KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Simple and fast fabrication of microfluidic paper-based analytical device by contact stamping for multiple-point standard addition assay: Application to direct analysis of urinary creatinine(2020-04-01) ;Mathaweesansurn, Arjnarong ;Thongrod, Suthathip ;Khongkaew, Putthiporn ;Phechkrajang, Chutima MatayatsukWilairat, PrapinIn this work, a microfluidic paper-based analytical device (μPAD) for simultaneous multiple-point standard addition assay was fabricated by rubber stamping the hydrophobic barrier pattern onto a laboratory filter paper. The μPAD has a central zone from which an applied sample flows into eight surrounding narrow channels to which had been added the standard solutions. Each channel is connected to a circular area loaded with the reagent. The opposite end of this reagent zone is connected by second narrow channel to the final circular detection zone. The μPAD was applied to the measurement of creatinine in human urine. After addition of a urine sample, the orange-colored product arising from the Jaffé reaction is formed at the eight detection zones. A digital image of the μPAD is then recorded and the ratio of the red/green (R/G) intensity obtained using the ImageJ™ program is used in the quantitation of creatinine. The normal standard addition calibration line is constructed using the intensity ratio against the added creatinine concentrations (50–1000 mg L<sup>−1</sup>). Good linearity was achieved (r<sup>2</sup> ˃ 0.99). There were no significant differences between the creatinine content using an HPLC method (paired t-test at 95% confidence, t<inf>stat</inf> = 1.78, t<inf>critical</inf> = 2.26, n = 10). The use of simultaneous multiple-point standard addition calibration allows rapid determination of creatinine in urine with elimination of matrix interference. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Towards direct analysis of solid and liquid samples exploiting a 3D printed dialysis unit and sequential injection: Application for automated derivatization and determination of gamma-aminobutyric acid in foodstuff and beverages(2020-02-08) ;Kasetsoontorn, BhoonnarasaChoengchan, NathawutIn this work, a new design of a dialysis unit for direct analysis of solid and liquid samples is presented. The homemade unit was constructed using a 3D printer due to its simple and fast fabrication ability. The dialysis unit is composed of cylindrical-shaped donor and acceptor chambers. A stainless steel sieve is installed inside the donor chamber. SEM images clearly showed that the sieve prevented membrane blockage by suspension particles in the sample. Multiple dialysis units were connected to a sequential injection (SI) system for serial determination of gamma-aminobutyric acid (GABA) in solid and liquid samples. The dialysate from each dialysis unit was consecutively aspirated into the SI flow line for on-line derivatization of GABA with 2-hydroxy-1-naphthaldehyde (3.0% w/v). The derivative was detected spectrophotometrically at 425 nm. The linear calibration range extended to 1000 mg L<sup>−1</sup> GABA (r<sup>2</sup> > 0.99) with high precision (1.2 %RSD). The developed system was applied to analysis of dietary supplements, grains of germinated brown rice and milk. The samples were directly introduced into the donor chamber either as powder or liquids. The measured GABA content using the developed method was compared using high performance liquid chromatography, with good agreement using Pearson's correlation (r<sup>2</sup> = 0.9999). The method has high accuracy based on recovery studies (99.8 ± 1.5%) and high sample throughput (64 samples h<sup>−1</sup>).
