KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
18 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, APPLYING MELSOFT GEMINI SOFTWARE FOR DIGITAL TWIN CREATION IN AUTOMATION SYSTEM PROJECT PHASES(2026-08-01) ;Thepmanee, Teerawat ;Sopha, Watcharapon ;Asadi, Farzin ;Pongswatd, SawaiKummool, SartIn the era of Industry 4.0, Digital Twin (DT) technology played a critical role in advancing manufacturing systems, particularly in real-time process simulation, performance optimization, and strategic decision-making. This study presents the application of MELSOFT Gemini software to develop DT for simulated industrial automation project phases. The system is designed to enable seamless data access and integration from physical devices into the DT in accordance with ISO 23247. The development process comprises two phases. The pre-deployment phase involves creating 3D models and simulating system behavior within a virtual environment prior to actual implementation. The Synchronized Operation phase enables visualization in MELSOFT Gemini through the transmission of data from physical devices via Operational Technology (OT) systems and Autonomous Mobile Robots (AMRs), using standard protocols such as OPC UA. The developed system accurately replicates the actual production process, provides early safety alerts, supports connectivity with various device types, and allows for future scalability all while maintaining compliance with the ISO 23247 framework. These findings demonstrate the potential of MELSOFT Gemini as a core platform for implementing practical, industry-ready DT systems. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Toward Interoperable SCADA: Node-RED-Based Edge Integration of Heterogeneous PLCs and IoT Devices(2025-01-01) ;Smerpitak, Krit ;Kaewchaiwong, Sattachai ;Ukakimaparn, Prapart ;Julsereewong, AmphawanPongswatd, SawaiThis article presents a novel approach to supervisory control and data acquisition (SCADA) design that emphasizes interoperability through edge integration, using Node-RED as an open-source programming platform deployed on an industrial edge computer. The proposed architecture integrates multiple-vendor programmable logic controllers (PLCs) and an Internet of Things (IoT) gateway at the edge layer to enable seamless interoperability across local control systems. A lab-scale case study demonstrates the feasibility of this integration, featuring four remote terminal units (RTUs) communicating concurrently with a SIMATIC IPC327G edge computer via standard protocols. Specifically, a SIMATIC S7-1200 (RTU-1), MELSEC iQ-F FX5U (RTU-2), and CompactLogix 1769-L30ER (RTU-3) control an object sorting station, a parcel sorting station, a water temperature control station, respectively, while a UG65 gateway (RTU-4) enables bidirectional data transfer between the edge computer and LoRaWAN devices. The inclusion of InfluxDB alongside Node-RED supports data logging and reporting functionalities. By distributing protocol translation, data processing, and shop-floor supervisory control to the edge layer, the architecture achieves real-time, vendor-neutral data orchestration while maintaining compatibility with a higher-level SCADA master terminal unit (MTU) or cloud system. Experimental results from both functional and performance testing confirm the system’s viability as a cost-effective, vendor-agnostic solution for modern industrial automation, offering a scalable model for multi-protocol industrial environments. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Partial Discharge Characteristics of a Defective MV XLPE Cable(2024-01-01) ;Ekasittiphong, Woraphat ;Smerpitak, Krit ;Tangthanam, Worasak ;Jeenmuang, SiwakornPattanadech, NorasageThis paper presents the partial discharge (PD) test on a 22 kV underground cable having a simulated defect within the XLPE insulation. The defects were simulated using the nail, as the drill bits with a different drill diameter. The defect was created into the XLPE insulation layers of the underground cable. Besides, both end sides of the cable were electric field controlled. To simulate the defects for the experiment, the jacket in the middle of the cable was partially trimmed out, and the drill bits was driven through the insulation screen to the insulation layer. The diameter of the drill bits was controlled for each experiment. The PD experiment was conducted using high frequency current transformer (HFCT) sensor as an unconventional PD detection instrument. From analyzing the PD test results, a defect in the XLPE insulation causes vividly the PD inside the XLPE insulation. Consequently, the insulation gradually deteriorates undergoing the PD events. Moreover, the PD test results indicate that the larger diameter of the nail tip radius results in a higher PD magnitude than that generated by a smaller diameter. - Some of the metrics are blocked by yourconsent settings
Item type:Item, EXPERIMENTAL STUDY ON ENERGY CONSUMPTION OF TEMPERATURE CONTROL BY USING ON-OFF INTELLIGENT FUNCTION(2023-05-01) ;Pongswatd, Sawai ;Sopha, Watcharapon ;Asadi, Farzin ;Smerpitak, KritThepmanee, TeerawatIn order to save electrical energy for on-off temperature control, a useful concept of on-off intelligent function to execute in a programmable logic controller (PLC) is presented. An implementation of PLC-based control system based on electric heating is also described as a case study to demonstrate the performance of the proposed function. IEC 61131-3-based ladder diagrams were created by using Studio 5000 software to run in the PLC modeled CompactLogix L30ER. Compared with the traditional on-off control action, the proposed on-off intelligent function can minimize energy consumption of a heater used in the implemented temperature control by 4.57%-6.65%. - Some of the metrics are blocked by yourconsent settings
Item type:Item, PLC FUNCTION BLOCK CREATION FOR MINIMIZING DATA LINK LIMITATION ON CC-LINK-BASED CONVEYOR HANDLING SYSTEM(2022-07-01) ;Pongswatd, Sawai ;Niyomtamarat, Patipak ;Kummool, SartThepmanee, TeerawatIn order to solve a facing network capacity problem when improving an existing conveyor handling system controlled by programmable logic controllers (PLCs) on master-slave control and communication link (CC-Link) network at a wooden pallet manufacturer, this article presents a software technique for short-term solution. For new requirements to upgrade a pallet sortation to be automated by installing new robotic handling unit, a slave PLC using an interface module modeled FX2N-32CCL (or slave PLC1) cannot receive all specified data of pallet production models from an existing master PLC using intelligent module modeled QJ61BT11N in one communication cycle due to limited data links. To overcome this limitation, a PLC function block creation based on data sorting approach is proposed. Two new function blocks named FB SEND and FB RECEIVE are created based on IEC61131-3 standard for adding to the existing ladder diagrams, which execute on the master PLC central processing unit (CPU) and slave PLC1 CPU, respectively. Experimental results verify that the created function blocks can provide data transfers correctly between the specified sources and destinations. The data received at the slave PLC1 CPU are similar to the data sent from the master PLC CPU. With the proposed solution, the desired conveyor handling system can be upgraded according to user’s requirements. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Implementation of control and SCADA system: Case study of Allen Bradley PLC by using WirelessHART to temperature control and device diagnostic(2022-04-01) ;Thepmanee, Teerawat ;Pongswatd, Sawai ;Asadi, FarzinUkakimaparn, PrapartSystem integration for process automation promoted the technologies that were accessed to functions and data of field device, controller, and SCADA system. In addition, the data from filed devices can apply to solve device diagnostic and preventive maintenance. This paper describes the practical technique to configure and implement of control and SCADA system that focus on integration of field device, PLC controller, and SCADA system. The paper presents case study of Allen-Bradley (AB) PLC by using WirelessHART device to temperature control and device diagnostic through SCADA system. PLC's input/output (I/O) modules are installed that consists of Modbus module, digital I/O module, analog I/O module. In addition, Prosoft configuration builder and Studio 5000 software are new software to build add on Modbus instruction and ladder diagrams, respectively. The experiments perform in case study of temperature control by using Proportional–Integral–Derivative (PID) function in the AB PLC. Wonderware InTouch SCADA software is implemented to monitor the process mimic, trend, and alarm. Moreover, the technique can support the operators and engineers to make decision for process control and devices diagnostic. - Some of the metrics are blocked by yourconsent settings
Item type:Item, PFD analysis of LNG fuel gas supply system for improving combined-cycle power plant safety(2022-04-01) ;Thepmanee, Teerawat ;Julsereewong, AmphawanPongswatd, SawaiIn order to determine an unavailability of each safety function subsystem that influences on an overall unavailability of entire protection system for safety analysis and enhancement, a modeling is required. This article presents a safety system modeling to evaluate the detected–undetected failures and repairable behaviors of each safety function subsystem in the studied fuel gas supply system (FGSS), which is utilized in a combined-cycle power plant. The proposed modeling deals with probability of failure on demand (PFD) analysis for calculation of the unavailability of three safety function subsystems, which are gas analytical subsystem (GAS), fuel gas controller subsystem (FGC), and shutdown valve subsystem (SDV). The interested GAS includes two different groups of gas analyzers in 2-out-of-2 (2oo2) voting scheme, when using three gas analyzers in each group in 2-out-of-3 and diagnosis (2oo3D) voting scheme. The interested FGC consists of two controllers in 2oo2 voting scheme, when the structure of each controller is in 1-out-of-1 and diagnosis (1oo1D) voting scheme. The interested SDV consists of two shutdown valves, which are installed in 1-out-of-2 (1oo2) voting scheme. The reliability block diagram is utilized for representative of combination of all three safety function subsystems, and the fault tree is utilized for calculation of PFD unavailability of each safety function subsystem. As the results obtained from the proposed safety function modeling, the influence of three safety function subsystems on the total unavailability of the FGSS is described. In addition, an example of the proposed modeling application to provide two guidelines for effective engineering design and operation is also presented. The first is a guideline to implement an effective human machine interface (HMI) at an operator workstation for real-time monitoring of the studied FGSS in the presence of failures that can be automatically detected by device diagnosis. The latter is a guideline to maintain and troubleshoot the failures that can be revealed by proof test. Based on diagnostic information and proof test results, operation and maintenance savings can be achieved. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Design of PLC-based system for linearity output voltage of AC–DC converter(2022-04-01) ;Pongswatd, Sawai ;Smerpitak, Krit ;Asadi, FarzinThepmanee, TeerawatThis paper presents the PLC-Based system for controlling the SCR power module which is AC–DC converter proposes to linearity output voltage with trigger signal. The technique converted the trigger signal by arccosine function and analog module in the PLC. Converted signal from PLC system is fed to SCR power module instant the traditional signal. Proposed of this paper describes the PLC hardware configuration, compute/math and trigonometric functions with Studio 5000 software. In addition, the interfacing, parameters configuration, and monitoring are considered for testing. The technique with PLC-based, devices configuration and experimental results have been presented will be useful for electric power supply in the industry with more and more demand to apply the PLC system to develop the traditional industry to semi or automatic control in the industry. - Some of the metrics are blocked by yourconsent settings
Item type:Item, - Some of the metrics are blocked by yourconsent settings
Item type:Item,