KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
5 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Effect of arc-shaped twisted-baffles on augmented heat transfer in a rectangular duct(2023-02-01) ;Promvonge, Pongjet ;Phila, Arnut ;Chuwattanakul, Varesa ;Chokphoemphun, SuriyaEiamsa-Ard, SmithIn this current work, the effect of utilizing arc-shaped twisted-baffles (T-ABs) in a rectangular air channel on thermal performance factor (TPF) has been experimentally studied. In these experiments, the influence of the changes in parameters such as dimensions of pitch ratio (p/w), attached arc-shape angle (α), and Reynolds number (Re) are explored. The comparisons demonstrate that a channel mounted with arc-shaped twisted-baffles yielded considerably greater Nusselt numbers than a smooth channel, possibly attributable to multiple-impinging jets near the channel surface. Heat transfer enhancements of twisted arc-shaped baffles (T-AB) having larger attack angles were superior to those having smaller attack angles. The one with α = 90o offered greater heat transfer rates than the ones with α = 20o, 40o, 60o, and 80o by approximately 8%, 7%, 4%, and 2%, respectively. The superior heat transfer was attributed to the better contact between the working fluid and heat transfer surfaces. In addition, utilizing arc-shaped twisted-baffles with the lowest p/w of 4.0, in a channel produced stronger vortices and multiple impinging jets, which caused better fluid mixing than other p/w. The optimum condition is achieved using T-ABs at an attached arc-shape angle of α = 90o, p/w = 4.0 and Re = 4000, where the heat transfer rate (Nu), friction factor (f) and TPF are found to be, respectively, 3.31, 4.68 and 1.98 times greater than those of a plain channel. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermal performance of tubular heat exchanger with multiple twisted-tape inserts(2015-05-01) ;Chokphoemphun, Suriya ;Pimsarn, Monsak ;Thianpong, ChinarukPromvonge, PongjetThe paper presents an experimental investigation on enhanced heat transfer and pressure loss characteristics by using single, double, triple, and quadruple twisted-tape inserts in a round tube having a uniform heat-fluxed wall. The investigation has been conducted in the heat exchanger tube inserted with various twisted-tape numbers for co- and counter-twist arrangements for the turbulent air flow, Reynolds number (Re) from 5300 to 24000. The typical single twisted-tape inserts at two twist ratios, y/w = 4 and 5, are used as the base case, while the other multiple twisted-tape inserts are at y/w = 4 only. The experimental results of heat transfer and pressure drop in terms of Nusselt number (Nu) and friction factor (f), respectively, reveal that Nu increases with the increment of Re and of twisted-tape number. The values of Nu for the inserted tube are in a range of 1.15-2.12 times that for the plain tube while f is 1.9-4.1 times. The thermal enhancement factor of the inserted tube under similar pumping power is evaluated and found to be above unity except for the single and the double co-twisted tapes. The quadruple counter-twisted tape insert provides the maximum thermal performance. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat transfer augmentation in a circular tube with winglet vortex generators(2015-04-01) ;Chokphoemphun, Suriya ;Pimsarn, Monsak ;Thianpong, ChinarukPromvonge, PongjetThe article presents the influence of winglet vortex generators (WVGs) placed in the core flow area on thermal performance enhancement of a tube heat exchanger. The experiment was carried out in a uniform wall heat-fluxed tube by varying turbulent airflow for Reynolds number ranging from 5300 to 24000. In the present work, the WVGs with an attack angle of 30° were inserted into the test tube at four different winglet pitch ratios (R<inf>P</inf> = P/D) and three winglet-width or blockage ratios (R<inf>B</inf> = e/D). The experimental results at various R<inf>P</inf> and R<inf>B</inf> values were evaluated and compared with those for smooth tube and tubes with twisted tape or wire coil. The measurement reveals that the WVGs enhance considerably the heat transfer and friction loss above the plain tube, wire coil and twisted tape. The Nusselt number and friction factor increase with the increment of R<inf>B</inf> and Re but with the decreasing R<inf>P</inf>. The average Nusselt numbers for the WVGs with various R<inf>B</inf> are in the range of 2.03-2.34 times above the plain tube. The thermal performance for the WVGs is found to be much higher than that for the wire coil and twisted tape and is in a range of 1.35-1.59. Also, a numerical investigation is conducted to study the flow structure and heat transfer enhancement mechanisms in the winglet-inserted tube. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat transfer augmentation in a round tube with 60° winglet pair inserts(2014-01-01) ;Chokphoemphun, Suriya ;Tongyote, Pattarapan ;Promvonge, Pongjet ;Jedsadaratanachai, WithadaChompookham, TeerapatThe experimental study on heat transfer enhancement in a tubular heat exchanger fitted with 60o winglet pairs is carried out by varying airflow velocity in turbulent region in the test section having a constant wall heat-flux. Effects of three blockage ratios (BR=e/D= 0.1, 0.15 and 0.2) and three pitch ratios (PR=P/D= 1, 1.5 and 2) of the winglet pairs on heat transfer rates in the terms of Nusselt number (Nu) and pressure loss in the form of friction factor (f) are examined. The experimental results illustrated that the tube with winglet pair insert provides the heat transfer rate higher than the smooth tube around 1.7 to 2.6 times, depending upon operating conditions. The thermal enhancement factor for using the winglet-pair turbulator is in a range of 1.03 - 1.31. © (2014) Trans Tech Publications, Switzerland. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermal performance in circular tube with Co/counter-twisted tapes(2014-01-01) ;Chokphoemphun, Suriya ;Hinthao, Chayodom ;Eiamsa-Ard, Smith ;Promvonge, PongjetThianpong, ChinarukThiswork presents an experimental study on enhanced heat transfer and pressure loss characteristics in a tube having a uniform heat-fluxed wall by using small double and triple co- and counter-twisted tapes at two twist ratios, y/w=4 and 4.5. The investigation has been conducted for Reynolds number from 5300-20,000. The experimental results of the heat transfer and pressure drop are proposed in terms of Nusselt number and friction factor, respectively.The experimental results reveal thatthe maximum TEF for the triple counter-twisted tapesat smaller twist ratio isabout 1.26. © (2014) Trans Tech Publications, Switzerland.
