KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
3 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed(2025-05-01) ;Du, Yuexiang ;Wongcharee, Khwanchit ;Chuwattanakul, Varesa ;Naphon, PaisarnMaruyama, NaokiThis article reports the effect of twisted tapes with continuous V-ribs on the thermal performance index characteristics of a heat exchanger tube. Numerical and experimental studies were conducted to investigate the influence of V-rib attack angles (β = 15°, 30°, and 45°) in forward and backward arrangements. This investigation employed 0.9 mm thick, continuous V-rib twisted tapes (CVRTs) made from aluminum sheets formed with a twist ratio of y/w = 4.0. The experimental results indicated that a continuous V-rib twisted tape (CVRT) was more effective in heat transfer improvement than a typical twisted tape (TT). This was due to swirl and longitudinal vortex flows that helped increase flow mixing and reduce boundary layer thickness. Decreased V-rib attack angles (β) led to greater heat transfer enhancement, pressure drop, and thermal performance index values due to the greater turbulent mixing of fluid. The numerical result revealed that a continuous V-rib twisted tape created strong longitudinal vortex flow, especially with higher attack angles. The Turbulent Kinetic Energy (TKE) and core fluid temperature increased with the insertion of CVRTs. Local Nusselt numbers also remained relatively high for heat exchanger tubes with CVRTs. The experimental study illustrated that a tube with a CVRT installed augmented heat transfer. In the experimentally studied cases, a backward arrangement had more heat transfer, a greater friction factor, and a better thermal performance index. Compared to a plain tube, a tube with CVRT installed, having β = 15°, 30°, and 45°, showed 76.8, 71.6, and 66.2% improved heat transfer, respectively. CVRTs with these three β-values, respectively, exhibited higher thermal performance than a TT. Among the investigated CVRTs, the backward-arranged tape with β = 15° offered the maximum thermal performance index, 1.13 at Re = 6000. The results are congruent with the simulation outcomes, hence supporting the CFD analysis. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Enhanced Heat Transfer of a Heat Exchanger Tube Installed with V-Shaped Delta-Wing Baffle Turbulators(2023-07-01) ;Samruaisin, Prachya ;Maza, Rangsan ;Thianpong, Chinaruk ;Chuwattanakul, VaresaMaruyama, NaokiThe influences of V-shaped delta-wing baffles on the thermohydraulic performance characteristics in a round tube were experimentally tested. The V-shaped delta-wing baffles having a set number of wings (N = 4, 6, and 8) were comparatively tested. The V-shaped delta-wing baffles with various pitch ratios of P/D = 2.0, 2.5, and 3.0 were thoroughly fitted inside a tube. In the present work, the baffles were responsible for both the recirculation/reverse flow behind the solid baffle and the longitudinal vortex flow behind the V-shaped wing. The V-shaped winged baffles with N = 8 produced high heat transfer rates by promoting the development of reverse and vortex flows. These currents aid in fluid mixing between the two streams. Experimental results suggested that utilizing V-shaped delta-wing baffles having N = 4, 6, and 8 led to Nusselt number enhancement of up to 97–105.6%, 105.8–127.8% and 114.8–138.9%, respectively. When N was 8, the V-shaped wings baffles created additional multi vortex flows, which resulted in some fluid mixing between the vortex and the reverse flow. It was discovered that a greater turbulent intensity is imparted to the flow that was occurring between the V-shaped delta-wing baffles, which led to an increase in the rate of heat transfer when the pitch ratio was decreased. The increase in Nusselt number was up to 118.26–151.3% more than it was in a tube with the lowest pitch ratio (P/D = 2.0). It was also found that the baffles with N = 8 wings and P/D = 3.0 offered a maximum aerothermal performance factor (APF) of 1.01. Furthermore, the V-shaped delta-wing baffles have the potential for energy savings at low Re ≤ 6000, indicated by the APF beyond unity. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermal Visualization and Performance Analysis in a Channel Installing Transverse Baffles with Square Wings(2022-11-01) ;Eiamsa-Ard, Smith ;Phila, Arnut ;Wongcharee, Khwanchit ;Chuwattanakul, VaresaPimsarn, MonsakThe experimental examination of local heat transfer, thermal intensification, friction factors, and thermal performance factors (TPF) in a rectangular channel with square-winged transverse baffles (SW-TB) are presented in this paper. The purpose of this study is to modify the typical transverse baffles (TB) into square-winged transverse baffles (SW-TB) in order to improve the thermal performance and heat transfer rate of the channel. The effects of SW-TBs with various wing attack angles and Reynolds numbers on the heat transfer performance characteristics were examined using a thermochromic liquid crystal sheet. In the experiments, the SW-TBs were attached to the bottom wall of the channel, which had an aspect ratio (W:H) of 3.75:1. The SW-TBs had a width (w) of 150 mm, a square perforated cross-sectional area (a × b) of 8 × 8 mm<sup>2</sup>, and attack angles (θ) of 0° (solid transverse-baffle), 22.5°, 45°, 67.5°, and 90°. The bottom wall of the channel was evenly heated, while the other walls were insulated. The temperature contours on the heated surface were plotted using temperatures obtained through using the thermochromic liquid crystal (TLC) image-processing method. Experimental results revealed that the SW-TBs created multiple impinging jets, apart from the recirculation. At the proper attack angles (θ = 22.5° and 45°), the SW-TBs offered greater heat transfer rates and caused lower friction losses, resulting in higher TPFs than the solid transverse baffles. In the current work, channels where the SW-TBs display a θ = 45° presented the greatest TPF, as high as 1.26. The multiple impinging jets issuing by the SW-TBs suppressed the size of the recirculation flow and allowed better contact between the fluid flow and channel wall.
