Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Performance evaluation using laser doppler vibrometer sensing technique on advanced lead magnesium niobate-lead titanate piezoelectric-material-based microactuator for hard drive head
Loading...
Thumbnail Image

Performance evaluation using laser doppler vibrometer sensing technique on advanced lead magnesium niobate-lead titanate piezoelectric-material-based microactuator for hard drive head

Author(s)
Wattananukulchai, Parinya
Isarakorn, Don
Date Issued
January 1, 2018
Type
Article
DOI
10.18494/SAM.2018.1848
Abstract
This paper presents a microactuator for a dual-stage actuator (DSA) of hard disk drive (HDD) based on a lead magnesium niobate-lead titanate (PMN-PT) piezoelectric material and a comparative evaluation of its performance versus that of a traditional lead zirconate titanate (PZT) microactuator using the laser Doppler vibrometer (LDV) sensing technique. PZT microactuator technology has commonly been implemented in the read/write (R/W) magnetic head of HDD. It has a significant function, that is, it moves the magnetic head rapidly and accurately. In order to achieve both accurate positioning control on data tracks and high-speed access across another data track, advanced high-performance actuators and servo control technologies are necessary. An actuator with a wide stroke travel range is essential for HDD as it gives a high-speed access performance. In this study, we focused on comparing the proposed dual-stage PMN-PT head-based actuator with the existing PZT actuator that were mounted on a commercial head gimbal assembly (HGA) using an LDV to determine whether the proposed device could be a worthy replacement of the traditional PZT microactuator. Our experimental results show that the proposed PMN-PT microactuator provided more than twofold improvement in the stroke travel of the R/W magnetic head. Moreover, its dynamic behavior was suitable for assembling a high-density HDD in the future for big data storage without any needs to redesign the HGA nor to costly invest in new assembling machines in a production line. The comparative data of dynamic and static behaviors of PMN-PT versus PZT obtained in this study may be put to good use by sensor designers. Moreover, for many cyber-physical system designers, our data may make them take interest in PMN-PT as a better-performing sensor and an actuator for their systems.
Citation
Sensors and Materials, 30(10), 2183-2197, 2018
Subjects

DSA

HDD

HGA

PMN-PT

PZT

Resonance

Stroke

TPI

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback