Study of Problem and Effect Mitigation Technique of Unbalance Capacitance in 500 kV Single Phase Transformers

Author(s)
Suksagoolpanya, Suthat
Pattanadech, Norasage
Date Issued
January 1, 2024
Type
Article
DOI
10.55003/ETH.410108
Abstract
This article presents the study of the effect of unbalanced stray capacitance in single-phase 500 kV power transformers and establishes the mitigation technique. The power transformers were operated in Wang Noi Substation for transmitting the electrical power. There are 3 units of single-phase power transformer. Previously, a transformer of phase B failed after being serviced for several years. Thus, the new power transformer was ordered instead of the failed one. However, once the new system had been operated, the hotspots at the surge arrester of tertiary winding (22 kV) were found and the unbalance of phase voltages was observed, resulting in overvoltage as a root cause of the problem. Once a thorough investigation was done, it was found that there was an effect of unbalanced stray capacitance between tertiary winding and ground core since the new power transformer has some different designs compared with the remaining. Hence, the mitigation technique was performed by adding the capacitor parallel to the tertiary winding until the voltage balance was achieved. Simulation with the PSCAD program was performed to determine the optimum value for additional capacitors, i.e., voltage balance, using an iterative method. In this article, the capacitors used for additional were capacitor voltage transformers, which have been installed. As a result of the troubleshooting, the voltage at the 22 kV bus was more balanced as well as not causing overvoltage, and the hotspots at the surge arrester of tertiary winding were not detected resulting in gaining the stability and reliability of using these transformers.
Citation
Engineering and Technology Horizons, 41(1), 2024
Subjects

Capacitance

Capacitor voltage tra...

Power transformer

Unbalance voltage

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback