Loading...
Investigation on the behavior and harmonic voltage distortion of terminal voltage regulation by static var compensators for a three phase self-exited induction generator
Author(s)
Sawetsakulanond, B.
Date Issued
December 1, 2008
Type
Conference Paper
Abstract
This paper proposes the investigation on the behavior and harmonic voltage distortion of terminal voltage regulation by static var compensators for three phase, 2.2kW, 220/380V, 8.7/5A, 4-poles, self-exited induction generators (SEIG). Consideration of capacitance for the SEIG based on equivalent circuit model under steady - state load conditions and a power flow diagram is given. Two types of a Fixed capacitor, Thyristor controlled reactor (FCTCR) static var compensator are used for terminal voltage regulation. Comparative performance of the SEIG and harmonic voltage distortion under dynamic and steady-state operation with pure resistive is given. Research results can be guidelines for the development of effective wind induction generators for electricity generation system. © 2008 IEEE.
Citation
2008 IEEE International Conference on Sustainable Energy Technologies Icset 2008, 483-488, 2008
