Tretriluxana, Suradej
Loading...
Preferred name
Tretriluxana, Suradej
Alternative Name
Tretriluxana, S.
Main Affiliation
Email
suradej.tr@kmitl.ac.th
24 results
Now showing 1 - 10 of 24
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Feasibility investigation of the accelerated skill acquisition program (ASAP): Insights into reach-to-grasp coordination of individuals with postacute stroke(2013-01-01) ;Tretriluxana, Jarugool ;Runnarong, Nuttakarn; ;Prayoonwiwat, NarapornVachalathiti, RoongtiwaBackground: Skill acquisition, capacity building, and motivational enhancements are the basis of the Accelerated Skill Acquisition Program (ASAP) and form the foundation for effective incorporation of the paretic upper extremity into life activities. This is the first phase I trial to deliver ASAP during the postacute interval in mildly to moderately impaired stroke survivors and to include an assessment of paretic reach-to-grasp (RTG) coordination using RTG task and cross-correlation analyses. Methods: Two baseline and posttreatment evaluations consisted of RTG actions, the Wolf Motor Function Test (WMFT), and the Stroke Impact Scale (SIS). An individualized arm therapy program using ASAP principles was administered for a total of 30 hours, 2 hours per day, for 2 to 4 days per week over 5 weeks. Dependent measures were kinematics of RTG actions, RTG coordination, total time score of WMFT, and stroke recovery score of SIS. Results: All participants tolerated ASAP well, and none reported any adverse effects during or after the protocol. When the 2 baseline evaluations were compared, there were no changes in any RTG kinematics or RTG coordination. In contrast, after 30 hours of ASAP, total movement time and deceleration time of RTG actions markedly decreased, maximum reach (transport) velocity strikingly increased, and time of maximum aperture was accomplished later. Additionally, the maximal RTG correlation coefficient increased with a shorter associated time lag. A similar pattern was observed for the clinical outcome measures of WMFT and SIS. Conclusions: The findings demonstrate the feasibility of using an ASAP protocol for patients 1 to 3 months post stroke. Under ASAP, WMFT tasks and RTG actions were performed faster with higher peak transport velocity and a more coordinated RTG pattern. The next step is to determine whether the immediate gains in the skilled RTG actions persist 6 months alter. © 2013 Thomas Land Publishers, Inc. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of Class Weights on Imbalanced Classes in Bi-directional LSTM Training for Sleep Apnea Classification(2024-01-01) ;Jansri, UkkritSleep apnea, which is defined as the repetitive cessations of breathing during sleep, is the common disorder worldwide. The cost and the process of sleep test to obtain the polysomnogram is not optimal for sleep apnea screening in the large population. A deep learning model was developed to classify the normal and apnea events in a single time-series signal exported from the US National Institute of Health (NIH) sponsored database. Our challenge was to train the model with imbalanced dataset between normal and abnormal respiratory events. Three different methods, Synthetic Minority Over-sampling Technique (SMOTE), Random Under-Sampling (RUS), and the Class Weights (CW) were chosen to improve the model performance over the original data on five selected signals from polysomnographic dataset. The binary classification outputs were evaluated by four metrics. Our results showed (1) Matthews Correlation Coefficient was highest (MCC= 0.1385) in the Class Weights method on the nasal airflow signal. (2) Cohen's Kappa score, was highest (k= 0.0819) in SMOTE technique on the abdominal signal, followed by the Class Weights method on the abdominal signal (k= 0.0687) and RUS technique on nasal airflow signal (k= 0.0441). (3) F1-score was highest (F1= 11.89%) in SMOTE technique on the abdominal signal, followed by the Class Weights method on nasal airflow signal (F1 = 11.17%) and RUS technique on nasal airflow signal (F1= 9.16%). The findings suggest that the Class Weights method on nasal airflow and the Class Weights method on abdominal signal were the two combinations to be used in the DL model. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effects of repetitive transcranial magnetic stimulation combined with action-observation-execution on social interaction and communication in autism spectrum disorder: Feasibility study(2023-04-01) ;Kaokhieo, Jirapimon ;Tretriluxana, Jarugool ;Chaiyawat, Pakaratee ;Siripornpanich, VorasithPermpoonputtana, KannikaObjective: To investigate the feasibility of a combined high-frequency rTMS (HF-rTMS) with action observation and execution (AOE) on social interaction and communication in children with Autistic Spectrum Disorder (ASD). Materials and methods: Fifteen children underwent 10 sessions of 5-Hz HF-rTMS on the right inferior frontal gyrus combined with AOE. An experimental group received the real HF-rTMS while the control group received the sham one. For the AOE protocol, they were instructed to watch and imitate a video showing the procedure, including reaching and grasping tasks, gustatory tasks, and facial expressions. Their behavioural outcomes were evaluated using the Vineland Adaptive Behaviour Scale (VABS) and electroencephalograms (EEGs) recorded at three time points: baseline, immediately after each treatment, and at the 1-week follow-up after the 10th treatment. Results: There was a reduction in the VABS subitem scores of the experimental group, including the receptive, expressive, domestic, and community scores but no such reductions were observed in the control group. For the EEG, the beta rhythm at C3 and C4 increased in the experimental group. Additionally, positive correlations were observed between changes in the scores for the expressive subitem and changes in the beta rhythm on the C4 electrode at baseline and immediately after treatment in the experimental group. The control group showed no significant differences in any items for both observation and imitation times. Conclusion: Ten sessions of HF-rTMS combined with AOE could improve both the subitems of communication and daily living skills domain in children aged 7–12 years with ASD. Although it is still inconclusive, this behavioural improvement may be partly attributable to increased cortical activity, as evidenced by beta rhythms. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Evaluating Marker-Based and Markerless Motion Capture Systems in Reach-to-Grasp Task(2024-01-01) ;Liangsorn, NatsakornThis study evaluated the accuracy of marker-based versus markerless motion capture systems in tracking reach-to-grasp movements, using an electromagnetic tracking system as the gold standard. Reach-to-grasp tasks are fundamental activity in daily activities and often affected by neurological conditions like stroke, highlighting the importance of accurate measurement in rehabilitation research. The findings show that the marker-based system consistently outperformed the markerless system, with significantly lower root mean square errors (RMSE) across all axes. The marker-based system achieved an average RMSE of 4.55 millimeters (mm), demonstrating clinical-level accuracy, while the markerless system averaged 23.64 mm, indicating limitations in its ability to track movements with high accuracy. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of Resampling Techniques on Deep Learning Model Training in Sleep Apnea Classification(2022-01-01) ;Jansri, UkkritThis study is using deep learning model to classify the respiratory events of Sleep Disordered Breathing (SDB) data. Our pilot results showed the missed identification in some classes even the total accuracy is high. This is the result of unbalanced training dataset given to the model. Two different resampling techniques; Synthetic Minority Over-sampling Technique (SMOTE) and Random Under-Sampling (RUS), were introduced to balance the data. One hundred overnight nasal airflow signals were randomly selected from NIH funded polysomnography database. They were used to train and test these two algorithms with Bi-directional Long Short-Term Memory (Bi-LSTM) model. The results showed greater agreement index when compared between with and without data resampling process. However, SMOTE in sum performed better than RUS (93.72% vs 70.01% in overall accuracy and 0.91 vs 0.55 in Cohen's kappa). It demonstrates that the over-sampling technique is more powerful than under-sampling one. Other resampling techniques will be investigated to make the robust conclusion. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A design of configurable ECG recorder module(2011-12-01) ;Punapung, Anucha; Chitsakul, KitipholA modular design of Electrocardiogram (ECG) acquisition system is presented. As a crucial part of the system, the Front-End module is made of a programmable, mixed-signal Application Specific Integrated Circuit (ASIC). This module is designed to satisfy the various forms of bioelectrical measurement with no hardware modification. Controlled by a 32-bit microcontroller, the prototype module recorded the simulated signal in two different standard ECG recording configurations, ten and six electrodes placements. Our study shows a good performance signal recording and the module is open to further developed. © 2011 IEEE. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Reach-to-Grasp Motion Tracking System Using Single Smart Phone Camera(2022-01-01) ;Thongprasan, Sahawatchara ;Liangsorn, Natsakorn ;Raden-Ahmad, Chafik ;Kongkaew, KotchakornTretriluxana, JarugoolAssessment of human movement is necessary for physical therapy management. This article presents a development of motion tracking system for human Upper Extremity (UE) function analysis. We proposed the optical motion capture system made by a single smart phone camera. It was used to capture the Reach-to-Grasp (RTG) movement of participants in sitting position. Image processing were used to detect color markers placed on chosen hand anatomical landmarks. With our simple camera calibration technique, the 3D coordinates of hand movement were obtained. Two clinical parameters, grasp aperture and hand transport velocity were computed. These results were compared with the outputs, collected at the same time, from the higher accuracy Electromagnetic Motion (EM) tracking system. Qualitatively, the result patterns from two systems were parallel to each other. Our ongoing work is to improve the algorithms according to the feedback from clinicians. This system may provide implication for physical therapist to assess the clients' movement in the clinical setting. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Comparison of Heart Rate statistical parameters from Photoplethysmographic signal in resting and exercise conditions(2015-08-17) ;Sengthipphany, T.; Chitsakul, K.The aim of this article is to investigate the possibility of computing Heart Rate Variability (HRV) indices from the finger Photoplethysmogram. To indicate that whether Pulse Rate Variability (PRV) from PPG signal can be used as an alternative to Heart Rate Variability (HRV) from ECG signal. The Photoplethsmographic (PPG) and Electrocardiographic (ECG) signals from 33 participants were recorded simultaneoussly during resting and exercise conditions. The peaks of PPG and R-waves of ECG were detected and reconstructed to the Peak-to-Peak interval (PPI) and R-to-R interval (RRI) waveforms respectively. In both conditions, the mean and standard deviation (SDNN) of the intervals over 5 minutes were computed from the two waveforms. Results from cross correlation between PPI and RRI show that the average correlation coefficients (r) are higher in resting than the 'r' in exercise. In regression analysis of the statistical parameters between RRI and PPI, the determination coefficients (R<sup>2</sup>) of the means are close to one in both conditions, whereas the R<sup>2</sup> of SDNN in exercise is lower than the one in resting. This finding suggests that the HRV indices can be evaluated from PPG with reliability during the rest. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Brainwave spectrum analysis during paced breathing control: A pilot study(2017-02-21) ;Pakoktom, Nipawan; Chitsakul, KitipholInvestigation of Electroencephalogram (EEG) has been made during the spontaneous breathing and paced breathing control (9 breaths/minute) conditions in eight young healthy college students (Male=4, Female=4). Their selected 5-minute EEG segments were transformed into 3 frequency bands (Delta Wave: 0.5-4Hz, Theta Wave: 4-8Hz and Alpha Wave: 8-13Hz). The power in each band were compared between two conditions. Our statistical tests show no significant differences between the two conditions in all three spectrums. This pilot study needs to be further analyzed to make a firm conclusion and a larger sample size is suggested. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of Heart Rate Variability and Breath to Breath Interval in frequency domain(2014-01-20) ;Sengthipphany, Tick; Chitsakul, KitipholRespiratory is known to be a confounding factor of Heart Rate Variability (HRV) analysis. This article introduces a Breath-to-Breath Interval (BBI) spectral computation to investigate the insight between respiration and the HRV. Six males and five female volunteers (age 20-25 years) underwent the Electrocardiogram (ECG) and respiratory chest movement recordings for 5 minutes while sitting in resting condition. Auto Regressive Moving Average (ARMA) model was employed to the R-wave to R-wave interval (RRI) and BBI signals for the spectral analysis. The results from all participants demonstrate that the peak amplitude in high frequency (0.15-0.40 Hz) band are higher than the ones in low frequency (0.04-0.15 Hz) band in both RRI and BBI frequency plots. It suggests that respiratory plays a major role in HRV oscillation. Our further study is to develop a mathematical model to explain this finding.
