Saingam, Panumas
Loading...
57 results
Now showing 1 - 10 of 57
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Innovative Approaches to RC Deep Beam Strengthening: Evaluating Low-Cost Glass Fiber Wraps Against Traditional CFRP Solutions(2025-03-01); ;Ejaz, Ali ;Gadagamma, Chaitanya Krishna ;Hussain, QudeerSua-iam, GritsadaThis study evaluates the performance of lightweight aggregate deep beams strengthened with low-cost glass fiber-reinforced polymer composite (Lo-G) wraps as an alternative to expensive synthetic fiber-reinforced polymers (FRPs). The investigation includes side-bonded and fully wrapped configurations of Lo-G wraps, alongside carbon FRP (CFRP) strips for comparison. The experimental results show that epoxy-based anchors provided significantly better resistance against de-bonding than mechanical anchors, improving beam performance. Strengthening with Lo-G wraps resulted in a peak capacity increase of 17.0% to 46.9% for side-bonded beams in Group 2, 10.5% to 41.4% for fully wrapped beams in the strip configuration in Group 3, and 15.4% to 42.7% for CFRP strips in Group 4. The ultimate deflection and dissipated energy were also improved, with dissipated energy increases of up to 264.6%, 322.3%, and 222.7% for side-bonded and fully wrapped Lo-G wraps and CFRP strips, respectively. The side-bonded configuration with two or three Lo-G wraps, supplemented by epoxy wraps, outperformed fully wrapped 250 mm strips in peak capacity, with peak capacity improvements of up to 46.9%. However, beams with mechanical anchors showed poor performance due to premature debonding. They rely on friction and expansion within the concrete to resist pull-out forces. If the surrounding concrete is not strong enough or if the anchor is not properly installed, it can lead to failure. Additionally, reducing strip spacing negatively impacted performance. Lo-G wraps showed an 8.5% higher peak capacity and 32.8% greater dissipated energy compared to CFRP strips. Despite these improvements, while Lo-G wraps are a cost-effective alternative, their long-term performance remains to be investigated. None of the existing models accurately predicted the shear strength contribution of Lo-G wraps, as the lower elastic modulus and tensile strength led to high deviations in prediction-to-experimental ratios, underscoring the need for new models to assess shear strength. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Development of stress-strain models for glass fiber reinforced polymer composites confined sustainable concrete made with natural and recycled aggregates(2024-02-16) ;Yooprasertchai, Ekkachai; ;Hussain, Qudeer ;Khan, KaffayatullahEjaz, AliThis study addresses the mechanical limitations of concrete fabricated with recycled brick and concrete as partial replacement of coarse aggregates, which exhibit inferior strength and stiffness compared to those with natural aggregates. To rectify this, a cost-effective approach involving low-cost glass fiber-reinforced polymer composites (LOC-GFRP) is proposed. The key parameters considered were the plain concrete compressive strength and the quantity of LOC-GFRP layers. The compressive strength of LOC-GFRP-confined concrete increased with the number of layers, with greater improvements observed in lower-strength plain concrete. Moreover, the improvement in ultimate strain was more significant than the improvement in compressive strength. The compressive strength and ultimate strain were improved by 271% and 478%, respectively. LOC-GFRP confinement resulted in a bilinear compressive stress vs. strain response, showcasing increased ductility and strength with more LOC-GFRP layers. The study evaluated various existing analytical expressions for fiber-reinforced polymers but found them inadequate in predicting parameters accurately. As a result, nonlinear regression analysis was carried out to propose expressions for predicting compressive strength and ultimate strain of LOC-GFRP-confined concrete for different aggregate types. The calculated coefficient of determination values ≥ 0.90 confirmed the good correlation among experimental and predicted values. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental Investigations of Cement Clay Interlocking Brick Masonry Structures Strengthened with CFRP and Cement-Sand Mortar(2023-03-01) ;Joyklad, Panuwat ;Waqas, Hafiz Ahmad ;Hafeez, Abdul ;Ali, NazamEjaz, AliMany masonry structures are constructed with cement clay interlocking brick (CCIB) due to its added benefits. Recent research has demonstrated the vulnerability of brick masonry walls against seismic loading. Various strengthening materials and techniques are extensively used to improve the structural behavior of brick walls. Carbon fiber-reinforced polymer (CFRP) composites are the most popular strengthening material due to their advantages of easy application, lightweight qualities, and superior tensile strength. The current research work aimed to explore the cost-effective solutions and feasibility of CFRP composite-based strengthening techniques to improve the load-bearing capacity of CCIB walls. Various configurations and combinations of strengthening materials were investigated to customize the cost of repair and strengthening. The experimental results indicated that CFRP composites in combination with cement-sand (CS) mortar are an efficient strengthening material to enhance the strength and ultimate deflection of CCIB walls. The ultimate load-bearing capacity and axial deformation of the strengthened CCIB wall (using two layers of CFRP strips and CS mortar of 10 mm thickness) remained 171% and 190% larger than the unstrengthened CCIB wall. The conclusions of this study are expected to enhance the seismic performance of masonry buildings in developing countries. It should be noted that due to the reduced number of tested specimens, the results to be assumed as general considerations need a wider experimental campaign and a large numbers of tests for each strengthening typology. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Load-Bearing Performance of Non-Prismatic RC Beams Wrapped with Carbon FRP Composites(2023-06-01) ;Suparp, Suniti ;Ejaz, Ali ;Khan, Kaffayatullah ;Hussain, QudeerJoyklad, PanuwatThis study investigated the influence of CFRP composite wrapping techniques on the load–deflection and strain relationships of non-prismatic RC beams. A total of twelve non-prismatic beams with and without openings were tested in the present study. The length of the non-prismatic section was also varied to assess the effect on the behavior and load capacity of non-prismatic beams. The strengthening of beams was performed by using carbon fiber-reinforced polymer (CFRP) composites in the form of individual strips or full wraps. The linear variable differential transducers and strain gauges were installed at the steel bars to observe the load–deflection and strain responses of non-prismatic RC beams, respectively. The cracking behavior of unstrengthened beams was accompanied by excessive flexural and shear cracks. The influence of CFRP strips and full wraps was primarily observed in solid section beams without shear cracks, resulting in enhanced performance. In contrast, hollow section strengthened beams exhibited minor shear cracks alongside the primary flexural cracks within the constant moment region. The absence of shear cracks was reflected in the load–deflection curves of strengthened beams, which demonstrated a ductile behavior. The strengthened beams demonstrated 40% to 70% higher peak loads than control beams, whereas the ultimate deflection was increased up to 524.87% compared to that of the control beams. The improvement in the peak load was more prominent as the length of the non-prismatic section increased. A better improvement in ductility was achieved for the case of CFRP strips in the case of short non-prismatic lengths, whereas the efficiency of CFRP strips was reduced as the length of the non-prismatic section increased. Moreover, the load–strain capacity of CFRP-strengthened non-prismatic RC beams was higher than the control beams. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Prediction of Stress–Strain Curves for HFRP Composite Confined Brick Aggregate Concrete under Axial Load(2023-02-01); ;Ejaz, Ali ;Ali, Nazam ;Nawaz, AdnanHussain, QudeerRecently, hemp-fiber-reinforced polymer (HFRP) composites have been developed to enhance the strength and ductility of normal and lightweight aggregate concrete along with recycled brick aggregate concrete. In addition, both experimental and analytical investigations have been performed to assess the suitability of the existing strength and strain models. However, the theoretical and analytical expressions to predict the stress–strain curves of HFRP-confined concrete were not developed. Therefore, the main objective of this study was to develop analytical expressions to predict the stress–strain curves of HFRP-confined waste brick aggregate concrete. For this purpose, a new experimental framework was conducted to examine the effectiveness of HFRP in improving the mechanical properties of concrete constructed with recycled brick aggregates. Depending on the strength of the concrete, two groups were formed, i.e., Type-1 concrete and Type-2 concrete. A total of sixteen samples were tested. The ultimate compressive strength and strain significantly increased due to HFRP confinement. Improvements of up to 272% and 457% in the ultimate compressive strength and strain were observed due to hemp confinement, respectively. To predict the ultimate compressive strength and strain of HFRP-confined concrete, this study investigated several existing analytical stress–strain models. Some of the strength models resulted in close agreement with experimental results, but none of the models could accurately predict the ultimate confined strain. Nonlinear regression analysis was conducted to propose expressions to predict the ultimate compressive strength and strain of HFRP-confined concrete. The proposed expressions resulted in good agreement with experimental results. An analytical procedure was proposed to predict the stress–strain curves of hemp-confined concrete constructed by partial replacement of natural coarse aggregates by recycled fired-clay brick aggregates. A close agreement was found between the experimental and analytically predicted stress–strain curves. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Hybrid B-CSM Composites Strengthening Approach for Improved Stress–Strain Behavior of Concrete Columns and Development of Analytical Models(2025-02-01) ;Thansirichaisree, Phromphat ;Mohamad, Hisham ;Zhou, Mingliang ;Ejaz, AliThe brittle behavior of concrete under axial compressive loading has been a persistent issue. This study investigates the effectiveness of a hybrid Basalt-E-glass confinement (B-CSM) in improving the compressive behavior of concrete. The B-CSM confinement demonstrates a considerable improvement in ultimate strength and strain capacity by over 250 and 500%, respectively, making it a favorable solution for enhancing the ductility of concrete structures. Specimens at 18.43 MPa unconfined strength, confined with 3-layer B-CSM, demonstrated a 258% ultimate strength enhancement. For 24.43 MPa specimens, the same confinement resulted in a 207% increase in ultimate strength. Specimens with an initial ultimate strain of 18.43 MPa, when confined with 3-layers, showed a notable 516% increase. Likewise, for 24.43 MPa specimens, the same confinement led to a significant 395% improvement in ultimate strain. The use of B-CSM confinement is also effective in terms of cost compared to synthetic fiber-reinforced polymer jackets, and its availability is widespread. Existing analytical models for fiber-reinforced polymer confinement were evaluated, and it was found that these models could not predict the ultimate strength and strain of B-CSM-confined concrete. Therefore, this study proposes a unique regression-based approach for predicting the various points of the compressive stress vs. strain curve of B-CSM confinement. These points are then used to trace the complete stress vs. strain curve, which matches closely with experimental results. This work contributes to the development of new design recommendations for B-CSM confined concrete structures, which can enhance the performance of concrete structures and potentially reduce construction costs. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhancing the flexural behavior of brick masonry walls with ferrocement overlays and low-cost anchors(2023-12-01); ;Hlaing, Hnin Hnin ;Suwannatrai, Rawirot ;Ejaz, AliHussain, QudeerThis study presents an innovative approach to enhance the flexural capacity of cement-clay interlocking (CCI) brick walls using ferrocement jackets with an expanded wire mesh. The investigation involved 15 CCI brick walls subjected to flexural load testing, exploring various mesh sizes and anchor configurations on single and dual sides. The results revealed that while the primary failure mode involved dry joint opening and subsequent ferrocement debonding in the strengthened walls, effective anchorage mechanisms delayed dry joint opening until debonding occurred. The reinforced walls exhibited improved peak load capacity, notably in dual-sided reinforcement cases. With plastering on both sides and supplemented with anchors, an improvement of up to 221% in flexural capacity was obtained. The study emphasizes the influence of wire mesh size on anchorage effectiveness and its correlation with debonding susceptibility. Additionally, the moment-curvature analysis demonstrated resilient, ductile responses in load-bearing characteristics, with occasional abrupt declines due to ferrocement jacket debonding. Unlike control walls, the strengthened walls exhibited strains exceeding yield thresholds, indicating enhanced structural performance. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Cost-effective FRP solutions for enhancing strength and strain of sustainable concrete made with waste tyre rubber(2026-12-01); ;Chatveera, Burachat ;Hussain, Qudeer ;Sua-iam, GritsadaChaimahawan, PreedaThis study investigates the compressive behavior and analytical modeling of natural and rubberized concretes confined with cost-effective glass fiber-reinforced polymer (GFRP) jackets. Forty-two cylindrical specimens were tested under axial compression, including natural aggregate concrete (NAC) and rubberized concretes (RuC) prepared with 20% fine aggregate replacement using coarse (2.0 mm) and fine (0.425 mm) waste tire rubber. Both full and strip GFRP wrapping configurations with two, four, and six layers were examined. The results showed that GFRP confinement substantially enhanced both strength and ductility, transforming brittle failure into a gradual, energy-absorbing response. Full wrapping produced up to 63% and 90% strength increases for NAC and rubberized concretes, respectively, with ultimate strain gains exceeding 1300% in the fine-rubber mix. Strip wrapping achieved moderate yet significant improvements while offering material savings. Analytical models were developed for both concrete types to predict confined stress–strain behavior, achieving strong correlations (R<sup>2</sup> = 0.84–0.99) between predicted and experimental data. The derived regression-based formulations successfully captured the influence of confinement pressure, rubber content, and wrapping configuration. These findings demonstrate that GFRP provides an economical and sustainable confinement solution for enhancing the performance of rubberized concrete in structural and retrofitting applications. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Influence of recycled electronic waste fiber on the mechanical and durability characteristics of eco-friendly self-consolidating mortar incorporating recycled glass aggregate(2025-07-01); ;Chatveera, Burachat ;Roopchalaem, Jutatip ;Hussain, QudeerEjaz, AliIn the paper, the sustainable production of eco-friendly self-consolidating mortar (SCM) is explored with waste glass as a partial and complete substitution for fine aggregate owing to crucial environmental concerns. For that, the waste glass was replaced at 0 %, 25 %, 50 %, 75 %, and 100 %, while electronic waste fibers were added at 5, 10, and 15 % levels. Results showed that mini slump flow values varied between 233 mm and 263 mm, which confirmed the self-consolidating properties of the material even at 100 % replacement of fine aggregates and an addition of 15 % fiber. The increase in waste glass replacement reduced compressive strength; notably, a 30 % decrease was identified at the maximum substitution level of 100 %. Meanwhile, the mixtures incorporating 5 % fibers demonstrated the highest compressive strength at all maturation periods and replacement levels, even more markedly than the control mixture. The water absorption also increased significantly with increasing waste glass levels, up to 28.87 % at 100 % replacement, indicating increased porosity. Thermal conductivity decreased substantially, ranging from 1.97 W/mK for the control to 1.39 W/mK for 100 % replacement, which could be considered an improvement in insulation properties. These results show the possibility of using waste glass and electronic waste fibers to develop green SCM with enhanced thermal insulation and optimized mechanical properties. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Synergistic effect of recycled E-waste fiber and polyvinyl alcohol on the properties of green concrete incorporating recycled concrete aggregate(2025-10-01) ;Chatveera, Burachat ;Ejaz, Ali ;Hanif, Muhammad Adnan; Hussain, QudeerThe growing demand for sustainable construction highlights the need for innovative concrete solutions using waste materials. Although recycled concrete aggregate (RCA), polyvinyl alcohol (PVA), and recycled electronic waste fibers (E-waste fibers) have been studied individually, their combined effects remain underexplored. This study addresses this gap by investigating the synergistic effects of coarse RCA (CRCA) and E-waste fibers on the fresh, mechanical, durability, thermal, and economic properties of green concrete. Fly ash replaced 20 % of cement, and PVA was added at 1 % by cement weight. Results showed that increasing CRCA content reduced workability and strength due to porosity. However, incorporating 4.5 % E-waste fibers significantly improved mechanical performance by bridging microcracks. Higher fiber contents negatively affected durability and workability. Thermal conductivity decreased with more CRCA and fibers, enhancing insulation. Economic analysis confirmed that 4.5 % E-waste fiber offers cost-effective performance. This study supports the sustainable use of electronic and construction waste in concrete.
