KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
9 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Enhanced thermal effectiveness of square duct with V-type double-baffles: Numerical study(2024-09-01) ;Promvonge, Pongjet ;Sripattanapipat, Somchai ;Thianpong, Chinaruk ;Skullong, SompolPromthaisong, PitakThe article puts forward three-dimensional computational research on heat transmission augmentation within a square channel containing 45<sup>o</sup> V-type double-baffles positioned on the lower and top parts at regular intervals in the turbulence zone for Reynolds numbers (Re) that vary from 3000 to 20,000. The primary goal of this research is to increase the thermal effectiveness and relative Nusselt number (Nu/Nu<inf>0</inf>), in order to conserve energy and reduce the size of the heating or cooling system. The simulations utilize a finite volume approach in common with the SIMPLE algorithm, whereas the turbulent model used is the realizable k–ε. The baffles are designed to be separated vertically for reducing pressure loss. Both single V-baffles and double V-baffles have four relative pitches (PR = 0.4, 0.5, 0.6, and 1.0) and height/blockage ratios (BR = 0.05, 0.1, 0.15, and 0.2), with a fixed attack angle (α) of 45<sup>o</sup>. The computational findings show that both V-baffles are capable of producing the primary vortices, but only the double V-baffles have the ability to provide the impinging streams onto the wall, cooling the region behind the baffles. This suggests that the double V-baffles not only boost heat transmission but also reduce frictional loss. When compared to a single V-baffle, the double ones enhance heat transfer by an average of 1.04–9.94% while decreasing frictional loss by an average of 9.88–31.73%. The thermal effectiveness factor (TEF) of the double V-baffles ranges from 1.03 to 3.21, and its peak value of around 3.21 is for PR = 0.4, BR = 0.05, at lower Re. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles(2023-02-01) ;Jayranaiwachira, Nuthvipa ;Promvonge, Pongjet ;Thianpong, ChinarukSkullong, SompolThe current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube(2023-02-01) ;Jayranaiwachira, Nuthvipa ;Promvonge, Pongjet ;Thianpong, Chinaruk ;Promthaisong, PitakSkullong, SompolThe paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermal performance of heat exchanger tube inserted with curved-winglet tapes(2018-01-25) ;Skullong, Sompol ;Promvonge, Pongjet ;Thianpong, Chinaruk ;Jayranaiwachira, NuthvipaPimsarn, MonsakThe paper deals with the effect of curved-winglet (CW) inserts on thermal and flow behaviors in a constant heat-fluxed tube. A straight tape is used to support the 45° CWs mounted repeatedly on both tape sides to generate two pairs of longitudinal counter-rotating vortices along the test tube in order to assist the chaotic flow mixing and to disrupt the boundary layer leading to faster rate of heat transfer. The airflow and heat transfer behaviors in the tube are examined for Reynolds number (Re) in the range of 4150–25,400. The curved-winglet tape (CWT) parameters involved are the winglet attack angle of 45° three relative winglet heights (b/D = B<inf>R</inf> = 0.1, 0.2 and 0.3) and winglet pitches, (P/D = P<inf>R</inf> = 0.5, 1.0 and 2.0). The investigation reveals that the maximum thermal enhancement factor (TEF) of the CWT is about 1.62 at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0. For further improvement, the CWT at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0 is modified by punching the CW to be the perforated-curved-winglet tape (P-CWT) to reduce the pressure loss. The P-CWT characteristics include five different punched hole diameters (d = 1.0, 1.5, 2.0, 2.5 and 3.0 mm). The experimental results show that TEF of all the P-CWTs is higher than that of the CWT and the maximum TEF of 1.76 higher than the CWT around 9% is found for d = 1.5 mm. To understand the flow pattern and heat transfer mechanism, a three-dimensional CFD investigation is also performed and for validation, the good agreement between numerical and experimental results is found. For experimental data, empirical correlations for Nu, f and TEF for the CWT and P-CWT inserts are also determined. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermal behaviors in a round tube equipped with quadruple perforated-delta-winglet pairs(2017-01-01) ;Skullong, Sompol ;Promvonge, Pongjet ;Thianpong, ChinarukJayranaiwachira, NuthvipaThe article deals with an experimental investigation of enhancing convective heat transfer in a heated circular tube with pairs of perforated-delta-winglets placed repeatedly on a perforated-cross-tape (PW-XT). The perforated-delta-winglets are placed in inline array and a triangular-hole is punched on each winglet to reduce the friction loss. The aim at using the PW-XT insert is to produce streamwise-vortex flows in the tube to reduce the thickness of thermal boundary layer and to increase fluid mixing of the flow. The involved winglet parameters are composed of relative winglet height or blockage ratio, (B<inf>R</inf> = b/D = 0.1, 0.15, 0.2 and 0.25) and relative winglet pitch or pitch ratio, (P<inf>R</inf> = P/D = 0.5, 1.0, 1.5 and 2.0) and those are performed at a single delta-winglet inclination/attack angle, α = 30° and a winglet porosity ratio, A<inf>p</inf>/A<inf>w</inf> = 0.359 for Reynolds number from 4180 to 26,000. The present results of heat transfer and pressure loss displayed in terms of respective Nusselt number (Nu) and friction factor (f) show that Nu increases with increasing B<inf>R</inf>but with decreasing P<inf>R</inf>. Nu for the PW-XT insert is in a range of 1.96–5.06 times while f increases around 2.06–35.68 times above the plain tube alone. To estimate the real merits of the PW-XT, the thermal enhancement factor (TEF) is evaluated and found to be a maximum around 1.902 at B<inf>R</inf> = 0.15, P<inf>R</inf> = 1.0. In comparison, the PW-XT gives considerably higher TEF than the typical four delta-winglet pairs placed on the cross-tape (TW-XT) having the highest TEF around 1.72. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Experimental and numerical heat transfer investigation in a tubular heat exchanger with delta-wing tape inserts(2016-11-01) ;Skullong, Sompol ;Promvonge, Pongjet ;Jayranaiwachira, NuthvipaThianpong, ChinarukEffects of insertion of a straight tape with double-sided delta wing pairs (called “delta-wing tape”, DWT) used as a longitudinal vortex generator (LVG) on forced convective heat transfer and flow friction characteristics in a uniform heat-flux heat exchanger tube are investigated experimentally and numerically in the present work. The experiment is conducted for turbulent airflow with the Reynolds number (Re) from 4200 to 25,500. The delta wings are in a forward-wing arrangement with three wing inclination angles (α = 30°, 45° and 60°) and with five ratios of wing-pitch to tube-diameter (P/D = PR = 0.5, 1.0, 1.5, 2.0 and 2.5). Influences of the DWT insert on heat transfer in terms of Nusselt number (Nu) and pressure drop in the form of friction factor (f) are examined. The results indicate that the DWT provides the increases in Nu and f up to 505% and 69 times above the plain tube, respectively and the maximum thermal enhancement factor (TEF) is at 1.49. The 60° DWT with PR = 0.5 yields the highest Nu and f but the 30° one with PR = 1.0 gives the best TEF. To understand the flow structure and heat transfer mechanism, a three dimensional CFD simulation of the inserted tube is also performed. The simulated results are validated and are in good agreement with the current measurements. A simulated heat transfer and fluid flow structure is also reported. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat transfer and turbulent flow friction in a round tube with staggered-winglet perforated-tapes(2016-04-01) ;Skullong, Sompol ;Promvonge, Pongjet ;Thianpong, ChinarukPimsarn, MonsakThe article deals with thermal and flow resistance characteristics in a tubular heat exchanger fitted with staggered-winglet perforated tapes (WPT). The experiment was conducted in the test tube having a constant wall heat-flux for turbulent airflow, Reynolds number (Re) from 4180 to 26,000. The aim of using the WPT is to generate longitudinal vortex flows to disrupt thermal boundary layer on the tube wall and to provide stronger fluid mixing. The WPT having an winglet inclination angle of 30° was inserted into the test tube at five different winglet blockage ratios (B <inf>R</inf> = 0.1, 0.15, 0.2, 0.25 and 0.3) and three winglet pitch ratios (P <inf>R</inf> = 0.5, 1.0 and 1.5). To find an optimum thermal performance condition, the effect of B <inf>R</inf> and P <inf>R</inf> on the heat transfer and pressure loss due to flow friction in the tube is examined. The experimental results reveal that Nusselt number (Nu) and friction factor (f) for the WPT increase with the increment of B <inf>R</inf> but the reduction of P <inf>R</inf> . The highest thermal enhancement factor (TEF) of 1.71 is achieved by utilizing the WPT with B <inf>R</inf> = 0.15, P <inf>R</inf> = 1.0 at Re = 4180. Compared to staggered-winglet typical non-perforated tape (WTT), the WPT yields the TEF of about 1.2 times higher than the WTT. Correlations of Nu, f and TEF for the WPT and the WTT are also proposed. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Enhanced heat transfer in a heat exchanger square-duct with discrete V-finned tape inserts(2015-03-01) ;Noothong, Watcharin ;Suwannapan, Supattarachai ;Thianpong, ChinarukPromvonge, PongjetThe article presents an experimental and numerical study on thermal performance enhancement in a constant heat-fluxed square-duct inserted diagonally with 45° discrete V-finned tapes (DFT). The experiments were carried out by varying the airflow rate through the tested square duct with DFT inserts for Reynolds number from 4000 to 25000. The effect of the DFT with V-tip pointing upstream at various relative fin heights and pitches on heat transfer and pressure drop characteristics was experimentally investigated. Both the heat transfer and pressure drop were presented in terms of Nusselt number and friction factor respectively. Several V-finned tape characteristics were introduced such as fin- to duct-height ratio or blockage ratio (R<inf>B</inf> = e/H = 0.075, 0.1, 0.15 and 0.2), fin pitch to duct height ratio (R<inf>P</inf> = P/H = 0.5, 1.0, 1.5 and 2.0) and fin attack angle, α = 45°. The experimental results reveal that the heat transfer and friction factor values with DFT inserts increase with the increment of R<inf>B</inf> but the decrease of R<inf>P</inf>. The inserted square-duct at R<inf>B</inf> = 0.2 and R<inf>P</inf> = 0.5 provides the highest heat transfer and friction factor while the one with R<inf>B</inf> = 0.1 and R<inf>P</inf> = 1.5 yields the highest thermal performance. Also, a numerical simulation was conducted to investigate the flow structure and heat transfer mechanism inside the tested duct with DFT inserts. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Experimental study on heat transfer in square duct with combined twisted-tape and winglet vortex generators(2014-12-01) ;Promvonge, Pongjet ;Suwannapan, Supattarachai ;Pimsarn, MonsakThianpong, ChinarukThe article presents an experimental investigation on thermal performance enhancement in a constant heat-fluxed square duct fitted with combined twisted-tape and winglet vortex generators. The experiments are carried out for the airflow rate through the tested square duct fitted with both the vortex generators for Reynolds number from 4000 to 30,000. The effect of the combined twisted tape and rectangular winglet inserts on heat transfer and pressure drop presented in terms of respective Nusselt number and friction factor is experimentally investigated. The characteristics of the combined twisted-tape and winglet include two twist ratios (Y=4 and 5), three winglet- to duct-height ratios, (R<inf>B</inf>=0.1, 0.15 and 0.2), four winglet-pitch to tape-width ratios, (R<inf>P</inf>=2, 2.5, 4 and 5) and a single attack angle of winglet, α=30°. The experimental results reveal that the Nusselt number and friction factor for the combined twisted-tape and V-winglet increase with increasing R<inf>B</inf> but decreasing R<inf>P</inf>. The inserted duct at R<inf>B</inf>=0.2, R<inf>P</inf>=2 and Y=4 provides the highest heat transfer rate and friction factor but the one at R<inf>B</inf>=0.1, R<inf>P</inf>=2 and Y=4 yields the highest thermal performance. The application of combined vortex-flow devices gives thermal performance around 17% higher than the twisted tape alone.