Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Linear Variable Differential Transformer Signal Conditioning Circuit Based on Phase-Locked Loop
    The purpose of this paper is to propose a novel technique for extracting the position signal from an inductive displacement transducer named a linear variable differential transformer (LVDT). In general, the movement of the LVDT core causes its primary inductance change in linear form. The primary winding of the LVDT is used as a time-dependent element for the triangular and square wave generator, which can be called self-oscillation, to generate frequency. The advantage of the proposed technique is that it can measure the displacement using the LVDT without an external oscillator. The change in primary inductance causes the frequency deviation generated by the oscillator. The deviated frequency is captured and converted into a voltage signal using the principle of the phase-locked loop. All the components used in this study are commercially available. The merits of this proposed technique are simple configuration, small size, and low cost. Moreover, the operating range of the LVDT can be extended without the limitation of the nonlinear transfer characteristic. The performance of the proposed technique is discussed in detail and confirmed by experimental implementation. Experimental results show that the maximum error from the proposed technique is about 0.42% and the operating range of the LVDT can be extended to more than 200%. It can be seen that the proposed technique is suitable for embedded measurement in small or micro robots.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Temperature Compensation for Transformer-type Transducer
    A novel technique to compensate the temperature effect of a transformer-type transducer is proposed in this paper. The effect of the ambient temperature on the transformer-type transducer is investigated from a primary-winding current. The advantage of the proposed technique is that the temperature effect is compensated without requiring a temperature sensor, making it suitable for applications in robotic and automation systems operated in harsh environments. The primary-winding current of the transducer is generated using a second-generation current conveyor (CCII). The excitation signal of the transformer-type transducer is driven by the CCII and the current flowing through the primary winding is transferred to an output signal of the CCII. The deviation of the primary-winding current due to the temperature effect is evaluated from the output signal of the CCII. The temperature effect on the transducer is manipulated by a closed-loop principle using a subtract-and-sum action instead of a traditional proportional-plusintegral action to eliminate the deviation of the primary-winding current. Therefore, the temperature effect on the transducer is compensated. A linear variable differential transformer (LVDT) is used to demonstrate the proposed technique, whose performance is discussed in detail and confirmed experimentally. All devices used in this experiment are commercially available. Experimental results show that the measured error of the output signal from the LVDT at 70 C can be reduced from 6.2% without temperature compensation to 0.06% by using the proposed technique, which has the advantages of a low cost, simple configuration, and high performance.