  4. Effect of Contaminant on Breakdown Characteristics of Mineral Oil and Palm Oil
Loading...
Thumbnail Image

Effect of Contaminant on Breakdown Characteristics of Mineral Oil and Palm Oil

Author(s)
Maneerot, S.
Pattanadech, N.
Date Issued
November 14, 2018
Type
Conference Paper
DOI
10.1109/CMD.2018.8535901
Abstract
This paper details an investigation of the effect of contaminant particles at several different temperatures on the 50 Hz AC breakdown voltage of two dielectric liquids - mineral oil and palm oil. The liquids in the test cell used were comprised of various combinations of the following: a) three particle types (cellulose, spherical iron and copper) of approximately 20 μm diameter, b) three contaminant concentrations i.e.0.001% m/V, 0.003% m/V and 0.005% m/V, and c) four liquid temperatures i.e. 25°C, 50°C, 70°C, and 90°C. were investigated with mushroom shaped electrodes in accordance with IEC 60156. The results obtained in this test process showed that the presence of the added particles in the tested dielectric liquids consistently provided a reduction in breakdown voltage, and that the reduction factor varied according to particle type, particle concentration, liquid type, and liquid temperature, and on whether they consisted of cellulose insulation material or copper and iron conducting material summarizing the test results, it was shown that higher contaminant concentration produced lower breakdown voltages, that the addition of copper particles had the most significant effect on reducing breakdown strength, and that the greatest reduction of breakdown strength was measured in the contaminated mineral oil test samples at a test temperature of 70°C.
Citation
2018 Condition Monitoring and Diagnosis Cmd 2018 Proceedings, 2018
Subjects

breakdown voltage

contaminant

mineral oil and palm ...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback