boiling water for accelerating the hydrolysis of sucrose into the reducing sugars. Then the Benedict’s reagent was added at the narrow straight channel connecting the two circular zones of the μPAD, which was replaced in the plastic bag and heated again for reduction of Cu(II) by the reducing sugars. Precipitate of brick-red copper(I) oxide was formed. The image of the μPAD was recorded by a smartphone. The ratio of the red to blue intensities gave linear correlation with the concentration of sucrose in the range of 0.5–10% w/v. The relative standard deviation of the measurement was less than 5% for 2 and 4% w/v sucrose (n = 10), with limit of determination, calculated using standard deviation of regression divided by slope of calibration, of 0.26% w/v sucrose. The method was successfully validated using the dinitrosalicylic acid method for sucrose measurement. Percent recoveries of sucrose were evaluated using ten sugarcane samples. The recoveries were in the range of 89 to 101%, demonstrating that there were no significant sample matrix effects on the quantification.1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Reagent-free analytical flow methods for the soft drink industry: Efforts for environmentally friendly chemical analysis(2012-10-25) ;Mantim, Thitirat ;Saetear, Phoonthawee; ;Chan-Eam, SumonmarnSereenonchai, KamonthipThe evolution of an entirely green analytical system for industrial quality control of carbonated drinks is described. The developed flow system is capable of providing analytical data of the dissolved CO <inf>2</inf>, sucrose, and color of a sample consecutively in real-time. The system has been carefully designed on the basis of "reagent-free", meaning that no added chemicals are required for the analysis. The system first vaporizes CO <inf>2</inf> from the soft drink in a gas-liquid separation chamber, with a channel for a flow of pure water as the CO <inf>2</inf> acceptor. The dissolved CO <inf>2</inf> alters the conductivity of the water stream, which is directly related to the concentration of CO <inf>2</inf> in the soft drink. The sucrose content is measured based on the "schlieren effect", the sample plug flows out of the vaporization chamber into a colorimeter with a near-infrared/light-emitting diode (NIR/LED) as light source. The schlieren effect arises at the boundary of pure water and soft drink with refraction of light in proportion to the sugar concentration. The system also measures the absorbance of the sample using an RGB-LED. The related principles and preliminary experiments as proof of concept are described as well as the construction of the flow system for this completely reagent-free analyzer. A simple flow injection system using the schlieren effect was also developed for rapid quantitative analysis of sugar in noncarbonated soft drinks. © 2012 IUPAC.1
