Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Thermal effectiveness analysis of heat exchange tube with staggered louver-punched V-baffles
Loading...
Thumbnail Image

Thermal effectiveness analysis of heat exchange tube with staggered louver-punched V-baffles

Author(s)
Promvonge, Pongjet
Jayranaiwachira, Nuthvipa
Promthaisong, Pitak
Nakhchi, Mahdi Erfanian
Skullong, Sompol
Date Issued
December 1, 2024
Type
Article
DOI
10.1016/j.icheatmasstransfer.2024.108052
Abstract
An experiment has been conducted to ascertain the optimal approach for enhancing the convective transmission of heat in a heat exchanger tube by periodically positioning staggered louver-punched V-baffle (SLVB) vortex generators on a perforated tape. The louver-punched V-baffles were staggered and set up with two patterns: V-apex directing upstream (VU) and downstream (VD), and each featured a louver-punched aperture to minimize friction loss. The aim of this work was to rise the thermal effectiveness as well as the Nusselt number ratio (NuR) at optimal effectiveness in order to cut down on overall dimension of heat exchangers. Consequently, the research findings focused on behaviors of heat transmission and frictional loss, incorporating generated entropy, through a variety of Reynolds numbers (Re) spanning 29,270 to 4762. The SLVB elements were designed and placed in VU and VD forms using three relative pitches (PR = 0.5, 1.0, and 1.5) as well as six louver-flapped angles (θ = 0°, 10°, 20°, 30°, 45°, and 90°), all at the same attack angle (α = 52°), a baffle height ratio (BR = 0.3) and a louver size ratio (LR = 0.73). As demonstrated by the experiment, the θ = 20° generated the best heat transfer of all PR values, up to 6.55 times greater than the smooth tube, despite having a lower friction loss than the θ = 0° (solid baffle). At PR = 0.5, θ = 20° and smaller Re, the optimum thermal effectiveness factor (TEF) and NuR values were, respectively, about 2.65 and 6.55 for the VU SLVB and 2.52 and 6.04 for the VD one. It implied that the TEF strategies can be utilized to anticipate the best effectiveness under identical scenarios. Also, correlations for the critical parameters, namely, Nu, f, and TEF, were estimated and documented.
Citation
International Communications in Heat and Mass Transfer, 159, 2024
Subjects

Heat exchanger

Heat transfer

Louver V-baffle

Thermal effectiveness...

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback