KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Low-Cost Fiber Chopped Strand Mat Composites for Compressive Stress and Strain Enhancement of Concrete Made with Brick Waste Aggregates(2022-11-01) ;Joyklad, Panuwat ;Saingam, Panumas ;Ali, Nazam ;Ejaz, AliHussain, QudeerGiven the excessive demolition of structures each year, the issues related to the generated structural waste are striking. Bricks being a major constituent in the construction industry, also hold a significant proportion of the construction waste generated annually. The reuse of this brick waste in new constructions is an optimal solution considering cost-effectiveness and sustainability. However, the problems related to the substandard peak stress and ultimate strain of concrete constructed with recycled brick aggregates (CRAs) limit its use in non-structural applications. The present study intends to improve the unsatisfactory mechanical characteristics of CRAs by utilizing low-cost glass fiber chopped strand mat (FCSM) sheets. The efficacy of FCSM sheets was assessed by wrapping them around CRA specimens constructed with different concrete strengths. A remarkable increase in the peak compressive stress and the ultimate strain of the CRA specimens were observed. For low, medium, and high strength CRAs, the ultimate strain improved by up to 320%, 308%, and 294%, respectively, as compared to the respective control specimens. Several existing analytical models were utilized to predict the peak compressive stress and ultimate strain of the CRAs strengthened using FCSM sheets. None of the considered models reproduced experimental results accurately. Therefore, equations were formulated using regression predicting the peak stress and ultimate strain of the CRAs confined with FCSM sheets. The predicted values were found to correlate well with the experimental values. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Structural Behavior of LC-GFRP Confined Waste Aggregate Concrete Square Columns with Sharp and Round Corners(2022-09-01) ;Parichatprecha, Rattapoohm ;Rodsin, Kittipoom ;Chaiyasarn, Krisada ;Ali, NazamSuthasupradit, SongsakReusing construction brick waste to fabricate new concrete is an economical and sustainable solution for the ever-increasing quantity of construction waste. However, the substandard mechanical properties of the concrete made using recycled crushed brick aggregates (RBAC) have limited its use mainly to non-structural applications. Several studies have shown that the axial compressive performance of the concrete is a function of the lateral confining pressure. Therefore, this study proposes to use low-cost glass fiber-reinforced polymer (LC-GFRP) wraps to improve the substandard compressive strength and ductility of RBAC. Thirty-two rectilinear RBAC specimens were constructed in this study and tested in two groups. The specimens in Group 1 were tested without the provision of a corner radius, whereas a corner radius of 26 mm was provided in the Group 2 specimens. Specimens in both groups demonstrated improved compressive behavior. However, the premature failure of LC-GFRP wraps near the sharp corners in Group 1 specimens undermined its efficacy. On the contrary, the stress concentrations were neutralized in almost all Group 2 specimens with a 26 mm corner radius, except low-strength specimen with six layers of LC-GFRP. As a result, Group 2 specimens demonstrated a more significant improvement in peak compressive strength and ultimate strain than Group 1 specimens. An analytical investigation was carried out to assess the efficiency of existing compressive stress–strain models to predict the peak compressive stress and ultimate of LC-GFRP-confined RBAC. Existing FRP models were found unreliable in predicting the key parameters in the stress–strain curves of LC-GFRP-confined RBAC. Equations were proposed by using nonlinear regression analysis, and the predicted values of the key parameters were found in good agreement with the corresponding experimental values.
