A double-layered paper-based analytical device for speciation and simultaneous determination of iron in waters within single-shot analysis

Author(s)
Thongchan, Surachet
Sookpotarom, Punyapat
Praditweangkum, Wiboon
Thongyoo, Panumart
Sojic, Neso
Choengchan, Nathawut
Date Issued
August 1, 2025
Type
Article
DOI
10.1016/j.talo.2025.100458
Abstract
This work demonstrates the use of a paper-based analytical device (PAD) for the speciation and the simultaneous determination of iron (Fe) in waters within a single-shot analysis. The PAD is designed as having stacked, double layers viz., the topside and underside layers. Each layer (25 × 25 mm2) consists of a defined circular hydrophilic reservoir (10 mm Ø), situated in the adhesive glue-fabricated hydrophobic zone. Both layers are assembled by a two-sided mounting tape (3.0 mm thickness). The sample is introduced onto the topside reservoir and only Fe (II) reacts specifically with bathophenanthroline (Bphen) to form the stable, red-colored product. Consecutively, the sample flows vertically and exposes the underside reservoir. Then, the PAD is flipped, and the new class of the fluorescein derivative is transferred to the underside reservoir. Fe (III) selectively forms the complex with the fluorophore, and this results in quenching of the green, fluorescent light under UV irradiation. The optical image of each reservoir is captured via a smart phone camera under a light control studio and their color intensities are evaluated by ImageJ™ software. Under the optimal conditions, the calibrations, ranging from 0–0.5 mg L-1 Fe (II) and 0–10 mg L-1 Fe (III) are observed with good linearity (r2 > 0.99). Detection limits (3SD) of 0.02 mg Fe (II) L-1 and 0.21 mg Fe (III) L-1 are achieved. The developed PAD offers good recoveries (94.8–107 %) and high precision (RSD < 4 %). It is also successfully validated against the UV–visible spectrophotometric and the ICP-OES methods. The Fe contents are not significant differences at 95 % confidence under the statistical paired t-test (Fe(II): tcal = -0.28, tcri = 2.45 and Fe (III): tcal = 1.77, tcri = 2.45). Remarkedly, The PAD enables the simultaneous determination of Fe(II) and Fe(III) without cross- reactivity effect.
Citation
Talanta Open, 11, 2025
Subjects

Determination

Iron

Paper-based device

Speciation

Waters

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback