Item type:Item, Numerical Solutions of Transonic to Supersonic Flow over Backward-Forward Facing Step with Heat Flux Conditions(2026-03-06) ;Jeatrakul, Karn ;Prapamonthon, Prasert ;Tanpradit, Ditthaphat ;Wongsatanawarid, AtikornHao, ZhanzhouFlows phenomena over a backward-facing step (BFS) and a forward-facing step (FFS) are critical for understanding flow physics in engine, aerodynamic, heat transfer systems. Given the rapid advancement of high-speed technology, the presence of shock waves and aerodynamic heat can have an impact on flow physics, thereby emphasizing the importance of high-speed flow over BFS and FFS with heat transfer. This paper presents numerical solutions of steady two-dimensional viscous turbulent flow over a continuous backward-forward facing step (BFFS) in the transonic to supersonic regime with heat flux conditions using STAR-CCM+. The compressible air and k-ϵ turbulence model are used for the simulations. The effects of inlet Mach numbers ranging from 0.8 to 3.0 and bottom step heat fluxes varying from 0.5 to 10.0 kW/m<sup>2</sup> on flow physics are investigated. Numerical results depict flow phenomena such as flow separation, recirculation, and shock wave, as well as thermal distribution. Furthermore, the results show that variations in the inlet Mach number affect flow behaviors, while higher heat fluxes cause dramatical changes in Nusselt number, especially, in the BFS corner for transonic flow. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube(2026-03-01) ;Lin, Jianyu ;Laphirattanakul, Ponepen ;Bhattacharyya, Suvanjan ;Thapmanee, PiphatpongWongcharee, KhwanchitThis study experimentally investigates the thermal–hydraulic performance of heat exchanger tubes fitted with wired twisted tapes, with particular emphasis on the effects of the hole spacing-to-width ratio (s/W) and edge margin-to-width ratio (e/W). Experiments were conducted over a Reynolds number range of 6000–20,000, and the results were compared with those of plain tubes and tubes equipped with conventional twisted tapes. The findings revealed that the incorporation of wires significantly enhanced heat transfer due to the combined action of longitudinal eddies generated by wire protrusions and swirling flow induced by the twisted tape. At identical Reynolds numbers, tubes with a smaller hole spacing (s/W = 0.16) exhibited superior heat transfer performance, achieving Nusselt number enhancements of up to 107.7% relative to plain tubes and 51.6% relative to conventional twisted tapes. Similarly, reducing the edge margin ratio intensified near-wall eddies and further disrupted the boundary layer. The friction factor was found to increase with decreasing hole spacing and edge margin, primarily due to additional flow obstructions and enhanced near-wall shear stresses. For wired twisted tapes with s/W = 0.16, the friction factor reached nearly six times that of a plain tube. Despite this penalty, the thermal performance factor (TPF) remained favorable, with values of up to 1.2, indicating that the heat transfer benefits outweighed the corresponding pressure losses. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat Transfer Analysis in a Channel Mounted with In-Line Downward-Facing and Staggered Downward-Facing Notched Baffles(2025-09-01) ;Phila, A. ;Keaitnukul, W. ;Kumar, M. ;Pimsarn, M.Chokphoemphun, S.This study presents a comprehensive analysis of heat transfer enhancement, flow resistance, and thermal performance in rectangular channels equipped with three baffle configurations: conventional transverse baffles (TBs), in-line downward-facing notched baffles (IDF-NBs), and staggered downward-facing notched baffles (SDF-NBs). The influence of the pitch-to-baffle height ratio (P/e), ranging from 2.0 to 10, was examined across Reynolds numbers from 6000 to 24,000. Results indicate that a P/e ratio of 6.0 consistently yielded the highest Nusselt numbers across all configurations. While the TB configuration produced significant heat transfer at P/e= 6.0, it experienced a substantial friction penalty, with its best thermal enhancement factor (TEF = 1.168) observed at P/e = 8.0. The IDF-NB configuration achieved optimal performance at P/e = 6.0 with a TEF of 1.257, offering a better balance between heat transfer and flow resistance. The SDF-NB arrangement outperformed all other cases, delivering the highest Nusselt number (Nu = 116.9), TEF (1.362), and improved flow reattachment, primarily due to enhanced mixing from the staggered layout. These findings demonstrate that the staggered notched baffle configuration at P/e = 6.0 offers the most effective thermal performance enhancement among the configurations studied. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed(2025-05-01) ;Du, Yuexiang ;Wongcharee, Khwanchit ;Chuwattanakul, Varesa ;Naphon, PaisarnMaruyama, NaokiThis article reports the effect of twisted tapes with continuous V-ribs on the thermal performance index characteristics of a heat exchanger tube. Numerical and experimental studies were conducted to investigate the influence of V-rib attack angles (β = 15°, 30°, and 45°) in forward and backward arrangements. This investigation employed 0.9 mm thick, continuous V-rib twisted tapes (CVRTs) made from aluminum sheets formed with a twist ratio of y/w = 4.0. The experimental results indicated that a continuous V-rib twisted tape (CVRT) was more effective in heat transfer improvement than a typical twisted tape (TT). This was due to swirl and longitudinal vortex flows that helped increase flow mixing and reduce boundary layer thickness. Decreased V-rib attack angles (β) led to greater heat transfer enhancement, pressure drop, and thermal performance index values due to the greater turbulent mixing of fluid. The numerical result revealed that a continuous V-rib twisted tape created strong longitudinal vortex flow, especially with higher attack angles. The Turbulent Kinetic Energy (TKE) and core fluid temperature increased with the insertion of CVRTs. Local Nusselt numbers also remained relatively high for heat exchanger tubes with CVRTs. The experimental study illustrated that a tube with a CVRT installed augmented heat transfer. In the experimentally studied cases, a backward arrangement had more heat transfer, a greater friction factor, and a better thermal performance index. Compared to a plain tube, a tube with CVRT installed, having β = 15°, 30°, and 45°, showed 76.8, 71.6, and 66.2% improved heat transfer, respectively. CVRTs with these three β-values, respectively, exhibited higher thermal performance than a TT. Among the investigated CVRTs, the backward-arranged tape with β = 15° offered the maximum thermal performance index, 1.13 at Re = 6000. The results are congruent with the simulation outcomes, hence supporting the CFD analysis. - Some of the metrics are blocked by yourconsent settings
Item type:Item, NUMERICAL INVESTIGATION ON DAMAGE SCENARIOS OF VANE TRAILING EDGE USING THERMO-FLUID-STRUCTURAL ANALYSIS(2025-01-01) ;Jeatrakul, Karn ;Tanpradit, Ditthaphat ;Prapamonthon, Prasert ;Raja, VijayanandhKe, ZhaoqingGas-turbine nozzle vanes are used to increase the velocity magnitude of hot gas exiting the combustor. Thus, the vanes must operate at high turbine inlet temperatures (TITs). Essentially, the higher the turbine inlet temperature, the greater the thermal efficiency and propulsive efficiency. Nonetheless, this situation can cause severe damage to the vane material because of the repeated high thermal loads. Using thermo-mechanical analysis, this paper presents damage scenarios of a nozzle vane's trailing edge (TE) and their impact on flow and heat phenomena, including mechanical behavior of the vane material. As the upstream process, computational fluid dynamics (CFD) simulation with conjugate heat transfer (CHT) is used to numerically investigate flow physics and heat transfer phenomena. Then, for the downstream calculations, a static structure model for a steady temperature analysis is used. The NASA-MARK II vane profile is used to define vane boundaries in the computational domain. Broken vane TE scenarios are presented in both the streamwise and spanwise directions, with a short, shallow cutback expanding into a long, deep one from 0.1 cm x 1 cm to 0.3 cm x 3 cm. The numerical results are mainly presented and discussed in terms of variations in surface and internal temperatures, as well as von Mises equivalent stress and strain. The damaged TE, according to the findings, has a significant impact on the thermo-mechanical variations of the vane material. This emphasizes the severity of a damaged vane TE if the turbine is still operating without maintenance. - Some of the metrics are blocked by yourconsent settings
Item type:Item, NUMERICAL ANALYSIS OF FILM COOLING FLOW OVER FLAT PLATE WITH CONVECTIVE HEAT TRANSFER CONDITIONS(2025-01-01) ;Jeatrakul, Karn ;Koysomboon, Annop ;Prapamonthon, PrasertRattanakijsuntorn, KomsanFilm cooling is a systematically designed and widely used technique in cutting-edge gas turbine engines to reduce the surface temperature of gas turbine blades and endwalls, thereby lowering material temperature. Cooling air is emitted from the film holes to protect the external surface, which is exposed to high temperatures from the mainstream gas. As a result, the flow physics of cooling air mixing with the mainstream is critical, and it remains difficult for gas turbine designers to improve cooling efficacy due to the complexity of heat convection phenomena. This paper presents a numerical study onto problems of convective heat transfer in film cooling flow over a flat plate model using 3D computational fluid dynamics (CFD) available in STAR CCM+. The SST k- turbulence model and the realizable k- turbulence model with two-layer all y+ wall treatment are taken into consideration. To solve the problems, the flat plate surface is subjected to adiabatic (Cases 1-2) and constant heat flux conditions of 500 and 1000 W/m<sup>2</sup> (Cases 3-6, respectively). The study is conducted at the density ratio (DR) of 1.2 and blowing ratios (BRs) of 0.3 and 0.6. Numerical solutions for both conditions are presented in terms of adiabatic film effectiveness (ηad), dimensionless temperature (θ), and Nusselt number (Nu). Based on a comparative analysis of adiabatic and heat flux conditions, the results show that both the centerline and laterally adiabatic film effectiveness at the two BRs decrease streamwise. At the same BR, the dimensionless temperature values are lower at 1000 W/m<sup>2</sup> than at 500 W/m<sup>2</sup>. This includes less film coverage in the downstream. At BR = 0.6, increasing heat flux from 500 W/m<sup>2</sup> to 1000 W/m<sup>2</sup> significantly reduces film coverage size in both streamwise and spanwise directions. - Some of the metrics are blocked by yourconsent settings
Item type:Item, A Feasibility Study for the Hot-Air-Assisted Reflow Soldering Process Based on Computational Fluid Dynamics(2024-10-01) ;Kanjad, Natcha ;Chanbandit, ChanapatThongsri, JatupornIn hard disk drive (HDD) manufacturing, a reflow soldering process (RSP) employs heat generated at the welding tip (WT) to bond tiny electrical components for assembling an HDD. Generally, the heat was generated by an electric current applied to the WT. This article reports a feasibility study of using hot air based on computational fluid dynamics (CFD), a choice to assist heat generation. First, the WT and hot air tube (HAT) prototypes were designed and created. The HAT is a device that helps to supply hot air directly to generate heat at the WT. Then, the experiment was established to measure the temperature (T) supplied by the hot air. The measure results were employed to validate the CFD results. Next, the prototype HAT was used to investigate the T generated at the WT by CFD. The comparison revealed that the T measured by the experiment was in the 106.2 °C–133.5 °C range and that the CFD was in the 107.3 °C–136.6 °C range. The maximum error of the CFD results is 2.3% compared to the experimental results, confirming the credibility of the CFD results and methodology. The CFD results revealed that the operating conditions, such as WT, HAT designs, hot air inlet velocity, and inlet temperature, influence the T. Last, examples of suitable operating conditions for using hot air were presented, which confirmed that hot air is a proper choice for a low-temperature RPS. - Some of the metrics are blocked by yourconsent settings
Item type:Item, The Development of a High-Efficiency Small Induction Furnace for a Glass Souvenir Production Process Using Multiphysics(2024-09-01) ;Thongsri, Jatuporn ;Poopanya, Piyawong ;Sriphalang, SanguansakPattanapichai, SorathornA small induction furnace (SIF), which has the important components of copper coils, a ceramic jig, and a graphite crucible, employed for a glass souvenir production process, has been developed as a form of clean technology for multiphysics, consisting of electromagnetics analysis (EA) and thermal analysis (TA). First, two experiments were established to measure parameters for multiphysics results validation and boundary condition settings. Then, the parameters were applied to multiphysics, in which the EA revealed magnetic flux density (B) and ohmic losses, and the TA reported a temperature consistent with the experimental results, confirming the multiphysics credibility. Next, a ferrite flux concentrator was added to the SIF during development. Multiphysics revealed that PC40 ferrite, as a flux concentrator with a suitable design, could increase B by about 159% compared to the conventional SIF at the power of 1000 W. As expected, the B increases alongside the increase in power applied to the coils, and is more densely concentrated in the flux concentrator than in other regions, enhancing the production process efficacy. Lastly, the developed SIF was employed in the actual process and received good feedback from users. The novel research findings are the developed SIF and methodology, exclusively designed for this research and practically employed for a glass souvenir production process. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Multiphysics to Investigate the Thermal and Mechanical Responses in Hard Disk Drive Components Due to the Reflow Soldering Process(2024-09-01) ;Kimaporn, Napatsorn ;Samakkarn, ChawitThongsri, JatupornIn hard disk drive (HDD) manufacturing, a reflow soldering process (RSP) implements heat generated by the welding tip to melt a solder ball for bonding the following essential HDD components: a flexible printed circuit (FPC) and a printed circuit cable (PCC). Since the mentioned components are tiny and comprise many thin material layers, an experiment to study thermal and mechanical responses is complex and not worth it. Therefore, a static state multiphysics consisting of thermal analysis (TA) and structural analysis (SA) was employed to investigate both responses. First, the experiment was established to mimic the RSP, measuring the temperature generated by the actual welding tip. Then, the measured temperature was defined as the boundary conditions with the pressing force (F) for the TA and SA based on the actual operating conditions. As expected, the TA results revealed the temperature distribution in the HDD components, which was consistent with the theory and results from previous work and confirmed this work’s credibility. Significantly, the SA reported severe total deformation (δ) in FPC’s top and bottom ends. The maximum δ was 0.72–0.88 mm for the F of 0–1 N. The stronger the F, the greater the δ. This research highlights that multiphysics can investigate both responses in HDD components as slight as 0.1–100 microns thick, which can be used to develop a high-efficacy RSP. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Enhanced Heat Transfer of a Heat Exchanger Tube Installed with V-Shaped Delta-Wing Baffle Turbulators(2023-07-01) ;Samruaisin, Prachya ;Maza, Rangsan ;Thianpong, Chinaruk ;Chuwattanakul, VaresaMaruyama, NaokiThe influences of V-shaped delta-wing baffles on the thermohydraulic performance characteristics in a round tube were experimentally tested. The V-shaped delta-wing baffles having a set number of wings (N = 4, 6, and 8) were comparatively tested. The V-shaped delta-wing baffles with various pitch ratios of P/D = 2.0, 2.5, and 3.0 were thoroughly fitted inside a tube. In the present work, the baffles were responsible for both the recirculation/reverse flow behind the solid baffle and the longitudinal vortex flow behind the V-shaped wing. The V-shaped winged baffles with N = 8 produced high heat transfer rates by promoting the development of reverse and vortex flows. These currents aid in fluid mixing between the two streams. Experimental results suggested that utilizing V-shaped delta-wing baffles having N = 4, 6, and 8 led to Nusselt number enhancement of up to 97–105.6%, 105.8–127.8% and 114.8–138.9%, respectively. When N was 8, the V-shaped wings baffles created additional multi vortex flows, which resulted in some fluid mixing between the vortex and the reverse flow. It was discovered that a greater turbulent intensity is imparted to the flow that was occurring between the V-shaped delta-wing baffles, which led to an increase in the rate of heat transfer when the pitch ratio was decreased. The increase in Nusselt number was up to 118.26–151.3% more than it was in a tube with the lowest pitch ratio (P/D = 2.0). It was also found that the baffles with N = 8 wings and P/D = 3.0 offered a maximum aerothermal performance factor (APF) of 1.01. Furthermore, the V-shaped delta-wing baffles have the potential for energy savings at low Re ≤ 6000, indicated by the APF beyond unity.
- «
- 1 (current)
- 2
- 3
- »