Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Shortwave near-infrared spectroscopy for rapid detection of aflatoxin B1 contamination in polished rice
Loading...
Thumbnail Image

Shortwave near-infrared spectroscopy for rapid detection of aflatoxin B1 contamination in polished rice

Author(s)
Putthang, R.
Sirisomboon, P.
Sirisomboon, C. Dachoupakan
Date Issued
January 1, 2019
Type
Article
DOI
10.4315/0362-028X.JFP-18-318
Abstract
The objective of this research was to apply near-infrared spectroscopy, with a short-wavelength range of 950 to 1,650 nm, for the rapid detection of aflatoxin B1 (AFB1) contamination in polished rice samples. Spectra were obtained by reflection mode for 105 rice samples: 90 samples naturally contaminated with AFB1 and 15 samples artificially contaminated with AFB1. Quantitative calibration models to detect AFB1 were developed using the original and pretreated absorbance spectra in conjunction with partial least squares regression with prediction testing and full cross-validation. The statistical model from the external validation process developed from the treated spectra (standard normal variate and detrending) was most accurate for prediction, with a correlation coefficient (r) of 0.952, a standard error of prediction of 3.362 µg/kg, and a bias of-0.778 µg/kg. The most predictive models according to full cross-validation were developed from the multiplicative scatter correction pretreated spectra (r = 0.967, root mean square error in cross-validation [RMSECV] = 2.689 µg/kg, bias = 0.015 µg/kg) and standard normal variate pretreated spectra (r = 0.966, RMSECV = 2.691 µg/kg, bias = 0.008 µg/kg). A classification-based partial least squares discriminant analysis model of AFB1 contamination classified the samples with 90% accuracy. The results indicate that the near-infrared spectroscopy technique is potentially useful for screening polished rice samples for AFB1 contamination. HIGHLIGHTS • Shortwave near-infrared spectroscopy allowed rapid detection of AFB1 in polished rice. • The partial least squares model provided the best accuracy for prediction (r = 0.967). • The partial least squares discriminant analysis model had a classification accuracy of 90%.
Citation
Journal of Food Protection, 82(5), 796-803, 2019
Subjects

Mycotoxin

Nondestructive method...

Partial least squares...

Rice

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback