Effect of twin delta-winged twisted-tape on thermal performance of heat exchanger tube

Author(s)
Eiamsa-Ard, Smith
Nuntadusit, Chayut
Promvonge, Pongjet
Date Issued
December 8, 2013
Type
Article
DOI
10.1080/01457632.2013.793112
Abstract
This work aims at studying the effect of twin delta-winged twisted-tape insertion on heat transfer, pressure drop, and thermal performance characteristics of a heat exchanger tube. All twisted tapes used in this work were made of aluminum sheets twisted at a single twist ratio of 3.0. The twin delta wings were formed by extrusion of the tape at the center area at every twist length interval. For comparison, three different arrangements of the twin delta wings were: (1) the wing tips pointing upstream of the flow (TTW-up, twin delta-winged twisted tape in counterflow arrangement), (2) the wing tips pointing downstream of the flow (TTW-down, twin delta-winged twisted tape in co-flow arrangement), and (3) the wing tips pointing opposite direction (TTW-o, opposite winged twisted tape). The wing declination was arranged at an angle of 15° with respect to the tape surface. Effects of three different wing-tip angles of 20°, 40°, and 60° for a constant wing base were examined. The experiments were conducted using water as the test fluid in a uniform-heat-flux tube for Reynolds number between 5000 and 15,000. The results demonstrate that the TTW-up consistently provides greater heat transfer rate, friction factor, and thermal performance factor than the TTW-down and the TTW-o, at a similar condition. In addition, the heat transfer rate increases as the wing-tip angle decreases. Over the range investigated, the TTW-up with wing-tip angle of 20° gives the highest thermal performance factor of 1.26 along with a Nusselt number and friction factor of 2.57 and 8.55 times those of the plain tube. © 2013 Taylor and Francis Group, LLC.
Citation
Heat Transfer Engineering, 34(15), 1278-1288, 2013
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback