    The Effect of Insulating Oil Conditions in Transformer Bushing on Dielectric Response Analysis
    (2024-01-01)
    Srisub, Chanatip
    ;
    Maneerat, Noppadol
    ;
    Rojanasunan, Warisanan
    ;
    Buranaaudsawakul, Techatat
    ;
    Pannil, Pittaya
    The bushing is one of the important parts of a transformer. Once the transformer is operated; each transformer part including its bushing starts the degradation mechanism. In some cases, the dielectric strength degradation of the bushing can lead to severe consequences. Thus, the study and diagnosis of the bushing conditions are important. This study aims to investigate the characteristics of the oil-impregnated pressboard bushing under various oil conditions by filling the new mineral oil with a controlled moisture content and letting it reach an equilibrium state to examine the dielectric response of such bushing. To determine the dielectric characteristics of the investigated bushing, A Frequency Domain Spectroscopy (FDS) device was utilized. In the experiment, the dissipation factor, capacitance, and current measurement of the bushing with different water content level were measured. The bushing test object was tested with the frequency range of 1 mHz -1 kHz. The effect of moisture clearly influenced the low-frequency ranges of the FDS. The result will be discussed in the paper.
  • Some of the metrics are blocked by your 
    Item type:Item,
    The Dielectric Properties in Frequency Domain of the 22 kV Underground Cables with Defective Joint
    (2023-01-01)
    Udomluksananon, Patt
    ;
    Jeenmuang, Siwakorn
    ;
    Chumpiboon, Komin
    ;
    Dorkmai, Kritsada
    ;
    Rojanasunan, Warisanan
    The failure that occurs in the underground cable systems leads to losses in many aspects, not only in the power system but also in the commercial and business. The most failure location in medium voltage underground cable systems is cable joint and cable termination, where the defects occur from poor workmanship. This paper represents the mean to investigate the dielectric properties of the 22 kV XLPE underground cable system to assess the insulation's integrity of the underground cable system. In the experiments, the underground cable system specimens were prepared by simulating the defects in cable joints, i.e., the iron powder on the XLPE surface and the incision on the XLPE surface; moreover, the underground cable system with the healthy condition joint was prepared to represent the new (or unused) underground cable system. To compare the dielectric properties in the frequency domain of the 22 kV underground cable systems with defective joints and the healthy condition joint, the frequency domain spectroscopy (FDS), the off-line non-destructive test, was performed in this research. From the test results, the dielectric dissipation factor shows a significantly different value in the case of iron powder when compared with the healthy condition joint. It reveals the loss peak on the curve at a frequency of 1 Hz. However, the case of incision on the XLPE surface is almost similar to the healthy condition case. The real part of the complex capacitance of all three cases has a constant value in the measured frequency ranges using the log-log scale. However, the imaginary part capacitance shows the distinct value of all three cases, of which the trends are the same as the dielectric dissipation factor curve.