Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Study of ionospheric topside variations based on NeQuick topside formulation and comparisons with the IRI-2012 model at equatorial latitude station, Chumphon, Thailand
Loading...
Thumbnail Image

Study of ionospheric topside variations based on NeQuick topside formulation and comparisons with the IRI-2012 model at equatorial latitude station, Chumphon, Thailand

Author(s)
Jamjareegulgarn, Punyawi
Supnithi, Pornchai
Hozumi, Kornyanat
Tsugawa, Takuya
Date Issued
July 15, 2017
Type
Article
DOI
10.1016/j.asr.2017.03.025
Abstract
It is well-known that the equatorial anomaly at equatorial and low latitudes is caused by the fountain effect, therefore, the modeling of topside electron density profiles (EDPs) and the knowledge of electron density distribution in the region are particular challenging. Chumphon station, Thailand, is located within this region. However, at this station, since only an FMCW ionosonde system is installed, the topside EDP cannot be automatically obtained. Therefore, in this work, the topside EDPs are derived using the NeQuick topside formulation of the NeQuick 2 model (namely, NeQuick-derived topside EDPs) and then compared with those of three options of the IRI-2012 model including NeQuick, IRI01-corr, and IRI2001 options. The results show that, at Chumphon station, the NeQuick-derived topside EDPs are generally closer to the topside EDPs of IRI01-corr option in winter season and the topside EDPs of NeQuick option in equinox and summer seasons. When analyzing the topside TEC values obtained from each profile and the IGS TEC, it is found that the topside TEC values integrated from NeQuick-derived topside EDPs and predicted by both IRI01-corr and IRI-2001 options of the IRI-2012 model are sometimes higher than the IGS TEC values observed at Chumphon. In addition, we study the diurnal variations of the scale height computed from NeQuick topside formulation (H sc ), hmF2 and foF2 parameters. The correlation of H sc with the parameters hmF2 and the bottomside thickness parameter of NeQuick model (B2 bot ). The computed H sc values during daytime are lower than those during nighttime and they show non-linear correlations with hmF2 and B2 bot . The main cause of these discrepancies are possibly due to the B2 bot expressions used to compute the H sc .
Citation
Advances in Space Research, 60(2), 206-221, 2017
Subjects

Equatorial latitude

IRI-2012 model

NeQuick model

Scale height

Topside electron dens...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback