Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Measurement of sucrose concentration using Imbibition length on paper: A device for equipment-free and environmentally-friendly detection
    (2024-04-01)
    Sitanurak, Jirayu
    ;
    Kumpong, Anongnat
    ;
    Yaimai, Orawan
    ;
    Wilairat, Prapin
    ;
    The Lucas-Washburn equation is commonly used to predict the distance (L) that a liquid travels through paper. This equation establishes that L<sup>2</sup> is linear with time and inversely proportional to the viscosity of the liquid. However, there is currently no theoretical equation connecting the viscosity of a solution to its concentration. In this study, the imbibition flow of a sucrose solution was measured along the length of a horizontal strip of filter paper, featuring a printed, thermometer-shaped hydrophobic boundary. A sample (38 μL) was dispensed onto the bulb area, and the solution's flow was visually tracked using a red dye added to the sample. The imbibition length (L) was measured by a vernier caliper at 10.0 min after the sample addition. An empirical equation, based on literature values of the viscosity (η) and concentration (C) of sucrose solutions, was proposed. By integrating this empirical equation with the Lucas-Washburn equation, the following equation was derived: L = a⋅exp{-(bC + cC<sup>2</sup>)}, where ‘a’, ‘b’ and ‘c’ are parameters. This equation was fitted to the dataset of L and C, covering C values from 0 to 60 % w/w standard sucrose solutions, resulting in a coefficient of determination of 0.9987. The plot of L against C was observed to closely follow a linear line, with a fitting providing a coefficient of determination of 0.9986. The sucrose contents in samples, such as soft drinks, syrups, and sugarcanes, determined using the imbibition length method and conventional refractometry, were in statistical agreement via the paired t-test at the 95 % confidence level. This method is simple, instrument-free, requiring only a small amount of safe red food dye, and can be conducted on-site.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Microfluidic paper-based analytical device for convenient use in measurement of iodate in table salt and irrigation water
    (2020-01-01)
    Duangdeewong, Chomphunud
    ;
    Sitanurak, Jirayu
    ;
    Wilairat, Prapin
    ;
    Nacapricha, Duangjai
    ;
    We report a convenient microfluidic paper-based analytical device (µPAD) for the determination of iodate. The µPAD was fabricated using an ink-stamp with a simple circle design. Colorimetric detection of iodate employs the oxidation of hydroxylamine by the iodate to generate nitrite which reacts with the Griess reagent producing an intense magenta color. The images were recorded by a digital camera, and converted to a green scale color intensity by ImageJ. Calibration of iodate was linear in the range of 50–400 mg L<sup>−1</sup> with a detection limit of 38.1 mg L<sup>−1</sup>. With such a wide linear range, the method can be applied to various kinds of samples with the entire process completed in 50 s. Good precision of measurement was obtained (<2 %RSD). Iodate levels were determined using the µPADs in table salt and irrigation water samples. The measured concentrations of the samples correlated well with the values as found by the standard iodometric titration (no statistical difference at a 95% confidence level). The developed device is simple with easy fabrication and rapid operation. It is portable and cost-effective and therefore suitable for quality control of iodate levels in the manufacturing and agricultural industries.