Heat transfer augmentation in solar heat exchanger duct with louver-punched V-baffles

Author(s)
Promvonge, Pongjet
Promthaisong, Pitak
Skullong, Sompol
Date Issued
December 1, 2022
Type
Article
DOI
10.1016/j.solener.2022.11.009
Abstract
A vortex generator's ability to create secondary flow and accelerate rapid fluid mixing allows it to effectively improve thermal performance in a solar heat exchanger duct. A newly created louver-punched V-baffle (LPVB) vortex generator was tested experimentally in the current study and the flow and thermal patterns were also investigated using a three-dimensional CFD simulation. The Realizable k–ε turbulence model was utilized in the simulation and the predictions were verified using experimental data and correlations. By directing the impinging air onto the duct's heated surface, the square louver on the baffle served the primary function of reducing pressure drag. Air was used as the test fluid, flowing at Reynolds numbers (Re) from 5300 to 23,000 into the constant heat-fluxed duct. On the heated wall that was set up by letting the V-apex direct upstream, the LPVBs with a 45° attack angle (α) were repeatedly positioned. There were two aspects to the current investigation. First, the optimal relative baffle pitches (PR) and louver angles (β) conditions were determined by looking at the LPVB characteristics, which included four β and three PR at a fixed relative louver size (LR = 0.5) and baffle height (BR = 0.4). Second, three relative louver sizes (LR = 0.3–0.9) were investigated at the optimal PR and β. According to the results, the solid-baffle friction loss is significantly reduced by the LPVB with β > 0° while the heat transfer is slightly lower. In the first part, the LPVB with PR = 1.5, β = 45° has the optimal performance while in the second part, the one with LR = 0.9 yields the greatest performance. A numerical flow model was computed to understand the flow and thermal patterns. The findings were verified using the available measurements, and there is close agreement between the experimental and numerical results.
Citation
Solar Energy, 248, 103-120, 2022
Subjects

Heat transfer

Louvered baffle

Solar air heater

Thermal performance

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback