  4. Thermal performance in square-duct heat exchanger with quadruple V-finned twisted tapes
Loading...
Thumbnail Image

Thermal performance in square-duct heat exchanger with quadruple V-finned twisted tapes

Author(s)
Promvonge, Pongjet
Date Issued
December 5, 2015
Type
Article
DOI
10.1016/j.applthermaleng.2015.08.047
Abstract
An investigation on heat transfer augmentation in a square duct with insertion of combined 30°V-fins and quadruple counter-twisted tapes is conducted experimentally. Air as the working fluid enters the test duct having a uniform wall heat-flux condition with Reynolds number ranging from 4000 to 30,000 in the present work. The combined vortex generators (called "V-finned counter-twisted tape") are obtained by incorporating V-fins into the edges of quadruple twisted-tapes having a similar twist ratio of 4. The effect of pertinent V-fin parameters such as four relative fin height, (RB = e/w = 0.16, 0.21, 0.32 and 0.42) and relative fin pitch, (RP = P/w = 4, 8, 12 and 16) at a single fin attack angle, α = 30°on thermal characteristics is examined. The experimental results reveal that the heat transfer and pressure drop in the form of respective Nusselt number and friction factor from the V-finned counter-twisted tape tend to increase with the rise of RB but show the reversing trend with increasing RP. The thermal performance of the V-finned counter-twisted tape is considerably higher than that of the quadruple twisted tapes alone. The V-finned counter-twisted tape with RB = 0.42 and RP = 4 yields the maximum Nusselt number and friction factor but the one with RB = 0.21 and RP = 4 provides the highest thermal performance of about 1.75 at lower Reynolds number.
Citation
Applied Thermal Engineering, 91, 298-307, 2015
Subjects

Fin

Friction factor

Heat transfer

Square-duct heat exch...

Twisted-tape

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback