KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Item,
    Influences of twisted-tape with parallel rectangular-wing on thermal performance of a heat exchanger
    (2012-12-01)
    Eiamsa-Ard, P.
    ;
    Thianpong, C.
    ;
    Eiamsa-Ard, S.
    The present paper reports heat transfer enhancement and friction factor characteristics in the tubes inserted with rectangular-winged twisted-tapes (TT-RWs). The wing-depth ratio (d/W) was varied from 0.1 to 0.3 while the tape-twist ratio was kept constant at y/W = 4.0. The experiments were conducted under uniform heat flux condition for Reynolds number between 5500 and 20,200 (based on the inner diameter, D), using water as the working fluid. The tubes with typical twisted tape (TT) and twisted tape with alternate-axis (TA) as well as a plain tube were also tested for assessment. The obtained results demonstrate that the utilization of the tubes with TT-RWs leads to the increases of both Nusselt number and friction compared to those from the uses of the tubes with TT, TA and the plain tube. In addition, Nusselt number increases as a wing-depth ratio of the twisted tape increases. The improvement of Nusselt number is directly related to the superior destruction of the boundary layer which is responsible by the stronger swirl flow and turbulence intensity. According to the results, the TT-RW with d/W = 0.3 yields the highest Nusselt number which is around 100% higher than that of the plain tube, corresponding to the thermal performance factor of 1.36 at constant pumping power. © 2011 IEEE.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Heat transfer enhancement in a rectangular channel with twisted tape inserts
    (2009-01-01)
    Nuthong, W.
    ;
    Eiamsa-Ard, S.
    ;
    Nanan, K.
    ;
    Eiamsa-Ard, P.
    ;
    Thianpong, C.
    Experimental investigation of heat transfer and friction factor behaviors in a rectangular channel with multiple twisted tapes (MTTs) is carried out. In each run, five MTTs are simultaneously used as the swirl flow generators in a test section. The lower wall of the channel is subjected to uniform heat flux conditions while the upper wall is insulated. Parametric runs are made for Reynolds numbers ranging from 2700 to 9000, the tapes with twist-length to twist-width ratios (y/w) of 3, 4 and 5 while the aspect ratio of AR = W/H = 10 is fixed throughout. Experiments using smooth channel are also performed for comparison. The experimental results reveal that heat transfer in the channels with MTTs at twist ratios (y/w) of 3, 4 and 5 are respectively increased around 55%, 37% and 22% over those in the smooth channel. In addition, the empirical correlations of the Nusselt number and friction factor in the developed flow region for the channels fitted with MTTs are also derived.