KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Item,
    Enhancing convective heat transfer coefficient in a circular heat exchanger tube mounted with modified V-orifice (MVO): CFD analysis and correlations
    (2026-01-01)
    Boonloi, Amnart
    ;
    Jedsadaratanachai, Withada
    This study investigates the airflow dynamics and heat transfer (HT) profiles in a circular heat exchanger tube (CHET) mounted with a modified V-orifice (MVO) acting as a turbulator/vortex generator, which is a passive technique to enhance HT. A numerical modeling approach based on the finite volume method using a commercial software package was employed to provide detailed insights into the air flow profile, which is essential for the design of both the turbulator and the CHET system. The MVO is a turbulator derived from the orifice concept, an established engineering device, and has been adapted in combination with a V-shaped structure to effectively generate vortices and enhance HT. Key parameters expected to influence the flow and HT behavior were investigated. These include the ratio of the MVO thickness, b, to the CHET diameter, D (referred to as the blockage ratio, B-R), which was studied in the range of 0.05–0.30, and the ratio of the MVO spacing, P, to the CHET diameter (pitch ratio, P-R), which was considered at values of 1, 1.5, and 2. Attack angles of 30°, 45°, and 60° were examined for both + x and–x flow directions. The study covered turbulent flow conditions corresponding to Reynolds numbers in the range of 3,000–16000, representative of the operating conditions at the CHET inlet. The results indicate that MVO installation in the CHET acts as a flow obstruction, generating a pressure difference that induces vortex formation. These vortices play a key role in modifying the HT behavior, resulting in increased convective HT coefficients. The outcomes are summarized in forms of dimensionless variables. The highest observed HT enhancement reached 9.93 times that of the plain CHET, while the maximum thermal enhancement factor (TEF) was 1.92, obtained at an attack angle of 30°, P-R = 1, B-R = 0.25, in the +x fluid-flow direction at Re = 3,000.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Turbulent Airflow and Thermal Analysis in a Circular Tube Heat Exchanger Fitted With Turbulence-Inducing Vortex Generators (X-V Baffles)
    (2025-01-01)
    Boonloi, Amnart
    ;
    Jedsadaratanachai, Withada
    The research presents an investigation into airflow configuration, thermal behavior, and convective heat transfer enhancement in a circular heat exchanger tube fitted with turbulence generators. These turbulence generators, referred to in this study as X-V baffles (XVBs), were developed to generate swirling flow within the heat exchanger tube, which is directly related to the enhancement of heat transfer rates and the overall performance of the heat exchanger. Additionally, the XVBs were designed with consideration for practical application and ease of maintenance in real-world industrial settings. The study examines the variables influencing airflow topology and thermal structure, including the blockage ratio (g/D = 0.05–0.20), pitch ratio (P/D = 1–2), flow direction (FD-VD and FD-VU), and types of turbulence generators (Type S and Type T XVBs). The research was conducted within the turbulent flow regime, with Reynolds numbers ranging from 3000 to 12,000 (Re = 3000–12000). The results are presented in terms of observed flow behavior within the test tube, such as cross-flow streamlines, streamwise flow streamlines, Nusselt number distribution, and fluid temperature distribution. The findings clearly show the formation of swirling flow in the heat exchanger tube when XVBs are installed. An increase in the blockage ratio and a decrease in the pitch ratio lead to a more intense swirling flow. The intensity of this swirling flow is directly correlated with the degree of disturbance in the thermal boundary layer (TH-BL). The maximum enhancements in Nusselt number and friction factor due to XVB installation are 7.24 and 58.01 times greater, respectively, compared to a smooth tube without XVBs. The maximum thermal enhancement factor (TEF) achieved is 2.27, obtained from the case with the Type T XVB at a blockage ratio of g/D = 0.05, a pitch ratio of P/D = 1, and a flow direction in the FD-VD configuration.