Now showing 1 - 10 of 30
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Portable holgraphic imager for biological samples
    (2014-01-20)
    A portable holographic imaging platform combining with an automatic micro-objects detection algorithm is demonstrated for biological samples. All components of the imaging platform are aligned to one another along the same optical axis, provides many advantages such as large field-of-view, simple optical setup, and no optical aberration. Main features in the software are feature detection and counting. The average overall computational time is of 52.37 seconds, specificity and sensitivity of our algorithms on a 2593×1944 pixels hologram are 0.978 and 0.923 respectively. Although the algorithm is not optimized, the technique here only focuses on the detection and counting problem.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Three-dimensional microscopy of biopsies with a handheld confocal microscope
    (2015-10-02)
    Intravital confocal microscopy has provided powerful mechanistic insights into health and disease with three-dimensional imaging capability and has become a common imaging instrument in the modern biological laboratory and clinic. However, the requisite of high numerical aperture, short working distance, and small field of view that enable confocal microscopy limit the ability to investigate hollow organs in vivo. Here we introduce a handheld confocal microscope that circumvents the above technical limitations of confocal microscopy and, as a result, provides imaging access to variety tissues in vivo. The handheld microscope achieves its miniaturization with micro-optics and microelectromechanical systems scanner technology enabling a small form factor and 3-D imaging performance.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Image mosaicing and real-time imaging with MEMS based handheld confocal microscope
    (2014-01-01)
    In this paper, we demonstrated a handheld confocal fluorescence microscope using dual-axis confocal architecture with a microelectromechanical systems (MEMS) scanner. The laser sources for the microscope are both in visible (660 nm) and near-infrared (778 nm) wavelengths. The microscope will be used for in vivo cervical cancer screening in real-time with human patients. The maximum imaging depth is over 300 μm into the tissue for epithelial cancer screening. The maximum field of view (FOV) is 550 μm × 500 μm with 14 frames/second.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Centralized pap test diagnosis with artificial neural network and internet of things
    (2016-07-02)
    Dumripatanachod, Manatchakorn
    ;
    In this work, we propose a utilization of a serverclient system model that using the Internet of Things (IoT) technology to process Pap smear imaging data derived from high-resolution microscopes and to classify the those images by employing the Artificial Neural Network (ANN) learning algorithm on the server. The IoT can enable those microscopes to communicate with one another while the ANN enables a new method of imaging classification with high accuracy. We utilize 917 high-resolution images as an input for our proposed method. The method achieves a root mean square error of 0.8834 and correlation coefficient of 0.6643.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    3CA-FO: Budget stereoscopic 3D imaging colposcope
    (2023-01-01)
    Amnuayphol, Nontiwat
    ;
    ;
    Piyawattanametha, Nicholas
    This research aims to develop an advanced medical device designed to enhance the diagnostic quality of conventional colposcopy. The device utilizes cutting-edge technologies, including 3D image synthesis via stereoscopic imaging and polarized glasses as the primary focus of the study is to improve cervical cancer. The research scope encompasses enhancing spatial information, The research scope involves enhancing spatial information while allowing the doctor to maintain the advantage of near vision and enabling multi-angle imaging. The hardware of the colposcope is based on the design from Duke University's 2018 research. Our 3D Cervical Assessment - Fine-tuned Optics colposcope (3CA-FO) is capable of providing real-time 3D imaging with precise calibration, achieved through the utilization of the Embedded Mono Calibration for Heterogeneous Lenses technique. This ensures an instantaneous and high-quality 3D output response.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Evaluation of rapid detection system for Escherichia coli in water samples
    (2017-02-21)
    Pipitsombat, Chanikarn
    ;
    Phasuk, Kanchana
    ;
    ;
    We demonstrated a fast detection platform for Escherichia coli (E. coli) in water. The system is based on a fluorescence detection technique by determining enzyme β-D-glucuronidase (GUD) activity and relating that activity to E. coli concentration. We found the portable E. coli detection platform is able to detect both the fluorescence 4-MU signal from the reaction of GUD assay from 0.01-1 μg/ml and to enumerate the number of E. coli in the range of 10<sup>5</sup>-10<sup>7</sup> CFU/ml. The required incubation time is in between 20-240 min. In addition, we can estimate the maximum of incubation time for detecting minimum of E. coli 1 CFU/ml from the equation to be 576 mins. Our preliminary study demonstrates that the system can be used to enumerate the number of E. coli in water on-site and requires less detection time than traditional E. coli methods.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Fluorescence based rapid E. coli Detector
    (2021-01-01)
    Chantharasuriyasakun, Thitiyo
    ;
    Sungwol, Siriyakorn
    ;
    We have developed a fluorescence based rapid detection for E. coli which is an indicator for water quality identification. This portable detector will trim down the time taken to detect E. coli in the water from a few days to just a couple of minutes. Moreover, with the use of enzyme-substrate reaction between the enzyme β-D glucuronidase (GUD) in the E. coli and the substrate 4-methylumblliferyl-β-D glucuronide (MUG) resulting in a byproduct of 4-methylumbellliferone (4MU), the fluorescence emitting from this byproduct is then detected by our system and be enumerated for the number of E. coli. Hence, we have tested our system with two different pH solution, distilled water and tap water with pH values at 6.68 and 7.81 consecutively. Our developed system can detect the byproduct of 4MU in the concentration range of 0.001 μ M to 2 μM for the distilled water and 0.001 μM to 0.1 μM for the tap water, which can then be used for the enumeration of E. coli.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    An ultra-violet sterilization robot for disinfection
    (2019-07-01)
    Chanprakon, Pacharawan
    ;
    Sae-Oung, Tapparat
    ;
    ; ;
    Ultraviolet (UV) sterilization technology is used to aid in reduction of microorganisms that may remain on the surfaces after a standard cleaning to the minimum number. Our research team developed a UV robot or UV bot for sterilization in an operating or a patient room. Our UV bot has three 19.3-watt of UV lamps mounted on top of the UV bot platform covering 360° direction. Our UV bot employed an embedded system based on a Raspberry Pi to aid in navigation to avoid obstacles. In addition, we tested the effectiveness of eliminating Staphylococcus Aureus bacteria sample plates located 35 cm away from our UV bot to be within 8 seconds after UV light exposure.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Development of a Low-Cost Raman Spectrometer for Non-Invasive Molecular Mapping
    (2024-01-01)
    Tangkiatphaibun, Parawee
    ;
    Suttikittipong, Pasin
    ;
    Udomtanasub, Pholchanok
    ;
    Piyawattanametha, Nicholas
    ;
    Non-communicable diseases like diabetes continue to be major global health challenges, traditionally managed through invasive glucose monitoring methods. To address this, our research focuses on developing a DIY Raman spectrometer enhanced with a fiber laser for non-invasive glucose detection. Utilizing Surface-Enhanced Raman Spectroscopy (SERS) with a SERS S440 substrate at 500 ppm, we successfully achieved Raman mapping and demonstrated the capability to capture Raman shifts across various samples. The mapping results indicate the system's effectiveness in visualizing molecular composition, laying a strong foundation for future integration of SERS multiplexing to further enhance sensitivity and enable simultaneous detection of multiple analytes. This approach presents a cost-effective and accessible solution, showcasing the potential of advanced Raman spectroscopy in diabetes care and non-invasive monitoring technologies. Our work represents a significant step toward improving the accessibility and accuracy of glucose monitoring for patients globally.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Whole slide imaging based on a low-cost camera
    (2018-08-13)
    Sasivimolkul, Suvicha
    ;
    Jittichaiwet, Tanakit
    ;
    This work presents a new low-cost digital single-lens reflex camera whole slide imaging (DC-WSI) system, which is the most recent imaging modality being employed by pathology departments worldwide due to its high-throughput routine and high-speed capabilities. The DC-WSI system field of view achieves 22.6 times larger than that of the equivalent magnification of a conventional microscope system. The DC-WSI is capable of performing the whole slide scanning (2 cm2) under 2 seconds.