KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 3 of 3
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Subsidence monitoring system for industrial machines based on magnetic field method
    (2010-12-01)
    Sriratana, Witsarut
    ;
    Nakmee, Kreangkrai
    ;
    Tanachaikhan, Lerdlekha
    This study presents the design of subsidence monitoring system for industrial machine alignment based on magnetic field method. The system was developed to demonstrate the level of land subsidence in the area of the industrial machine located. A computer was used to collect the data and to display the angles of subsidence over operation period. The measurement module consists of two thin-and-curve permanent magnets (10 mm x 41.5 mm x 1.5 mm) with the outer radius of 24 mm, the curve angle of 120 degree, and the maximum magnetic density of 0.23 Tesla. The gap between these two magnets was 12 mm to generate the magnetic tension force. The sensing module was Hall Generator placed perpendicularly to the magnetic fluxes which can generate the output voltage as a function of subsidence angle and magnetic density on X axis and Z (vertical) axis with the resolution of 100 mV per degree. There were two ranges of measurement according to the angle resolution: -20 to 20 degree at 1 degree of resolution per step and -6 to 6 degree at 0.05 degree of resolution per step. ©ICROS.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Analysis of capacitive variation using parallel-plates method
    (2009-12-01)
    Tanachaikhan, Lerdlekha
    ;
    Sriratana, Witsarut
    Capacitive variation of capacitive sensor was analyzed by using two parallel plates coated by 0.4 mm- thick nylon and fixed together by resin to maintain the distance of those two plates at 2.5 mm and 5 mm. In this study, stainless and copper were used for development of capacitive sensor. In this paper Ethel alcohol solution is used as a case study. Ethel alcohol solution with the concentration ranging from 95% to 5% with 10% step decrease of concentration diluted by distilled water was experimented under the controlled temperature of 23°C and the frequency was varied from 100 Hz to 2 kHz with 500 Hz interval. The capacitive variation analyzed from the equivalent circuit which was obtained from the developed sensor was then compared to the electrical circuit obtained from the Good Will R-L-C instrument model CRT to analyze for the appropriate material and the distance between two parallel plates (d) of the sensor. This proposed methodology was developed with consideration of the simple design for easy fabrication and low costs with high accuracy and reliability of the results. ©2009 IEEE.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Error analysis of temperature measurement system: A case of PT100
    (2009-01-01)
    Tanachaikhan, Lerdlekha
    ;
    Tammarugwattana, Narin
    ;
    Sriratana, Witsarut
    ;
    Seangratipen, Tawatchai
    This paper presents the study of uncertainty in measurement as well as the error compensation of the industrial temperature instrument under various conditions for precise and reliable results of the measurement. In this study, the temperature calibration system of PT100 was used as a case study. Data used in analysis were collected from 200 values of repetitive temperature measurement in the range of 25 °C to 100 °C using Data logger together with a computer to process, analyze, and collect in database system which was developed from Visual Basic. The efficiency and characteristics of the developed system were statistically analyzed from error, mean, standard deviation, and uncertainty of each measured value to improve the reliability of the instrument which is used in industrial processes.