KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
4 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Effect of antimony trioxide and carbon black on the mechanical properties and ablation properties of liner insulation in rocket motors(2021-01-01) ;Kitinirunkul, Thirapat ;Kitchaiya, Prakob ;Kiriratnikom, Chesda ;Boonyarat, PaisarnNuanklai, SuchuchchaiThis study focused on the mechanical properties and ablation properties of liner insulation in rocket motors for improving rocket performance by means of tensile strength, elongation, ablation rate and density. The following parameters were varied: amount of zinc oxide, antimony trioxide and carbon black (N550). It was found that the insulation of the rocket motors with antimony trioxide and carbon black provided higher the elongation and ablation rate. Thus, it was able to endure more heat from hot gas in combustion chamber. The result suggests that use of antimony trioxide and carbon black as filler in liner insulation can improve the thermal insulators and case-bonded in rocket motor between the solid propellant and the rocket motor tube. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Finite-element analysis of hepatic multiple probe radio-frequency ablation(2002-07-30) ;Haemmerich, Dieter ;Tungjitkusolmun, Supan ;Staelin, S. Tyler ;Lee, Fred T.Mahvi, David M.Radio-frequency (RF) ablation is an important means of treatment of nonresectable primary and metastatic liver tumors. RF ablation, unlike cryoablation (a method of tumor destruction that utilizes cold rather than heat), must be performed with a single probe placed serially. The ablation of any but the smallest tumor requires the use of multiple overlapping treatment zones. We evaluated the performance of a configuration incorporating two hooked probes (RITA model 30). The probes were lined up along the same axis in parallel 20 mm apart. Three different modes applied voltage to the probes. The first mode applied energy in monopolar mode (current flows from both probes to a dispersive electrode). The second mode applied the energy to the probes in bipolar mode (current flows from one probe to the other). The third method applied the energy sequentially in monopolar mode (in 2-s intervals switched between the probes). We used the finite-element method (FEM) and analyzed the electric potential profile and the temperature distribution at the end of simulation of a 12-min ablation. The alternating monopolar mode allowed precise independent control of the amount of energy deposited at each probe. The bipolar mode created the highest temperature in the area between the probes in the configuration we examined. The monopolar mode showed the worst performance since the two probes in close vicinity create a disadvantageous electric field configuration. We, thus, conclude that alternating monopolar RF ablation is superior to the other two methods. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation(2002-02-26) ;Cao, Hong ;Tungjitkusolmun, Supan ;Choy, Young Bin ;Tsai, Jang ZernVorperian, Vicken R.During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Flow effect on lesion formation in RF cardiac catheter ablation(2001-04-23) ;Cao, Hong ;Vorperian, Vicken R. ;Tungjitkusolmun, Supan ;Tsai, Jang ZernHaemmerich, DieterThis study investigated the flow effect on the lesion formation during radio-frequency cardiac catheter ablation in temperature-controlled mode. The blood flow in heart chambers carries heat away from the endocardium by convection. This cooling effect requires more power from the ablation generator and causes a larger lesion. We set up a flow system to simulate the flow inside the heart chamber. We performed in vitro ablation on bovine myocardium with three different flow rates (0 L/min, 1 L/rain and 3 L/min) and two target temperatures (60 °C and 80 °C). During ablation, we also recorded the temperatures inside the myocardium with a three-thermocouple temperature probe. The results show that lesion dimensions (maximum depth, maximum width and lesion volume) are larger in high flow rates (p < 0.01). Also, the temperature recordings show that the tissue temperature rises faster and reaches a higher temperature under higher flow rate.
