Publication: Fuzzy logic control of a two-output high-frequency series-resonant induction heater
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This paper presents the design and concept of fuzzy logic controller analysis of two-output high-frequency series-resonant induction heater. The fuzzy logic controller is applied for non-linear load and unknown mathematical model as well as this prototype, which is used to control the duty-cycle of power switch to maintain current output. The power of the prototype can be controlled by using 3 branches of full bridge series resonant inverter: one branch for common controlled and others controlled for each independently two output. The power for others can be controlled by the asymmetrical voltage cancellation methodology. © 2014 IEEE.
Description
Keywords
asymmetrical voltage cancellation, fuzzy logic controller, zero-voltage-switching
Citation
2014 11th International Conference on Electrical Engineering Electronics Computer Telecommunications and Information Technology Ecti Con 2014, 2014