KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
13 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Modeling and comparative analysis of sustainable cotton rope confinement: Full vs. STrip wrapping for enhanced concrete strength and ductility(2025-07-01) ;Saingam, Panumas ;Gadagamma, Chaitanya Krishna ;Hussain, Qudeer ;Hlaing, Hnin HninSuwannatrai, RawirotThe rise of natural FRPs as ecological alternatives to synthetic ones has highlighted the need for studies on partial confinement using cotton ropes, which offer cost-effective, low-carbon solutions with high rupture strain. Unlike full confinement, partial confinement through cotton rope strips can efficiently strengthen deteriorated concrete sections with reduced material usage. Despite possessing several advantages, the partial confinement by cotton on concrete has not been investigated. This study addresses the gap by investigating the performance of cotton rope strips and developing analytical models to predict their structural impact. This study tested cylindrical concrete specimens of two strengths, strengthened with cotton rope in either complete wrapping (Group 1) or strip wrapping (Group 2). Each group was further divided by concrete strength and included one unstrengthened specimen, and three strengthened with one, two, or three layers of cotton rope. Experimental results revealed that cotton rope wraps effectively confined the concrete, enhancing load-bearing capacity and improving ultimate compressive strength by 9.97–152.10 % and ultimate strain by 188.00 % to 1488.89 %. The compressive stress vs. strain behavior exhibited an initial stiff elastic ascent followed by a parabolic transition. The second branch of the response, either ascending or descending, was significantly improved with an increased confinement ratio. Type-I failure was characterized by an ascending second branch in the compressive stress vs. strain curve, while Type-II failure exhibited a descending second branch. Four specimens demonstrated Type-I failure (L-2F, L-3F, H-3F, and L-3S), predominantly in full configurations and with lower unconfined compressive strength. The modulus of the second branch improved with an increased confinement ratio, transitioning from Type-II to Type-I failure near a ratio of approximately 0.50. Regression analysis provided equations of various key points along the compressive response with R² values greater than 0.90, highlighting a strong dependence on the confinement ratio. The Popovics model effectively predicted the first part of the compressive response, with predicted curves closely matching experimental results. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Enhancing compressive behavior of concrete with novel low-cost hybrid passive confinement including large rupture strain cotton ropes: Experimental findings and a design-oriented model(2024-12-01) ;Saingam, Panumas ;Hussain, Qudeer ;Ejaz, Ali ;Nawaz, AdnanJoklad, PanuwatRecent research have highlighted the potential of hybrid confinement, combining high tensile strength fiber-reinforced polymers with large rupture strain confinement. This study presents experimental findings on 64 cylindrical and square-shaped specimens tested under axial compression, introducing a novel hybrid confinement method utilizing low-cost fiberglass chopped strand mat sheets and cotton ropes (COFS confinement). The experimental and analytical results yielded several key conclusions. Firstly, circular specimens exhibited significant peak strength increases in various subgroups, with enhancements ranging from 97.5 % to 285.5 %, and ultimate strain improvements ranging from 588.6 % to 1650.0 %. Similarly, square specimens under COFS confinement also demonstrated notable enhancements in ultimate strength and strain, with increases up to 244.7 % and 1083.0 %, respectively, particularly evident with higher levels of confinement. The influence of cross-sectional shape on compressive strength, strain, and energy dissipation was noted, with COFS confinement notably improving these factors for circular sections. Additionally, the study found that as the unconfined compressive strength increased, the enhancement in compressive strength, ultimate strain, and energy dissipation decreased. Moreover, the confinement ratio positively affected axial behavior improvement, with a proportional enhancement observed. However, the efficacy of the confinement ratio was influenced by cross-section type and plain concrete strength, emphasizing the need for considering these factors in COFS-based confinement design. Lastly, an analytical design-oriented model proposed for approximating stress vs. strain curves of COFS-confined concrete showed close agreement with experimental results, providing valuable insights for future design considerations. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Corrigendum to ‘Enhancing compressive behavior of concrete with novel low-cost hybrid passive confinement including large rupture strain cotton ropes: Experimental findings and a design-oriented model’ [Case Stud. Constr. Mater. 21 (2024) e03496] (Case Studies in Construction Materials (2024) 21, (S2214509524006478), (10.1016/j.cscm.2024.e03496))(2024-12-01) ;Saingam, Panumas ;Hussain, Qudeer ;Ejaz, Ali ;Nawaz, AdnanJoyklad, PanuwatThe authors regret that the fifth author's name was incorrect in the published article. The correct name of the fifth author as “Panuwat Joyklad” The acknowledgement section should be updated by including the last line in the acknowledgement. The revised acknowledgement should read as: This research is a result of the project entitled “Development of a Novel, Low-cost and High Performance Hybrid FRP Composites for Waste Aggregate Concrete for Sustainable Cities Grant NO.RE-KRIS/ FF67/023” by King Mongkut's Institute of Technology Ladkrabang (KMITL), which has been received funding support from the NSRF. The APC was funded by King Mongkut's Institute of Technology Ladkrabang Research Fund. The authors would like to apologise for any inconvenience caused. DOI of original article: < https://doi.org/10.1016/j.cscm.2024.e03496> - Some of the metrics are blocked by yourconsent settings
Item type:Item, Large rupture strain cotton ropes hybridized with affordable fiberglass chopped strand mat sheets for enhanced compressive behavior of reinforced concrete columns(2024-11-15) ;Saingam, Panumas ;Gadagamma, Chaitanya Krishna ;Hussain, Qudeer ;Ejaz, AliHlaing, Hnin HninThe hybrid confinement system combines various fiber types within a single matrix, allowing for the adjustment of volumetric ratios to optimize confinement performance. Synthetic FRPs are more expensive and have a higher carbon footprint due to significant CO<inf>2</inf> emissions during production. In response, this study presents an innovative hybrid confinement approach using two natural materials: cotton ropes and FSMS (CFS) to improve concrete strength and ductility. Specimens, standardized at 300 mm height and 150 mm diameter with longitudinal steel bars and stirrups, were divided into two groups based on CFS configurations. The stress-strain response of CFS-confined concrete displayed distinctive behavior: an initial parabolic phase leading to peak compressive stress (ultimate strength), followed by a linearly degrading phase. Across all subgroups, CFS confinement significantly enhanced ultimate strength and corresponding compressive strains, with Subgroup 2A achieving the highest improvements of 246 % in ultimate strength and 1477 % in strain. Moreover, the ductility gain was reported as high as 20 for CFS-confined concrete. A non-proportional enhancement in the compressive behavior was observed with the increase in confinement ratio. Predictive models were developed for the idealized two-branch response of CFS-confined concrete, encompassing expressions based on nonlinear regression for ultimate strength, corresponding strain, ultimate strain, and elastic modulus. Two existing models were modified to trach each branch of the response. Integrating these two adjusted models closely replicated the experimental compressive curves. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Development of stress-strain models for glass fiber reinforced polymer composites confined sustainable concrete made with natural and recycled aggregates(2024-02-16) ;Yooprasertchai, Ekkachai ;Saingam, Panumas ;Hussain, Qudeer ;Khan, KaffayatullahEjaz, AliThis study addresses the mechanical limitations of concrete fabricated with recycled brick and concrete as partial replacement of coarse aggregates, which exhibit inferior strength and stiffness compared to those with natural aggregates. To rectify this, a cost-effective approach involving low-cost glass fiber-reinforced polymer composites (LOC-GFRP) is proposed. The key parameters considered were the plain concrete compressive strength and the quantity of LOC-GFRP layers. The compressive strength of LOC-GFRP-confined concrete increased with the number of layers, with greater improvements observed in lower-strength plain concrete. Moreover, the improvement in ultimate strain was more significant than the improvement in compressive strength. The compressive strength and ultimate strain were improved by 271% and 478%, respectively. LOC-GFRP confinement resulted in a bilinear compressive stress vs. strain response, showcasing increased ductility and strength with more LOC-GFRP layers. The study evaluated various existing analytical expressions for fiber-reinforced polymers but found them inadequate in predicting parameters accurately. As a result, nonlinear regression analysis was carried out to propose expressions for predicting compressive strength and ultimate strain of LOC-GFRP-confined concrete for different aggregate types. The calculated coefficient of determination values ≥ 0.90 confirmed the good correlation among experimental and predicted values. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Behavior of non-prismatic RC beams with conventional steel and green GFRP rebars for sustainable infrastructure(2023-12-01) ;Suparp, Suniti ;Khan, Inamullah ;Ejaz, Ali ;Khan, KaffayatullahWeesakul, UruyaThis study presents an experimental and finite element analysis of reinforced concrete beams with solid, hollow, prismatic, or non-prismatic sections. In the first part, a total of six beams were tested under four-point monotonic bending. The test matrix was designed to provide a comparison of structural behavior between prismatic solid and hollow section beams, prismatic solid and non-prismatic solid section beams, and prismatic hollow and non-prismatic hollow section beams. The intensity of shear was maximum in the case of prismatic section beams. The inclusion of a tapered section lowered the demand for shear. In the second part, Nonlinear Finite Element Modeling was performed by using ATENA. The adopted modeling strategy resulted in close agreement with experimental crack patterns at ultimate failure. However, the ultimate failure loads predicted by nonlinear modeling were generally higher than their corresponding experimental results. Whereas in the last part, the developed models were further extended to investigate the effect of the strength of concrete and ratio of longitudinal steel bars on the ultimate load-carrying capacity and cracking behavior of the reinforced concrete beams with solid, hollow, prismatic, or non-prismatic sections. The ultimate loads for each beam predicted by the model were found to be in close agreement with experimental results. Nonlinear modeling was further extended to assess the effects of concrete strength and longitudinal reinforcement ratio on failure patterns and ultimate loads. The parametric study involved beams reinforced with glass fiber-reinforced polymer (GFRP) bars against shear and flexural failure. In terms of ultimate load capacities, diagonal cracking, and flexural cracking, beams strengthened with GFRP bars demonstrated comparable performance to the beams strengthened with steel bars. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Enhancing the flexural behavior of brick masonry walls with ferrocement overlays and low-cost anchors(2023-12-01) ;Saingam, Panumas ;Hlaing, Hnin Hnin ;Suwannatrai, Rawirot ;Ejaz, AliHussain, QudeerThis study presents an innovative approach to enhance the flexural capacity of cement-clay interlocking (CCI) brick walls using ferrocement jackets with an expanded wire mesh. The investigation involved 15 CCI brick walls subjected to flexural load testing, exploring various mesh sizes and anchor configurations on single and dual sides. The results revealed that while the primary failure mode involved dry joint opening and subsequent ferrocement debonding in the strengthened walls, effective anchorage mechanisms delayed dry joint opening until debonding occurred. The reinforced walls exhibited improved peak load capacity, notably in dual-sided reinforcement cases. With plastering on both sides and supplemented with anchors, an improvement of up to 221% in flexural capacity was obtained. The study emphasizes the influence of wire mesh size on anchorage effectiveness and its correlation with debonding susceptibility. Additionally, the moment-curvature analysis demonstrated resilient, ductile responses in load-bearing characteristics, with occasional abrupt declines due to ferrocement jacket debonding. Unlike control walls, the strengthened walls exhibited strains exceeding yield thresholds, indicating enhanced structural performance. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Axial stress versus strain responses of CFRP confined concrete containing electronic waste aggregates(2023-12-01) ;Ullah, Saad ;Qureshi, Muhammad Irshad ;Saingam, Panumas ;Hussain, QudeerKhan, KaffayatullahThis research work investigates the axial stress versus strain responses of un-strengthened and carbon fiber reinforced polymer (CFRP) composites strengthened concrete specimens made with electronic waste coarse aggregates. For this purpose, 36 circular and non-circular 300 mm high concrete specimens constrained with CFRP sheets and partially replaced with E-waste coarse aggregates were prepared. The effect of cross-sectional geometry, 20% partial substitution of natural coarse aggregates with E-waste aggregates, corner effect of non-circular concrete specimens, confinement of specimens with CFRP sheets, and effect of the number of confinement sheets were also studied. In control concrete specimens, the coarse aggregates were 848 kg/m<sup>3</sup> and E-waste aggregates were 212 kg/m<sup>3</sup>. The cement was 475 kg/m<sup>3</sup> and fine aggregates were 655 kg/m<sup>3</sup>. Test results indicated that compressive strength is reduced by substituting natural coarse aggregates with E-waste aggregates. At the same time, compressive strength increased to 71%, 33%, and 25% for circular, square, and rectangular concrete specimens, respectively, by CFRP confinement. Whereas the axial strain increased to 1100%, 250%, and 133%, for circular, square, and rectangular concrete specimens, respectively, by CFRP confinement. CFRP sheets also enhanced the Poisson's ratio. Because of the greater confinement given by a double CFRP layer, it is more effective than a single layer. Furthermore, results also indicated that strength reduction in non-circular concrete specimens was greater than in circular concrete specimens for all studied cases. In the end, for theoretical calculations, strength and strain models for confined concrete suggested by different researchers were applied and compared with experimental results. In comparison to the experimental findings, theoretical data showed that most of the models were either on the higher or on the lower side, while only some model results matched well with the experimental data. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Load-Bearing Performance of Non-Prismatic RC Beams Wrapped with Carbon FRP Composites(2023-06-01) ;Suparp, Suniti ;Ejaz, Ali ;Khan, Kaffayatullah ;Hussain, QudeerJoyklad, PanuwatThis study investigated the influence of CFRP composite wrapping techniques on the load–deflection and strain relationships of non-prismatic RC beams. A total of twelve non-prismatic beams with and without openings were tested in the present study. The length of the non-prismatic section was also varied to assess the effect on the behavior and load capacity of non-prismatic beams. The strengthening of beams was performed by using carbon fiber-reinforced polymer (CFRP) composites in the form of individual strips or full wraps. The linear variable differential transducers and strain gauges were installed at the steel bars to observe the load–deflection and strain responses of non-prismatic RC beams, respectively. The cracking behavior of unstrengthened beams was accompanied by excessive flexural and shear cracks. The influence of CFRP strips and full wraps was primarily observed in solid section beams without shear cracks, resulting in enhanced performance. In contrast, hollow section strengthened beams exhibited minor shear cracks alongside the primary flexural cracks within the constant moment region. The absence of shear cracks was reflected in the load–deflection curves of strengthened beams, which demonstrated a ductile behavior. The strengthened beams demonstrated 40% to 70% higher peak loads than control beams, whereas the ultimate deflection was increased up to 524.87% compared to that of the control beams. The improvement in the peak load was more prominent as the length of the non-prismatic section increased. A better improvement in ductility was achieved for the case of CFRP strips in the case of short non-prismatic lengths, whereas the efficiency of CFRP strips was reduced as the length of the non-prismatic section increased. Moreover, the load–strain capacity of CFRP-strengthened non-prismatic RC beams was higher than the control beams. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Cyclic Behavior of Different Connections in Precast Concrete Shear Walls: Experimental and Analytical Investigations(2023-06-01) ;Yooprasertchai, Ekkachai ;Wiwatrojanagul, Pongsak ;Saingam, PanumasKhan, KaffayatullahThis study investigated the grouted sleeve splices and corrugated duct splices between shear walls and footing. In this regard, three shear walls were experimentally tested. One wall was cast monolithically with the foundation (RCWS), whereas two walls were precast. One wall was connected to the foundation using splice sleeves (PGWS), and another with corrugated duct splices (PCWS). All the walls were tested under reverse cyclic loading and a constant axial load. It was observed that the performance of specimen PGWS was controlled by rocking, and a premature connection loss was observed at one of the grouted sleeve splices. The hysteretic performance of specimen PCWS was close to that of specimen RCWS, whereas extensive pinching was observed in the hysteretic response of specimen PGWS. The peak load, ductility, secant stiffness, and energy dissipation of specimens RCWS and PCWS were in good agreement, whereas the energy dissipated by specimen PGWS was considerably lower than the corresponding values of specimens RCWS and PCWS. Nonlinear fiber-based modeling in OpenSees was performed using SFI-MVLEM elements. The predicted hysteretic response of the OpenSees model was in close agreement with the experimental response.
