Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Electrochemically Non-Enzymatic Urea Estimation in Human Dialysate Waste Using Indirect NiOOH-Urea Oxidation
Loading...
Thumbnail Image

Electrochemically Non-Enzymatic Urea Estimation in Human Dialysate Waste Using Indirect NiOOH-Urea Oxidation

Author(s)
Janyasupab, Metini
Asavakijthananont, Narawee
Chanlek, Narong
Chio-Srichan, Sirinart
Zhang, Yuan
Surareungchai, Werasak
Sommani, Piyanart
Date Issued
January 1, 2023
Type
Article
DOI
10.1149/1945-7111/acd353
Abstract
Non-enzymatic urea detection in human dialysate offers a sustainable and spontaneous platform for advanced analysis and monitoring. This study investigated urea estimation in dialysate by using an indirect urea oxidation of nickel on nitrogen doped carbon with an incorporation of surface roughness (Rf) and double layer current (Idl). Fascinatingly, the second oxidation peak on (reverse) cathodic scan at 0.42 V vs Ag/AgCl in cyclic voltammetry and the first peak of differential pulse voltammetry (DPV) after background subtraction were evidenced to the exploited NiOOH binding with urea, concurrently with the regeneration of Ni(OH)2. In presence of more urea, the decreasing trends of the oxidation peaks in both techniques were observed and capable of determining urea concentrations in human dialysate. In consideration of actual reaction current, the measured total current after background subtraction in fresh simulated dialysate provides the sensitivity of −5.136 × 10−5 A.mM−1 (R2 = 0.998) and limit of detection of 60.2 μM in 1-5 mM linear range. For validation in patients’ dialysate, the total current peak was normalized by Rf and subtracted from Idl, resulting in excellent urea estimation with recovery percentage between 99.18 and 102.68 in comparison to that of clinical standard, offering future prognostic monitoring and wearable artificial kidney.
Citation
Journal of the Electrochemical Society, 170(5), 2023
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback