A Microfluidic Paper-based Analytical Device for Simultaneous Measurement of Albumin, Creatinine and Uric Acid in Urine based on Standard Addition Method

Author(s)
Wisaichon, Wannakan
Choengchan, Nathawut
Praditweangkum, Wiboon
Date Issued
January 3, 2024
Type
Article
DOI
10.55003/cast.2023.259364
Abstract
This work describes a simple method for the simultaneous measurement of urinary albumin, creatinine and uric acid using a standard addition approach on a microfluidic paper-based analytical device (µPAD). Hydrophobic barrier of the µPAD was created by stamping indelible ink onto a filter paper. The µPAD was designed with a flower-liked configuration. After aliquoting urine to a central sample zone, the sample flowed to ten surrounding channels, namely “the inner channels”, where the blank (water) or standard solutions had been added. The inner channels were connected to circular reagent zones where reagents had been immobilized. Tetrabromophenolphthalein ethyl ester, alkaline picrate, and a mixed solution of ferric chloride and ferric cyanide were used as the chromogenic reagents for the colorimetric detections of albumin, creatinine, and uric acid, respectively. Each reagent zone was linked with a circular detection zone through a second channel, namely “the outer channels”. The blue-, orange-and greenish-blue colored products were observed in the detection zones for the measurement of albumin, creatinine, and uric acid, correspondingly. A digital image of the µPAD was captured with a mobile phone. The color intensities were evaluated by ImageJ™ and were employed for the quantitative analyses. The standard addition calibrations were found to be linear (r2 > 0.99) for the spiked analyte concentrations up to 100 mg L-1 albumin, 1000 mg L-1 creatinine, and 50 mg dL-1 uric acid. The paper platform provided high precision (RSD < 5 %) and good analytical recovery (91.8-109.7 %). Under paired t-test, the results obtained by the developed µPAD and the validating methods were not significantly different at 95 % confidence (albumin: tstat =-0.130, tcri = 3.182, creatinine: tstat =-0.133, tcri = 3.182, and uric acid: tstat = 1.119, tcri = 3.182).
Citation
Current Applied Science and Technology, 24(2), 2024
Subjects

albumin

creatinine

standard addition

uric acid

urine

µPAD

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback