Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Investigation on tunnel responses due to adjacent loaded pile by 3D finite element analysis
Loading...
Thumbnail Image

Investigation on tunnel responses due to adjacent loaded pile by 3D finite element analysis

Author(s)
Heama, Narunat
Jongpradist, Pornkasem
Lueprasert, Prateep
Suwansawat, Suchatvee
Date Issued
January 1, 2017
Type
Article
DOI
10.21660/2017.31.6542
Abstract
Underground structures are popularly utilized in urban development, especially tunnels for both transportation and utilities. The interaction problem between existing tunnel and piles from new constructed structures thus becomes unavoidable in dense population area. The tunnel loses its stability if the additional forces and changed diameters (due to adjacent piles under loading) of tunnel lining are drastically high. This depends on many factors, such as the clearance and pile tip level with respect to tunnel position. For preliminary assessment during the first stage of design, it is necessary to estimate this impact. The concept of tunnel protection zone is commonly adopted. However, to establish the tunnel protection zone for adjacent loaded pile, the understanding on this interaction problem is essential. This study analyzes the effect of adjacent pile under loading on the existing tunnel by 3D finite element method. The case study is the tunnel of MRTA project subjected to an adjacent 1 m bored pile under loading with various lengths and clearances. The additional forces (bending moment and axial force) and the tunnel deformations are investigated. The results show that the additional forces and the tunnel deformations decrease when the clearance increase and become insignificantly increasing when the clearance is larger than 3.5 m. The distribution patterns of additional forces and tunnel deformation are similar.
Citation
International Journal of Geomate, 12(31), 63-70, 2017
Subjects

3D FEA

Adjacent pile

Structure forces

Tunnel lining deforma...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback