KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/kmitl/1
Browse
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Dielectric Response Analysis Characteristic of Service-Aged XLPE Cables(2024-01-01) ;Thongkong, Patchara ;Promphanich, Wiboon ;Udomluksananon, Patt ;Jeenmuang, SiwakornThe main insulation used in plastic underground cables is cross-linked polyethylene (XLPE). The XLPE underground cable which has been utilized in service for a long time, has experienced various stresses, or so-called TEAM stresses. Consequently, the XLPE insulation will be degraded over time and lead to insulation properties degradation. This paper represents the dielectric response analysis technique for characterizing the insulation condition of the service-aged XLPE medium voltage underground cable. The dielectric response analysis was performed on the 22 kV XLPE underground cables that have been in service for more than 10 years and were directly buried. The dielectric response analysis measurement consists of a combination of polarization and depolarization current (PDC) measurement in the time-domain and frequency-domain spectroscopy (FDS) measurement. After that, test results were analyzed to evaluate the insulation condition and compare it to the new 22 kV underground cable. The analyzed dielectric response analysis test results will be reported in this paper.1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of Longtime Sheath Current on Insulation Screen of 115kV XLPE Underground Cable(2024-01-01) ;Jariyanurat, Kittipod ;Jeenmuang, Siwakorn ;Udomluksananon, Patt ;Kerdmanee, SittipongLacharochana, SakdaDue to the need to extend the life of underground cables that are universally installed and used in power plants in Thailand, The life assessment must be concerned with advanced techniques, both chemical and physical, exactly. The components that needed to be analyzed were divided into two main groups: the insulation and physical systems. One of the most requisites is pyrolysis. Pyrolysis can occur in the underground cable system with many factors, for instance, the ambient temperature, overload, loss of connector, and longtime sheath current. Thus, this paper described the effect of the longtime sheath current on the insulation screen of 115kV XLPE underground power cable. Sheath current that ran into the system for longtime effectively effected to the insulation screen by destroying the structure of chemical properties leading to the short lifetime and getting the high risk to breakdown with the continue use.2
