Jayranaiwachira, Nuthvipa
Loading...
Preferred name
Jayranaiwachira, Nuthvipa
Main Affiliation
Email
nuthvipa.ja@kmitl.ac.th
4 results
Now showing 1 - 4 of 4
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal effectiveness and entropy-exergy estimation in a tube with punched double V-winglets(2026-06-01); ;Sripattanapipat, Somchai; ;Erfanian Nakhchi, MahdiSkullong, SompolVortex generators are effective devices for enhancing heat transfer rates in heating or cooling systems with minimal frictional losses via the production of streamwise vortices. This research effort presents the perforated double V-winglet (P-DVW) and looks at how it affects heat transmission and friction when mounted inside a heat exchange tube that is consistently heated for producing multiple vortices whereas its flow is turbulent. Optimizing thermal performance for increased energy savings and maximizing the Nusselt number ( Nu ) to minimize heat exchanger size are the major goals. Thermal characteristics, including generated entropy and exergy efficiency, are explored in depth. A Reynolds number (Re) that varies from 4760 to 29,270 is employed to explore the friction and thermal features of the tube. The P-DVW parameters encompass attack angles of α<inf>2</inf> = 15° and α<inf>1</inf> = 30°, four porosity ratios ( A <inf>h</inf>/ A <inf>w</inf> = 0, 0.0188, 0.0523, and 0.1026), and three pitch ratios, P<inf>R</inf>, (0.75, 1, and 1.25), while maintaining a constant winglet height. At P<inf>R</inf> = 0.75 and A <inf>h</inf>/ A <inf>w</inf> = 0, the P-DVW exhibits peak f and Nu values around 23.83 and 5.31 times bigger than those of the plain tube, accordingly. Further, under the specified conditions, it yields minimal entropy production, while the optimal exergy efficiency is roughly 0.9829. The thermal effectiveness of P-DVW is anticipated to reach its maximum at 2.55 with Nu<inf>R</inf> = 4.54 at A <inf>h</inf>/ A <inf>w</inf> = 0.0523 and P<inf>R</inf> = 0.75 to reveal its actual benefits. Furthermore, the correlations of f , Nu , and TEF were determined for the examined range of values. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical Heat Transfer Investigation in a Heat Exchanger Tube with Hexagonal Conical-ring Inserts(2016-11-01) ;Sripattanapipat, Somchai ;Tamna, Sombat; The hexagonal conical rings (HCR) modified from the typical conical ring (CR) are used as a turbulence promoter for producing the vortex flows to enhance the heat transfer rate in a heat exchanger tube. To reduce the pressure loss, the V-shaped HCR (V-HCR) obtained by cutting both symmetric plane of the cone-tip of HCR at 30°, 45°and 60°is offered in the present work. The tube fitted with V-HCR elements having a fixed inlet and outlet diameter is numerically investigated. The computation is carried out for Reynolds number in a range of 3000 to 20,000 in a uniform heat-fluxed test tube. The numerical results show that the V-HCR insert leads to much higher heat transfer than the typical CR/HCR insert or the smooth tube alone and also provides lower friction factor. The 30°V-shaped HCR gives the highest heat transfer and thermal performance due to the lowest friction loss, indicating the promising device of the V-HCR. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmentation of solar air heater effectiveness with flapped triangular-wings(2025-12-01); ;Sripattanapipat, Somchai; ;Nakhchi, Mahdi ErfanianSkullong, SompolAn experiment was conducted to identify the optimal method for enhancing the thermal effectiveness of a solar air heater duct utilizing flapped triangular-wing (FTW) vortex generators affixed to the absorber. The wings are structured in two configurations: backward FTW (B-FTW) and forward FTW (F-FTW), each incorporating a louver-flapped opening for lowering frictional loss. This study seeks to improve the Nusselt number ratio (Nu<inf>R</inf>) while lowering friction loss to optimize thermal effectiveness, hence minimizing the overall dimensions of thermal energy systems. The research findings focus on heat transmission (Nu) and frictional loss (f), encompassing thermal effectiveness across the entire range of Reynolds numbers (Re) from 5280 to 22,510. The FTW elements are configured in B-FTW and F-FTW forms, employing three relative pitches (P<inf>R</inf> = 0.75, 1.25, and 1.75) and five flap angles (θ = 0°, 35°, 45°, 65°, and 90°), while maintaining a constant attack angle (α = 45°) and a wing height ratio (B<inf>R</inf> = 1). The research findings demonstrate that the FTWs produce a significant increase in Nu contrasted to the smooth duct, which varies from 4.72 to 8.05 times, while the increase in f is approximately 13 to 68.1 times. For P<inf>R</inf> = 1.25, θ = 45°, and lower Re, the greatest thermal effectiveness factor (TEF) is roughly 2.87 for the F-FTW and 2.64 for the B-FTW, while Nu<inf>R</inf> is approximately 6.98 for the F-FTW and 6.29 for the B-FTW. This implies that the largest TEF is exclusively associated with the F-FTW, and therefore, the B-FTW should be averted in practice. Additionally, correlations are established and documented for the key quantities (Nu, f, and TEF).