KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 8 of 8
  • Some of the metrics are blocked by your 
    Item type:Item,
    Analysis of exergy and heat transfer in a tube fitted with flapped V-baffles
    (2024-07-01)
    Jayranaiwachira, Nuthvipa
    ;
    Promvonge, Pongjet
    ;
    Tongyote, Paritkavin
    ;
    Skullong, Sompol
    ;
    Nakhchi, Mahdi Erfanian
    Vortex generator is a device that shows promise in generating streamwise vortices that can be utilized for boosting the rate of heat transmission inside a cooling/heating system with a relatively smaller penalty in terms of friction loss. The primary goal of the current research is to maximize the comparative Nusselt number ratio (Nu/Nu<inf>0</inf>) to be as large as possible to lower the size of the system while keeping thermal performance as high as feasible to save more energy. Thus, in the current study, the impacts of inserting the flapped V-baffle vortex generator (FBVG) on the thermal effectiveness improvement of a round tube were experimentally investigated. At a fixed attack angle (α = 60°) and baffle blockage ratio (B<inf>R</inf> = b/D = 0.3), the geometrical behaviors of FBVGs placed periodically along two edges of a straight tape were six different flap angles (θ = 0°, 25°, 35°, 45°, 65° and 90°) and three ratios of baffle pitches (P/D = P<inf>R</inf> = 2.0, 1.5, and 1.0). The current V-baffles, which were positioned on both tape edges, were designed to reduce friction loss caused by interrupting the central core flow when placed on both tape sides. The measurement results focused on the friction loss and thermal behaviors, including exergy and entropy analyses for Reynolds number from 4750 to 29,270. In the findings, the Nusselt number and friction factor of FBVG at θ = 0° and P<inf>R</inf> = 1 are, respectively, up to 5.6 and 35.24 times larger than those of the smooth tube. The entropy generation (S˙<inf>gen</inf><sup>′</sup>) seems to decline as θ and P<inf>R</inf> increase, with the smallest S˙<inf>gen</inf><sup>′</sup> found at θ = 0° and P<inf>R</inf> = 1 for lower Re. The FBVG has the greatest exergy efficiency (η<inf>Ex</inf>) at θ = 0° and P<inf>R</inf> = 1. To find the true benefits of FBVG, its thermal performance is estimated and seen to reach a maximum at about 2.44 with Nu<inf>R</inf> = 4.65 at θ = 45° and P<inf>R</inf> = 1. The optimal scenario at θ = 25° and P<inf>R</inf> = 1 was preferred, however, since it yielded the largest Nu<inf>R</inf> = 5.42 at TEF = 2.39.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube
    (2023-02-01)
    Jayranaiwachira, Nuthvipa
    ;
    Promvonge, Pongjet
    ;
    Thianpong, Chinaruk
    ;
    Promthaisong, Pitak
    ;
    Skullong, Sompol
    The paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Thermal-hydraulic performance of solar receiver duct with inclined punched-ribs and grooves
    (2022-11-01)
    Jayranaiwachira, Nuthvipa
    ;
    Promvonge, Pongjet
    ;
    Thianpong, Chinaruk
    ;
    Skullong, Sompol
    The article presents an experimental study on turbulent airflow friction and thermal behaviors in a solar receiver heat exchanger duct mounted with combined inclined chamfered-groove and turbulators. The experimental work was conducted for Reynolds numbers from 5,300 to 24,000, based on the hydraulic duct diameter. The 45°-inclined punched-ribs and grooves were placed periodically on the absorber plate. The punched-rib parameters were four inclination angles (β = 0°, 45°, 90° and 135°) of the punched holes and three relative rib pitches (PR = 1, 1.5 and 2) whereas only a rib blockage ratio (BR = 0.5) and an angle of attack (α) of 45° were fixed. Similarly, the parameters of the grooves included only three groove-pitch ratios (PR), similar to the rib pitches and one groove blockage ratio (BR = 0.2). The experimental result has revealed that the combination of rib-groove turbulators at β = 0° (solid rib) and PR = 1 gives the maximum heat transfer rate and friction loss while the greatest thermal enhancement factor of 2.1 was found at β = 45°, PR = 1. Moreover, the friction loss and heat transfer correlations for this thermal system were determined.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Thermal performance of heat exchanger tube inserted with curved-winglet tapes
    (2018-01-25)
    Skullong, Sompol
    ;
    Promvonge, Pongjet
    ;
    Thianpong, Chinaruk
    ;
    Jayranaiwachira, Nuthvipa
    ;
    Pimsarn, Monsak
    The paper deals with the effect of curved-winglet (CW) inserts on thermal and flow behaviors in a constant heat-fluxed tube. A straight tape is used to support the 45° CWs mounted repeatedly on both tape sides to generate two pairs of longitudinal counter-rotating vortices along the test tube in order to assist the chaotic flow mixing and to disrupt the boundary layer leading to faster rate of heat transfer. The airflow and heat transfer behaviors in the tube are examined for Reynolds number (Re) in the range of 4150–25,400. The curved-winglet tape (CWT) parameters involved are the winglet attack angle of 45° three relative winglet heights (b/D = B<inf>R</inf> = 0.1, 0.2 and 0.3) and winglet pitches, (P/D = P<inf>R</inf> = 0.5, 1.0 and 2.0). The investigation reveals that the maximum thermal enhancement factor (TEF) of the CWT is about 1.62 at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0. For further improvement, the CWT at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0 is modified by punching the CW to be the perforated-curved-winglet tape (P-CWT) to reduce the pressure loss. The P-CWT characteristics include five different punched hole diameters (d = 1.0, 1.5, 2.0, 2.5 and 3.0 mm). The experimental results show that TEF of all the P-CWTs is higher than that of the CWT and the maximum TEF of 1.76 higher than the CWT around 9% is found for d = 1.5 mm. To understand the flow pattern and heat transfer mechanism, a three-dimensional CFD investigation is also performed and for validation, the good agreement between numerical and experimental results is found. For experimental data, empirical correlations for Nu, f and TEF for the CWT and P-CWT inserts are also determined.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Thermal behaviors in a round tube equipped with quadruple perforated-delta-winglet pairs
    (2017-01-01)
    Skullong, Sompol
    ;
    Promvonge, Pongjet
    ;
    Thianpong, Chinaruk
    ;
    Jayranaiwachira, Nuthvipa
    The article deals with an experimental investigation of enhancing convective heat transfer in a heated circular tube with pairs of perforated-delta-winglets placed repeatedly on a perforated-cross-tape (PW-XT). The perforated-delta-winglets are placed in inline array and a triangular-hole is punched on each winglet to reduce the friction loss. The aim at using the PW-XT insert is to produce streamwise-vortex flows in the tube to reduce the thickness of thermal boundary layer and to increase fluid mixing of the flow. The involved winglet parameters are composed of relative winglet height or blockage ratio, (B<inf>R</inf> = b/D = 0.1, 0.15, 0.2 and 0.25) and relative winglet pitch or pitch ratio, (P<inf>R</inf> = P/D = 0.5, 1.0, 1.5 and 2.0) and those are performed at a single delta-winglet inclination/attack angle, α = 30° and a winglet porosity ratio, A<inf>p</inf>/A<inf>w</inf> = 0.359 for Reynolds number from 4180 to 26,000. The present results of heat transfer and pressure loss displayed in terms of respective Nusselt number (Nu) and friction factor (f) show that Nu increases with increasing B<inf>R</inf>but with decreasing P<inf>R</inf>. Nu for the PW-XT insert is in a range of 1.96–5.06 times while f increases around 2.06–35.68 times above the plain tube alone. To estimate the real merits of the PW-XT, the thermal enhancement factor (TEF) is evaluated and found to be a maximum around 1.902 at B<inf>R</inf> = 0.15, P<inf>R</inf> = 1.0. In comparison, the PW-XT gives considerably higher TEF than the typical four delta-winglet pairs placed on the cross-tape (TW-XT) having the highest TEF around 1.72.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Heat transfer augmentation in a solar air heater channel with combined winglets and wavy grooves on absorber plate
    (2017-01-01)
    Skullong, Sompol
    ;
    Promvonge, Pongjet
    ;
    Thianpong, Chinaruk
    ;
    Jayranaiwachira, Nuthvipa
    ;
    Pimsarn, Monsak
    An investigation on heat transfer characteristics in a solar air heater channel using wavy grooves incorporated with pairs of trapezoidal-winglets (TW) placed on the absorber plate has been experimentally conducted. Air as the test fluid entered the test section having a constant heat-flux on the absorber plate while the Reynolds numbers obtained by controlling the airflow rate is in a range of 4500–22,000. The TW characteristics include three relative winglet-pitches (P<inf>R</inf>) and five relative winglet height or blockage ratios (B<inf>R</inf>) at a single attack angle of 45° whereas the wavy rectangular-groove parameters are three relative groove-pitch lengths (P<inf>R</inf>) similar to the TW case but at a fixed width and height. The investigation shows that the TW together with the groove provides the substantial increase in heat transfer over the smooth channel. The TW alone gives much higher heat transfer but the groove yields considerably lower pressure drop. The combined groove and TW devices at a given B<inf>R</inf>, perform the highest heat transfer and friction factor at smaller P<inf>R</inf> and also provides considerably higher thermal performance than the single device acting alone. At P<inf>R</inf> = 1, the compound device with B<inf>R</inf> = 0.28 offers the highest heat transfer and friction factor while the one with B<inf>R</inf> = 0.24 gives the maximum thermal performance.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Experimental and numerical heat transfer investigation in a tubular heat exchanger with delta-wing tape inserts
    (2016-11-01)
    Skullong, Sompol
    ;
    Promvonge, Pongjet
    ;
    Jayranaiwachira, Nuthvipa
    ;
    Thianpong, Chinaruk
    Effects of insertion of a straight tape with double-sided delta wing pairs (called “delta-wing tape”, DWT) used as a longitudinal vortex generator (LVG) on forced convective heat transfer and flow friction characteristics in a uniform heat-flux heat exchanger tube are investigated experimentally and numerically in the present work. The experiment is conducted for turbulent airflow with the Reynolds number (Re) from 4200 to 25,500. The delta wings are in a forward-wing arrangement with three wing inclination angles (α = 30°, 45° and 60°) and with five ratios of wing-pitch to tube-diameter (P/D = PR = 0.5, 1.0, 1.5, 2.0 and 2.5). Influences of the DWT insert on heat transfer in terms of Nusselt number (Nu) and pressure drop in the form of friction factor (f) are examined. The results indicate that the DWT provides the increases in Nu and f up to 505% and 69 times above the plain tube, respectively and the maximum thermal enhancement factor (TEF) is at 1.49. The 60° DWT with PR = 0.5 yields the highest Nu and f but the 30° one with PR = 1.0 gives the best TEF. To understand the flow structure and heat transfer mechanism, a three dimensional CFD simulation of the inserted tube is also performed. The simulated results are validated and are in good agreement with the current measurements. A simulated heat transfer and fluid flow structure is also reported.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Experimental and numerical heat transfer investigation in turbulent square-duct flow through oblique horseshoe baffles
    (2016-01-01)
    Skullong, Sompol
    ;
    Thianpong, Chinaruk
    ;
    Jayranaiwachira, Nuthvipa
    ;
    Promvonge, Pongjet
    An experimental and numerical work has been carried out to study the heat transfer enhancement in a heat exchanger square-duct fitted with 30° oblique horseshoe baffles (HB). In the current work, air is passed through the HB-inserted duct having a constant surface heat-flux. The air flow and heat transfer behaviors are presented for turbulent flow region, Reynolds number ranging from 4000 to 25,000. The pertinent parameters of the 30° HB elements include three relative baffle-pitches (P<inf>R</inf>=P/H=0.5, 1 and 2) and five relative baffle heights (B<inf>R</inf>=b/H=0.05, 0.1, 0.15, 0.2 and 0.25). Influences of those parameters on heat transfer and energy loss due to friction in terms of Nusselt number and friction factor, respectively are studied. The experimental result shows that at a given B<inf>R</inf>, the smallest pitch spacing (P<inf>R</inf>=0.5) provides the highest heat transfer and friction factor. The HB at B<inf>R</inf>=0.25 and P<inf>R</inf>=0.5 yields the highest heat transfer and friction factor but the one at B<inf>R</inf>=0.2 and P<inf>R</inf>=1 gives the maximum thermal performance. In addition, the thermal performance of using the HB is much higher than that of the wire coil insert, in comparison with other turbulators. To understand the heat transfer mechanism, a numerical inserted-duct flow simulation is also conducted and the obtained numerical results are in good agreement with measurements. Numerical flow and heat transfer behaviors such as streamlines, temperature and Nusselt number contours of the duct flow model are also reported.