Investigation of Very Low Frequency Dissipation Factor of the Contaminated Underground Cable Joints

Author(s)
Suksawat, Dusit
Hengcharoensuk, Tassana
Nupinit, Thanapon
Chusang, Kittidech
Ravangvong, Tanachot
Pattanadech, Norasage
Date Issued
October 25, 2020
Type
Conference Paper
DOI
10.1109/CMD48350.2020.9287210
Abstract
This paper presents the characteristics of the contaminated underground cable joints tested by a very low frequency voltage source. The underground cable system used in the experiment was comprised of a 12/20(24) kV underground cable with a cross-section area of 240 mm2, and the length of 6 m. Four different case studies were simulated on the cable joint, i.e., a healthy heat shrink cable joint (case 1), a cable joint with an incision on XLPE surface(case 2), a cable joint contaminated with 20-micron iron powder on XLPE surface(case 3), and a cable joint contaminated with 20-micron copper powder on XLPE surface(case 4). The dielectric dissipation factor, also known as tan δ at very low frequency (0.1Hz) of such underground cable systems, was examined at 0.5 U0, 1 U0, and 1.5 U0, respectively. The very low frequency(VLF) test voltage was applied to the cable specimen, according to IEEE 400.2(2013). The test voltage was recorded and analyzed. It was found that the cable joint contaminated with 20-micron iron powder on XLPE surface had a maximum tan δ. The tan δ value decreased respectively for the cable joint with an incision on XLPE surface and the cable joint contaminated with 20-micron copper powder on XLPE surface. The healthy heat shrink cable joint showed the lowest tan δ. It was clearly shown that the contaminated cable joint caused higher very low frequency tan δ compared with the healthy cable joint.
Citation
Proceeding 8th International Conference on Condition Monitoring and Diagnosis Cmd 2020, 342-345, 2020
Subjects

cable joints

tan δ

XLPE underground cabl...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback