Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Application of functionalized multi-walled carbon nanotubes supporting cuprous oxide and silver oxide composite catalyst on copper substrate for simultaneous detection of vitamin B2, vitamin B6 and ascorbic acid
Loading...
Thumbnail Image

Application of functionalized multi-walled carbon nanotubes supporting cuprous oxide and silver oxide composite catalyst on copper substrate for simultaneous detection of vitamin B2, vitamin B6 and ascorbic acid

Author(s)
Puangjan, Apinya
Chaiyasith, Suwan
Taweeporngitgul, Wipawee
Keawtep, Jeerunda
Date Issued
July 1, 2017
Type
Article
DOI
10.1016/j.msec.2017.03.040
Abstract
A new electrochemical sensor was fabricated from chemically functionalized multiwall carbon nanotubes and electrochemically deposited cuprous oxide and silver oxide composite over the nanotubes on copper substrate. The structural, functional, morphological, electrical properties and elemental composition of the composite were characterized by X-ray diffractometry, Fourier transform infrared spectroscopy, field transmission electron microscopy, electrochemical impedance spectroscopy and energy dispersive X-ray spectroscopy. The developed sensor exhibited excellent electrochemical catalytic activity toward oxidation of vitamin B2 (VB2), ascorbic acid (AA) and vitamin B6 (VB6). Compared to the performance of simple copper substrate, that of the modified electrode was greatly superior. This can be attributed to its robust structure, excellent conductivity and large surface area. With a simple electrode that relies on linear diffusion at the surface, an electrochemical analytical method may have a selectivity problem, i.e., various species present in the target medium may oxidize or reduce at potentials not very different from each other. The conducting porous layer of our modified electrode alters this diffusion characteristic to one of approximately ‘thin layer’ that facilitates better discrimination between species. In this work, differential pulse voltammetry was used for simultaneous determination of VB2, AA and VB6. The linear ranges were 0.05–1752.65 μM, 0.05–1628.54 μM and 0.02–1056.12 μM, and the detection limits (S/N = 3) were 0.014 μM, 0.011 μM and 0.008 μM, respectively. In addition to its high performance, this inexpensive sensor is perfectly stable for simultaneous determination of these species in real samples.
Citation
Materials Science and Engineering C, 76, 383-397, 2017
Subjects

Ascorbic acid

Copper substrate

Cuprous oxide

Functionalized multiw...

Silver oxide

Vitamin B2

Vitamin B6

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback