KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 7 of 7
  • Some of the metrics are blocked by your 
    Item type:Item,
    Influence of divergence tapered V-baffles on heat transfer behaviors in a rectangular channel
    (2026-05-15)
    Keaitnukul, Warin
    ;
    Pingta, Supapat
    ;
    Phila, Arnut
    ;
    Wongcharee, Khwanchit
    ;
    Maruyama, Naoki
    This study examines the effects of Divergence Tapered V-Baffle (henceforth DT-VB) regarding the heat transfer and friction loss behavior within the rectangle-shaped duct. The baffle attack angles (α) were set at 45°, 60°, 75°, and 90°. The experimental results indicated that as Reynolds numbers increased, the Nusselt numbers exhibited an upward trend, while the friction values showed a corresponding decrease. The Nusselt number improved consistently as the attack angle decreased, with baffles at a 60° attack angle producing the highest friction loss, followed by those at 45°, 75°, and 90°. Among the configurations tested, the 45° attack angle demonstrated the best thermal performance due to its relatively low friction loss and enhanced heat transfer. The highest thermal performance factor (TPF) of 2.13 was attained at a 45° attack angle and a Reynolds number of 6,000.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Characterization of Heat Transfer Enhancement and Flow Topology in a Three-Start Spirally Corrugated Tube
    (2025-12-01)
    Du, Yuexiang
    ;
    Phila, Arnut
    ;
    Promthaisong, Pitak
    ;
    Chuwattanakul, Varesa
    ;
    Eiamsa-ard, Smith
    The article provides a numerical analysis of the heat transfer characteristics and laminar periodic flow in a three-dimensional 3-start spirally corrugated tube. The working fluid is air, with a flow rate in terms of Reynolds numbers (Re) that ranges from 200 to 2,000. The investigation is conducted at six different pitch ratios (PR = 0.75, 1.0, 1.25, 1.5, 2.0, and 2.5) and five different depth ratios (DR = 0.02, 0.04, 0.06, 0.08, and 0.10). The results indicated that the spiral flow along the tube length was generated by the 3-start spirally corrugated tube. The swirl flow is divided into two components: the primary swirl flow, which is visible at the core, and the secondary swirl flow, which is visible at the near wall. These components contribute to the enhancement of fluid mixing, boundary layer disruption, and heat transfer on the tube wall. The Nusselt number (Nu) and friction factor (f) were increased as a result of the decrease in PR and the increase in Re and DR. The range of the Nu/Nu₀, f/f₀, and thermal performance factor (TPF) in a range analysis is 1.02 - 15.90, 0.97 - 5.52, and 0.73 - 2.33, respectively. At Re = 2,000, the corrugated tube with DR = 0.10 exhibited the greatest TPF of 2.33. Additionally, the results indicate that the 3-start spirally corrugated tube significantly improves heat transfer compared to the corresponding straight tube. The findings suggest that the structural characteristics of the flow path within the tube can be changed by a suitable PR and DR to optimize the overall heat transfer rate and thermal performance factor.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Evaluation of aerothermal performance of a round tube with regularly-spaced multi-channel twisted tape elements installed
    (2024-06-01)
    Phila, Arnut
    ;
    Chuwattanakul, Varesa
    ;
    Thianpong, Chinaruk
    ;
    Bhattacharyya, Suvanjan
    ;
    Naphon, Paisarn
    This article presents a study of aerothermal performance of tubes with regularly-spaced multi-channel twisted tape elements (RS-MTT) installed. This research aimed to find the proper design RS-MTTs that induce swirl flow which potentially improves fluid mixing between the core fluid and the fluid near the tube wall, thereby accelerating the heat transfer rate. Additionally, the effects of Reynolds numbers and free-spacing ratios (s/y) on heat transfer, friction loss, and thermal performance behaviors were examined. The RS-MTTs having different free-spacing ratios (s/y) of 0.0, 0.25, 0.5, 0.75, and 1.0 were tested. Air was utilized as the testing fluid in experiments with Reynolds numbers (Re) spanning from 6000 to 20,000. The utilization of RS-MTTs with s/y = 0.0, 0.25, 0.5, 0.75, and 1.0 augmented heat transfer rates up to 1.74, 1.80, 1.85, 1.90, and 2.15 times given by the plain tube alone while the friction factors increased by 4.22, 4.61, 3.87, and 4.05 times, respectively. At the lowest Reynolds number of 6000, the thermal enhancement factors of the tube containing the RS-MTTs with s/y = 0.0, 0.25, 0.5, 0.75, and 1.0 reached the maximum values of 1.42, 1.35, 1.31, 1.27, and 1.23, respectively. Among the RS-MTTs tested, the RS-MTT with s/y = 0.0 showed the best thermal enhancement factor of 4.56%, corresponding to the heat transfer augmented of 11.52% with a friction penalty of 8.71%.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Enhanced heat transfer performance in channel with delta-wing perforated V-type baffles
    (2023-10-01)
    Eiamsa-ard, Smith
    ;
    Phila, Arnut
    ;
    Thianpong, Chinaruk
    ;
    Chuwattanakul, Varesa
    ;
    Maruyama, Naoki
    The article examines the influence of delta-wing V-type baffles (DW-PVBs) on the average Nusselt number, local Nusselt number distribution, pressure losses, and thermal performance behaviors in a channel. Delta-wing perforated V-type baffles (DW-PVBs) mounted in a regular manner on the bottom of a channel produced two pairs of longitudinal counter-rotating vortices to enhance chaotic fluid mixing and destabilize the boundary layer, hence boosting the heat transfer. The geometric characteristics of the delta-wing V-type baffle (DW-PVBs) located on the bottom of the channel were examined at relative baffle blockage and pitch ratios (BR = h/H = 0.3 and p/H = 1.5), and five delta-wing attack angles, θ = 0<sup>o</sup> (solid V-shaped baffle), 22.5°, 45°, 67.5°, and 90°. The present DW-PVBs mounted on the channel were designed to mitigate pressure loss due to flow blockage. The experiment was done by permitting air to flow through a channel at Reynolds numbers (Re) ranging from 6000 to 24,000. The present results show that the friction factor using the DW-PVBs decreased considerably with increasing θ values. The experimental results revealed that small θ values yielded greater heat transfer and resistance than large θ values. The DW-PVBs with θ = 22.5° performed better than inserts with other θ values in terms of heat transfer rate. It was also observed that the DW-PVBs with θ = 45° gave the maximum thermal performance factor (TPF), while presenting a 13.64–17.26% lower friction factor than the solid V-shaped baffle. Furthermore, it was also found that the DW-PVBs with θ = 0°, 22.5°, 45°, 67.5°, and 90° gave peak TPF values of up to 1.87, 1.89, 1.91, 1.87, and 1.84 at the lowest Reynolds number, 6000.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Thermal evaluation of flow channels with perforated-baffles
    (2023-05-01)
    Eiamsa-ard, Smith
    ;
    Phila, Arnut
    ;
    Wongcharee, Khwanchit
    ;
    Pimsarn, Monsak
    ;
    Maruyama, Naoki
    The influences of perforated-baffles on the local Nusselt number (Nu) and thermo-hydraulic behaviors were comprehensively studied using thermochromic liquid crystal sheet. The perforated-baffles were designed in two forms: perforated-baffle (PB) and perforated-baffle with square wings (SW-PBs). Transverse solid baffles (TBs) were also tested for an assessment. All baffles had an identical height of 12 mm (e/H = 0.3). Experimental results showed that SW-PBs offered better Nu than PBs. It is also seen that PBs and SW-PBs caused lower pressure loss than TBs by around 20.49% and 13.98%, respectively. The reduction of friction loss was primarily due to the baffle perforation. In addition, the PBs yielded the thermal performance factors (TPF) up to 1.01 at the lowest Reynolds number of 6000.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Effect of arc-shaped twisted-baffles on augmented heat transfer in a rectangular duct
    (2023-02-01)
    Promvonge, Pongjet
    ;
    Phila, Arnut
    ;
    Chuwattanakul, Varesa
    ;
    Chokphoemphun, Suriya
    ;
    Eiamsa-Ard, Smith
    In this current work, the effect of utilizing arc-shaped twisted-baffles (T-ABs) in a rectangular air channel on thermal performance factor (TPF) has been experimentally studied. In these experiments, the influence of the changes in parameters such as dimensions of pitch ratio (p/w), attached arc-shape angle (α), and Reynolds number (Re) are explored. The comparisons demonstrate that a channel mounted with arc-shaped twisted-baffles yielded considerably greater Nusselt numbers than a smooth channel, possibly attributable to multiple-impinging jets near the channel surface. Heat transfer enhancements of twisted arc-shaped baffles (T-AB) having larger attack angles were superior to those having smaller attack angles. The one with α = 90o offered greater heat transfer rates than the ones with α = 20o, 40o, 60o, and 80o by approximately 8%, 7%, 4%, and 2%, respectively. The superior heat transfer was attributed to the better contact between the working fluid and heat transfer surfaces. In addition, utilizing arc-shaped twisted-baffles with the lowest p/w of 4.0, in a channel produced stronger vortices and multiple impinging jets, which caused better fluid mixing than other p/w. The optimum condition is achieved using T-ABs at an attached arc-shape angle of α = 90o, p/w = 4.0 and Re = 4000, where the heat transfer rate (Nu), friction factor (f) and TPF are found to be, respectively, 3.31, 4.68 and 1.98 times greater than those of a plain channel.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Influence of geometric parameters of alternate axis twisted baffles on the local heat transfer distribution and pressure drop in a rectangular channel using a transient liquid crystal technique
    (2019-01-01)
    Phila, Arnut
    ;
    Thianpong, Chinaruk
    ;
    Eiamsa-Ard, Smith
    This paper reports the effects of alternate axis twisted baffle geometric parameters on the heat transfer and flow characteristics within rectangular channels. In our experiments we used modified shapes of alternate axis twisted baffles according to relative pitch ratios (s/w) equal to 2-12 and twist ratios (y/w) equal to 1-5, under conditions where the angle of attack (a) was 90 and the relative blockage height (e/Dh) was at a constant value of 0.095. The results for the Reynolds numbers based on the duct hydraulic diameter ranged from 9000 to 24,000 at a constant Prandtl number, Pr = 0.707, using air as a working fluid. A 0.05 mm thick stainless-steel foil was used as a heater, and a thermochromic liquid crystal technique was used to obtain the local temperature distribution on the heated surfaces. Images were captured in areas with periodic, fully developed regions in the channel. The results show that rectangular channels equipped with alternate axis twisted baffles demonstrated 80%-185% greater heat transfer than rectangular channels with no baffles. Channels with alternate axis twisted baffles at higher twist ratios (y/w) and smaller relative pitch ratios (s/w) showed increased heat transfer, as well as pressure loss within the system, compared with other types of twisted baffles. The thermal enhancement factor of the rectangular channels equipped with alternate axis twisted baffles was higher than that for transverse baffles and smooth channels under similar operating conditions.