KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 3 of 3
  • Some of the metrics are blocked by your 
    Item type:Item,
    Partial Discharge Localization Model in Power Transformer with Fingerprinting Technique
    (2023-01-01)
    Chaisang, Aditep
    ;
    Tiengthong, Thanadol
    ;
    Maw, Myo Myint
    ;
    Promwong, Sathaporn
    Partial discharge localization in power transformers is of utmost importance, requiring an effective evaluation method to identify the location of such events precisely. Antenna placement poses challenges within power transformers, as improper positioning can significantly affect localization precision. This paper introduces an evaluation of the fingerprinting method for ultra-high frequency partial discharge localization. The fingerprinting method, commonly employed in wireless localization systems, is utilized to assess the accuracy of partial discharge localization. The proposed method leverages fingerprinting analysis and received signal strength to evaluate partial discharge events in power transformers. Experimental partial discharge measurements are conducted on a power transformer model provided by Tesla Power Company. The results include the average received signal strength at each measurement position and the distance error of the partial discharge location determined using the fingerprinting method. This research contributes to assessing partial discharge in power transformers, offering valuable insights for enhancing their health and performance evaluation.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Evaluation of UHF transfer function in a power transformer for real-time partial discharge detection
    (2020-08-14)
    Promwong, Sathaporn
    ;
    Tiengthong, Thanadol
    The UHF transfer function is significant for a short-range communication system, e.g., a real-time diagnosis of partial discharge (PD). Real-time diagnosis of the PD has become a challenging topic of improving the diagnosis of high voltage equipment, including a power transformer. Further, the PD detection in high voltage equipment is critical since the PD can cause severe damage to electrical systems. The PD detection methods are classified by a phenomenon of the PD. The PD detection by electromagnetic (EM) method is regulated by IEC TS 62478, which specified the UHF band for the PD detection in power transformers. Hence, an evaluation of frequency characteristics is essential to achieve an excellent diagnostic performance. In this paper, a complex form of channel analysis is applied with the PD detection method. The measurement model in a power transformer is proposed. The optimum receiver is introduced to maximize SNR and hence it is easy to analyze the results. The results were analyzed by using magnitude, phase, group delay, received waveform, and path loss parameters. The results show that the measured channel is affected by the structure of the power transformer. The contribution of this research is useful for improving the precision of the PD detection with EM method and building an accurate real-time partial diagnosis via a smartphone or laptop computer.
  • Some of the metrics are blocked by your 
    Item type:Item,
    Evaluation of partial discharge localization in power transformer with weighted centroid method
    (2019-07-01)
    Tiengthong, Thanadol
    ;
    Sanguanpuak, Chanidaphar
    ;
    Southisombat, Khamphoui
    ;
    Promwong, Sathaporn
    Partial discharge localization in power transformer is very important. A suitable evaluation method is one of the most critical part in order to find the exactly location of partial discharge. In this paper, an ultra-high frequency partial discharge localization is introduced. Weighted centroid method is one of a suitable method to evaluate the localization in partial discharge localization as well as other wireless localization system. There are many limitation of place to install the antenna in power transformer. The proper antenna placing is very important issue because improper location will affect the accuracy of partial discharge localization. The experiment of partial discharge measurement is carried out on a power transformer model from tesla power company. The purposed method used weighted centroid with received signal strength to evaluation the partial discharge in power transformer. The results show average value of received signal strength at each measurement position and the distance error of partial discharge location with weighted centroid method. The benefits of this method is useful to evaluate the partial discharge in power transformer.