Modification of selective electrode based on magnetic molecularly imprinted polymer for bisphenol A determination

Author(s)
Leepheng, Piyawan
Limthin, Dalawan
Onlaor, Korakot
Tunhoo, Benchapol
Phromyothin, Darinee
Thiwawong, Thutiyaporn
Date Issued
June 1, 2021
Type
Article
DOI
10.35848/1347-4065/abf079
Abstract
Selective electrodes were modified by using the magnetic molecularly imprinted polymer (MMIP) technique on a screen-printed electrode (SPE) to detect bisphenol A (BPA). Superparamagnetic iron oxide nanoparticles (SPIONs) greatly enhance electrochemical signals due to their superparamagnetic properties. The SPIONs are non-toxic, biocompatible and highly stable. The SPIONs, especially magnetite (Fe3O4), were synthesized from ferrous chloride and ferric chloride using a chemical co-precipitation method. The crystalline structure of the synthesized SPIONs was obtained by X-ray diffractometer, representing cubic inverse spinel structure like magnetite. The synthesized SPIONs had particle sizes of 9.87 α 2.67 nm, which was confirmed by transmission electron microscope. The magnetic property was measured by a vibrating sample magnetometer, which presented the saturated magnetization, magnetic remanence value and coercivity as 48.76 emu g-1, 0.497 emu g-1 and 6.265 Oe, respectively. The surfaces of modified electrodes were characterized by a scanning electron microscope, which revealed BPA template cavities on the electrode surface. The electrochemical properties were studied by cyclic voltammetry and amperometry. The bisphenol A-magnetic molecularly imprinted polymer electrode (BPA-MMIP/SPE) has a sensitivity of 2.909 with a limit of detection of 2.053 × 10-8 M. The concentration range for BPA detection is 2.5 × 10-8 to 1.00 × 10-4 M, which can be applied to detection in a real sample.
Citation
Japanese Journal of Applied Physics, 60(SC), 2021
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback