Publication:
High-voltage high-frequency power supply using a phase-shifted PWM full bridge inverter fed ozone generator with constant applied electrode voltage

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Research Projects

Organizational Units

Journal Issue

Abstract

This paper proposes the high-voltage high-frequency power supply for an ozone generator using a phase-shift pulse width modulation (PWM) full bridge inverter with constant applied electrode voltage. The circuit operation is fully described. The high-frequency transformer and ozone generator mathematical models are also included for preliminarily calculating of instantaneous voltages and currents. The proposed system simulation using the MATLAB/SIMULINK software package is given. In order to ensure that the zero voltage switch (ZVS) is always operated over a certain range of a frequency variation, a series-compensated resonant inductor is included. The advantage of the proposed system is a capability of varying ozone gas production quantity by varying the frequency and phase shift angle of the converter whilst the applied voltage to the electrodes is kept constant. The correctness of the proposed system is verified by both simulation and experimental results. © 2010 IEEE.

Description

Keywords

High-voltage high-frequency power supply, High-voltage high-frequency transformer, Ozone generator, Phase-shifted pwm full bridge inverter

Citation

2010 International Power Electronics Conference Ecce Asia IPEC 2010, 1560-1567, 2010