KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
11 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Rapid Detection of Perfluorooctanesulfonic Acid Using Surface-Enhanced Raman Spectroscopy and Deep Learning(2025-10-07) ;Juhong, Aniwat ;Li, Bo ;Liu, Yifan ;Yao, Cheng YouYang, Chia WeiPer- and polyfluoroalkyl substances (PFAS) are a large group of human-made chemicals that have been widely used in industry and consumer products. Perfluorooctanesulfonic acid (PFOS) is a ubiquitous type of PFAS, which is extremely stable chemicals that have been persistent in the environment for many years. The accumulation of PFOS in the human body can lead to various unfavorable health issues related to the immune, metabolic, and endocrine systems. The conventional PFOS detection method utilizes liquid chromatography coupled with a mass spectroscopy system that typically involves a lengthy and complex procedure. Herein, we propose to develop a low-cost and rapid test approach based on surface-enhanced Raman spectroscopy (SERS) and deep learning for PFOS detection. The gold nanoparticle SERS substrates utilized in this study can significantly enhance the Raman signal of PFOS in solution at a low concentration. PFOS detection and quantification in water using the SERS-based substrate are carried out by measuring Raman peak intensities of PFOS in solution at a range of low concentrations and comparing them to the signal of a blank SERS substrate background. The results show that the SERS substrate can achieve a detection limit as low as 0.0005 ppb. In addition, we propose a demultiplexing deep learning model, which can generate high signal-to-noise ratio (SNR) PFOS spectra from the noisy mixture of PFOS and background Raman spectra. Average cross-correlation and mean absolute error (MAE) are utilized to evaluate the similarity between the demultiplexed and denoised PFOS Raman spectra (output of deep learning) and their ground truths. The proposed model can achieve an encouraging result with high average cross-correlation and low average MAE of 0.9622 ± 0.0667 and 0.0034 ± 0.0024, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Monocular depth estimation based on deep learning for intraoperative guidance using surface-enhanced Raman scattering imaging(2025-02-01) ;Juhong, Aniwat ;Li, Bo ;Liu, Yifan ;Yao, Cheng YouYang, Chia WeiImaging of surface-enhanced Raman scattering (SERS) nanoparticles (NPs) has been intensively studied for cancer detection due to its high sensitivity, unconstrained low signal-to-noise ratios, and multiplexing detection capability. Furthermore, conjugating SERS NPs with various biomarkers is straightforward, resulting in numerous successful studies on cancer detection and diagnosis. However, Raman spectroscopy only provides spectral data from an imaging area without co-registered anatomic context. This is not practical and suitable for clinical applications. Here, we propose a custom-made Raman spectrometer with computer-vision-based positional tracking and monocular depth estimation using deep learning (DL) for the visualization of 2D and 3D SERS NPs imaging, respectively. In addition, the SERS NPs used in this study (hyaluronic acid-conjugated SERS NPs) showed clear tumor targeting capabilities (target CD44 typically overexpressed in tumors) by an ex vivo experiment and immunohistochemistry. The combination of Raman spectroscopy, image processing, and SERS molecular imaging, therefore, offers a robust and feasible potential for clinical applications. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Multihead Attention U-Net for Magnetic Particle Imaging–Computed Tomography Image Segmentation(2024-10-01) ;Juhong, Aniwat ;Li, Bo ;Liu, Yifan ;Yang, Chia WeiYao, Cheng YouMagnetic particle imaging (MPI) is an emerging noninvasive molecular imaging modality with high sensitivity and specificity, exceptional linear quantitative ability, and potential for successful applications in clinical settings. Computed tomography (CT) is typically combined with the MPI image to obtain more anatomical information. Herein, a deep learning-based approach for MPI-CT image segmentation is presented. The dataset utilized in training the proposed deep learning model is obtained from a transgenic mouse model of breast cancer following administration of indocyanine green (ICG)-conjugated superparamagnetic iron oxide nanoworms (NWs-ICG) as the tracer. The NWs-ICG particles progressively accumulate in tumors due to the enhanced permeability and retention (EPR) effect. The proposed deep learning model exploits the advantages of the multihead attention mechanism and the U-Net model to perform segmentation on the MPI-CT images, showing superb results. In addition, the model is characterized with a different number of attention heads to explore the optimal number for our custom MPI-CT dataset. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Recurrent and convolutional neural networks for sequential multispectral optoacoustic tomography (MSOT) imaging(2023-11-01) ;Juhong, Aniwat ;Li, Bo ;Liu, Yifan ;Yao, Cheng YouYang, Chia WeiMultispectral optoacoustic tomography (MSOT) is a beneficial technique for diagnosing and analyzing biological samples since it provides meticulous details in anatomy and physiology. However, acquiring high through-plane resolution volumetric MSOT is time-consuming. Here, we propose a deep learning model based on hybrid recurrent and convolutional neural networks to generate sequential cross-sectional images for an MSOT system. This system provides three modalities (MSOT, ultrasound, and optoacoustic imaging of a specific exogenous contrast agent) in a single scan. This study used ICG-conjugated nanoworms particles (NWs-ICG) as the contrast agent. Instead of acquiring seven images with a step size of 0.1 mm, we can receive two images with a step size of 0.6 mm as input for the proposed deep learning model. The deep learning model can generate five other images with a step size of 0.1 mm between these two input images meaning we can reduce acquisition time by approximately 71%. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Cost-Effective Near Infrared Fluorescence Wide-Field Camera for Breast Tumor Imaging(2023-08-01) ;Juhong, Aniwat ;Li, Bo ;Yao, Cheng You ;Yang, Chia WeiLiu, KunliNear-infrared (NIR) fluorescence imaging has long been proven useful for numerous medical applications, especially image-guided surgery since it can deeply penetrate tissue and acquire a fluorescence image from the FDA-approved fluorescence dye known as indocyanine green (ICG). NIR imaging-guided surgery can help enhance outcomes by better defining surgical margins and minimizing operative time. However, most commercial NIR fluorescence imaging systems are bulky and expensive. In this work, we introduce a low-cost and portable NIR fluorescence imaging system. The proposed system exploits an inexpensive complementary metal-oxide-semiconductor (CMOS) based on Nyxel® technology, considerably improving quantum efficiency (QE) in the NIR range. Therefore, it can acquire a NIR fluorescence image with outstanding quality. Furthermore, we conjugated ICG with nanoworm particles (NWs-ICG) since nanoparticle-conjugated dye can increase accumulation in a tumor. We show impressive applications of our system for ex vivo tissues and in vivo image-guided surgery using NWs-ICG as a contrast agent for breast tumors from transgenic mice. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Super-resolution and segmentation deep learning for breast cancer histopathology image analysis(2023-01-01) ;Juhong, Aniwat ;Li, Bo ;Yao, Cheng You ;Yang, Chia WeiAgnew, Dalen W.Traditionally, a high-performance microscope with a large numerical aperture is required to acquire high-resolution images. However, the images’ size is typically tremendous. Therefore, they are not conveniently managed and transferred across a computer network or stored in a limited computer storage system. As a result, image compression is commonly used to reduce image size resulting in poor image resolution. Here, we demonstrate custom convolution neural networks (CNNs) for both super-resolution image enhancement from low-resolution images and characterization of both cells and nuclei from hematoxylin and eosin (H&E) stained breast cancer histopathological images by using a combination of generator and discriminator networks so-called super-resolution generative adversarial network-based on aggregated residual transformation (SRGAN-ResNeXt) to facilitate cancer diagnosis in low resource settings. The results provide high enhancement in image quality where the peak signal-to-noise ratio and structural similarity of our network results are over 30 dB and 0.93, respectively. The derived performance is superior to the results obtained from both the bicubic interpolation and the well-known SRGAN deep-learning methods. In addition, another custom CNN is used to perform image segmentation from the generated high-resolution breast cancer images derived with our model with an average Intersection over Union of 0.869 and an average dice similarity coefficient of 0.893 for the H&E image segmentation results. Finally, we propose the jointly trained SRGAN-ResNeXt and Inception U-net Models, which applied the weights from the individually trained SRGAN-ResNeXt and inception U-net models as the pre-trained weights for transfer learning. The jointly trained model’s results are progressively improved and promising. We anticipate these custom CNNs can help resolve the inaccessibility of advanced microscopes or whole slide imaging (WSI) systems to acquire high-resolution images from low-performance microscopes located in remote-constraint settings. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Metalens-based miniaturized optical systems(2019-05-01) ;Li, Bo ;Piyawattanametha, WiboolQiu, ZhenMetasurfaces have been studied and widely applied to optical systems. Ametasurface-based flat lens (metalens) holds promise in wave-front engineering for multiple applications. The metalens has become a breakthrough technology for miniaturized optical system development, due to its outstanding characteristics, such as ultrathinness and cost-effectiveness. Compared to conventional macro- or meso-scale optics manufacturing methods, the micro-machining process for metalenses is relatively straightforward and more suitable for mass production. Due to their remarkable abilities and superior optical performance, metalenses in refractive or diffractive mode could potentially replace traditional optics. In this review, we give a brief overview of the most recent studies on metalenses and their applications with a specific focus on miniaturized optical imaging and sensing systems. We discuss approaches for overcoming technical challenges in the bio-optics field, including a large field of view (FOV), chromatic aberration, and high-resolution imaging. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, MEMS actuators for optical microendoscopy(2019-01-24) ;Qiu, ZhenPiyawattanametha, WiboolGrowing demands for affordable, portable, and reliable optical microendoscopic imaging devices are attracting research institutes and industries to find new manufacturing methods. However, the integration of microscopic components into these subsystems is one of today's challenges in manufacturing and packaging. Together with this kind of miniaturization more and more functional parts have to be accommodated in ever smaller spaces. Therefore, solving this challenge with the use of microelectromechanical systems (MEMS) fabrication technology has opened the promising opportunities in enabling a wide variety of novel optical microendoscopy to be miniaturized. MEMS fabrication technology enables abilities to apply batch fabrication methods with high-precision and to include a wide variety of optical functionalities to the optical components. As a result, MEMS technology has enabled greater accessibility to advance optical microendoscopy technology to provide high-resolution and high-performance imaging matching with traditional table-top microscopy. In this review the latest advancements of MEMS actuators for optical microendoscopy will be discussed in detail. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 2-D MEMS scanner for handheld multispectral Dual-Axis confocal microscopes(2018-08-01) ;Jung, Il Woong ;Lopez, Daniel ;Qiu, ZhenPiyawattanametha, WiboolWe describe a 2-D microelectromechanical systems (MEMS) scanner for a handheld multispectral confocal microscope for early detection and diagnosis of cervical cancer. This paper is an expansion of work originally reported in the Proceedings of IEEE International Conference on Optical MEMS and Nanophotonics 2012. The MEMS scanner and fabrication process has been designed to improve performance for the dual-axis confocal microscopy architecture. Dual-axis confocal microscopy achieves comparable transverse and depth resolution to high numerical aperture (NA) single-axis confocal microscopy but achieves longer working distance by utilizing low-NA optics. The MEMS scanner has an inner gimbal design with torsional flexures separated from the reflectors to reduce light loss and oxide-free outer axis torsional flexures by utilizing poly vias for electrical access to the inner gimbal electrodes. The devices are large-scale batch fabricated using a double layer silicon-on-insulator (SOI) process and predice postreleasing of dies. The scanner has electrostatic optical deflection angles of 2° for the single-sided inner axis at 75 V and ±3° for the outer axis at 120 V. The device has resonance frequencies of ∼2.48 kHz and ∼348 Hz for the inner and outer axis torsional modes, respectively. Reflectance and fluorescence images with 650μm × 800μm field of view are demonstrated at 15 frames/s. The transverse (axial) resolutions are 4.78μm ( 6.2μm ), 5.77μm ( 6.2μm ), and 7.45μm ( 5.6μm ) for wavelengths of 561, 662, and 781 nm, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, MEMS-Based Medical Endomicroscopes(2015-07-01) ;Qiu, ZhenPiyawattanametha, WiboolProgress toward early diagnosis of cancer would have significant clinical benefits in reducing mortality or prolonging life in cancer patients; thus, there is an important unmet clinical need to image cellular features of cancer in vivo and in real time to correlate pathological symptoms and underlying cells responsible for such symptoms. In this paper, we describe a review of microelectromechanical systems scanners-based endoscopic optical coherence tomography, confocal, two-photon, and photoacoustic microscopy imaging. These advanced optical imaging modalities can provide subcellular (micron-scale) resolution and deep tissue penetration to reveal both cells and molecular features for early cancer diagnosis, cancer staging, and surgical guidance.
