  4. Heat transfer in solar receiver heat exchanger with combined punched-V-ribs and chamfer-V-grooves
Loading...
Thumbnail Image

Heat transfer in solar receiver heat exchanger with combined punched-V-ribs and chamfer-V-grooves

Author(s)
Promvonge, Pongjet
Skullong, Sompol
Date Issued
November 1, 2019
Type
Article
DOI
10.1016/j.ijheatmasstransfer.2019.118486
Abstract
An experimental work has been carried out to investigate the influence of combined turbulence promoters (or turbulators) on forced convection and fluid flow resistance behaviors in a solar air heater duct. Two turbulators included V-ribs with punched holes and chamfered V-grooves were introduced. The V-rib and the V-groove having the attack angle of 45° were mounted repeatedly on the absorber plate with their arrangements for V-tip pointing upstream and pointing downstream. Air as the test fluid flowed into the duct with Reynolds number (Re) ranging from 5300 to 23,000. The rib parameters were three relative rib-pitches (RP = 1.0, 1.5 and 2.0), three inclination angles (β = 45°, 0° and −45°) of rib-punched holes having a single relative rib height or blockage ratio, RB = 0.5. The groove parameters included three relative groove-pitch lengths (RP = 1.0, 1.5 and 2.0) similar to the V-rib case. Influences of this newly designed absorber plate on Nusselt number (Nu) and friction factor (f) have been examined and compared with similar results of the smooth duct alone. The experimental results demonstrated that the combined turbulators at β = 45° and RP = 1.0 provide the maximum Nu and f, especially for the V-up case due to stronger vortex flows and the impinging flows from the punched holes over the absorber plate. Further, a new thermal enhancement factor (TEF) at similar pumping power has been proposed and it indicates that the combined V-up rib-groove with β = 45° and RP = 1.5 has the highest TEF of about 2.47.
Citation
International Journal of Heat and Mass Transfer, 143, 2019
Subjects

Punched-rib

Solar air heater

Thermal performance

V-groove

Vortex generators

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback