KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Item,
    Evaluation of aerothermal performance of a round tube with regularly-spaced multi-channel twisted tape elements installed
    (2024-06-01)
    Phila, Arnut
    ;
    Chuwattanakul, Varesa
    ;
    Thianpong, Chinaruk
    ;
    Bhattacharyya, Suvanjan
    ;
    Naphon, Paisarn
    This article presents a study of aerothermal performance of tubes with regularly-spaced multi-channel twisted tape elements (RS-MTT) installed. This research aimed to find the proper design RS-MTTs that induce swirl flow which potentially improves fluid mixing between the core fluid and the fluid near the tube wall, thereby accelerating the heat transfer rate. Additionally, the effects of Reynolds numbers and free-spacing ratios (s/y) on heat transfer, friction loss, and thermal performance behaviors were examined. The RS-MTTs having different free-spacing ratios (s/y) of 0.0, 0.25, 0.5, 0.75, and 1.0 were tested. Air was utilized as the testing fluid in experiments with Reynolds numbers (Re) spanning from 6000 to 20,000. The utilization of RS-MTTs with s/y = 0.0, 0.25, 0.5, 0.75, and 1.0 augmented heat transfer rates up to 1.74, 1.80, 1.85, 1.90, and 2.15 times given by the plain tube alone while the friction factors increased by 4.22, 4.61, 3.87, and 4.05 times, respectively. At the lowest Reynolds number of 6000, the thermal enhancement factors of the tube containing the RS-MTTs with s/y = 0.0, 0.25, 0.5, 0.75, and 1.0 reached the maximum values of 1.42, 1.35, 1.31, 1.27, and 1.23, respectively. Among the RS-MTTs tested, the RS-MTT with s/y = 0.0 showed the best thermal enhancement factor of 4.56%, corresponding to the heat transfer augmented of 11.52% with a friction penalty of 8.71%.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Thermal and swirl flow topologies in a twisted square duct with a multi-twisted tape installed
    (2020-01-01)
    Promthaisong, Pitak
    ;
    Chuwattanakul, Varesa
    ;
    Eiamsa-Ard, Smith
    This paper presents 3D numerical investigation of the turbulent flow and heat transfer characteristics of a twisted square duct installed with multi-twisted tapes. Air was used as the working fluid with flow rates in terms of Reynolds numbers ranging from 3000 to 20,000. The effects of (1) multi-twisted tape width ratios (w/H) of 0.2 to 1.0 and (2) the number of channels (N = 2 and 4) on heat transfer and flow mechanisms were studied at constant twist ratio of y/D = 3.5. The numerical results showed that twisted square duct combined with twisted tape caused swirl flows which effectively promoted fluid mixing and provided heat transfer over those of both a straight smooth square duct and twisted square duct. Increasing w/H led to increases in both heat transfer and the friction factor. At a given multi-twisted tape width ratio (w/H), the heat transfer and friction factor with N = 4 were higher than those with N = 2, while thermal enhancement factor showed the opposite trend. A maximum thermal enhancement factor of 1.93 was obtained at tape width ratio of w/H = 1.0, channel number of N = 2 and Re = 3000.